21
Installation
Dear Installer
Before you start your installation, please
complete the details BELOW.
If your customer has a problem relating to your
installation they will be able to contact you
easily.
Thank you
Installers Name
Installers Company
Installers Telephone number
You must be aware of the following safety
requirements & regulations
Prior to installation, ensure that the local distribution
conditions (nature of the gas and gas pressure) and the
adjustment of the appliance are compatible.
This appliance shall be installed in accordance with the
regulations in force and only in a well ventilated space.
Read the instructions before installing or using this
appliance.
In the UK :-
The regulations and standards are as follows:-
In your own interest and that of safety, it is law that
all gas appliances be installed by competent persons.
CORGI registered installers undertake to work to safe and
satisfactory standards. Failure to install the appliance
correctly could invalidate any warranty or liability claims
and lead to prosecution. The cooker must be installed in
accordance with
All relevant British Standards / Codes of Practice, in
particular BS 5440 Part 2 2000,
For Natural Gas - BS 6172 : 1990 and BS 6891 : 1998
For LP Gas - BS 5482-1:1994 (when the installation is
in a permanent dwelling), BS 5482-2:1977, (when the
installation is in a caravan or other non permanent
dwelling), or BS 5482-3:1999 , (when the installation is
in a boat).
The Gas Safety (Installation and Use) regulations 1998.
The relevant Building / IEE regulations.
In the Republic of Ireland:-
The installation must be carried out by a Competent
Person and installed in accordance with the current
edition of I.S.813 “Domestic Gas Installations” and the
current Building Regulations. Reference should also be
made to the current ETCI rules for electrical installation.
Provision of Ventilation
This appliance is not connected to a combustion products
evacuation device. Particular attention shall be given to
the relevant requirements regarding ventilation.
In the UK:-
The room containing the cooker should have an air supply
in accordance with BS 5440 Part 2 : 2000. All rooms require
an openable window or equivalent, while some rooms
require a permanent vent in addition to the openable
window. The cooker should not be installed in a bedsitting
room with volume less than 20m3. If it is installed in a
room of volume less than 5m3 an air vent of eff ective area
100cm2 is required; if it is installed in a room of volume
between 5m3 and 10m3, an air vent of eff ective area
50cm2 is required; while if the volume exceeds 11m3, no
air vent is required.
If there are other fuel burning appliances in the same
room, BS 5440 Part 2 : 2000 should be consulted to
determine the requisite air vent requirements.
In the Republic of Ireland:-
Reference should be made to the current edition of IS 813,
which makes clear the conditions that must be met to
demonstrate that suffi cient ventilation is available.
Location of Cooker
The cooker may be installed in a kitchen/kitchen diner but
NOT in a room containing a bath or shower.
NOTE:
An appliance for use on LPG shall not be
installed in a room or internal space below
ground level. e.g. in a basement.
Conversion
All models are supplied set for use on group H natural gas.
A conversion kit for Propane / butane gas is included with
the appliance. See the instructions that are supplied with
the conversion kit. After converting the appliance please
attach the Gas Conversion sticker over the appropriate
area of the data badge, this will identify the gas type the
appliance is now set for.
This appliance is designed for domestic
cooking only. Use for any other purpose
could invalidate any warranty or liability
claim.
21

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Falcon 1092 CT Dual Fuel wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info