6.5 INITIAL OPERATION
6.5.1 Preliminary warnings
- Checking all of the gas pipe joints and make sure that gas reaches the boiler (with the gas cock turned on)
- Make sure that the central heating circuit is completely full and vented. The pressure gauge should indicate
a pressure of between 0.75 and 1 bar.
- Make sure that the boiler is connected to the correct electricity supply.
- Make sure that the air intake and the flue outlet is not blocked.
6.5.2 Domestic hot water service
To turn on the boiler turn the main control switch to the summer set-
ting. The boiler is then ready to supply D.H.W. on demand.
Whenever you turn on any hot tap the boiler fires up automatically.
By means of the D.H.W. temperature selector control knob, any
water temperature of between 35 and 60°C may be selected.
6.5.3 Hot water and central heating service
Set the time clock to position 1 (uppermost) and the room stat (if fitted) to max temp. Then turn the main con-
trol switch to the winter setting. The burner will fire up. By means of
the central heating temperature selector control knob, any water
temperature of between 60 and 85°C may be selected. The boiler
will remain on until the temperature selected on the room thermostat
or on the boiler itself is reached.
Whenever there is a demand for D.H.W. on the central heating set-
ting, the boiler is ready to supply it giving priority to the D.H.W. with
the central heating on standby until the D.H.W. demand ceases.
6.5.4 Turning the boiler off
- Turn the main control switch to the O setting.
- Turn off the gas supply to the boiler.
6.5.5 Appliance safety lock-out
This boiler has a cut-out indicator built in to it. Whenever a malfunction is detected, the boiler switches off
automatically and the indicator lights up (red pilot light).
To restart the boiler press the restart button. The red indicator should go out. If there is air in the system or
the boiler is fired before filling the system fully, the high limit stat will trip. If this occurs there will be no lights
illuminated.The stat will reset itself but will take a minute or so and pressing the reset button will not restart
the boiler until the stat has cooled.
IMPORTANT: Whenever the boiler has been left idle for any length of time, or when a new gas bottle is
installed (propane models), the appliance may switch off due to the presence of air in the pipes. In cases such
as these, the reset button may need to be pressed several times until all the air is expelled.
Position: min. max
Position: min. max
FEB-20E
4
0
3
2
1
bar
0
60
120
100
20
80
40
6
9
6
12
3
1
8
9
5
4
3
2
1
7
CONTROL PANEL.
1.- Programmable timer
2.- Heating temperature and pressure gauge
3.- Central heating temperature selector
4.- Main control switch
5.- D.H.W. temperature selector
6.- Green neon light (boiler ready)
7.- Orange neon light (burner functioning)
8.- Red neon light (boiler locked out)
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

fagor-feb-20e-uk-ecoplus

Suche zurücksetzen

  • Warum geht Brenner nach 1 Std Laufzeit immer aus. Eingereicht am 19-5-2021 08:47

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Fagor FEB-20E UK ECOPLUS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info