SERVICING  WARNING
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
20
The inlet connection on the cooker is ISO 7-1 internal. If you
require a ISO 228-1 connection fi nd the ISO 7-1 to ISO 228-
1 connector in the conversion kit. Apply a suitable thread
sealing compound to the ISO 7-1 end.
Screw the connector into the cooker inlet until it is fi nger
tight. Using two suitable tools, one on the inlet on the cooker
to make sure it is held steady and one on the connector,
tighten the connector into the inlet on the cooker.
Minimum torque 15Nm.
Maximum torque 20Nm
Connect the hose to the connector.
The hose should be fi tted so that both inlet and outlet
connections are vertical so that the hose hangs downwards in
a ‘U’ shape.
For the UK
For Natural Gas the fl exible hose must be in accordance with
B.S.669.
For LP Gas it should be capable of 50mbar pressure, 70C
temperature rise and carry a red stripe, band or label.
If in doubt contact, your supplier.
Because the height of the cooker can be adjusted and each
connection is diff erent it is diffi cult to give precise dimensions.
Ideally the house supply connection should be in the shaded
area shown in the fi gure showing the back of the cooker (‘A in
the fi gure). Alternatively connect from the side.
After completing the gas connection, check the cooker is gas
sound with a pressure test. When checking for gas leaks do
not use washing up liquid - this can corrode. Use a product
specifi cally manufactured for leak detection.
CAUTION: DO NOT USE A FLAME TO CHECK FOR GAS LEAKS
Pressure testing
The gas pressure can be measured at the pressure test point on
the gas connection block. Turn and light one of the hotplate
burners.
For Natural Gas the pressure should be 20mbar.
For Propane the pressure should be 37mbar
Reassemble burner top, making sure it is reassembled in the
correct way on the burner body.
Electrical Connection
This appliance must be installed by a qualifi ed electrician
to comply with the relevant regulations and also the local
electricity supply company requirements.
WARNING: THIS APPLIANCE MUST BE EARTHED
Note
The cooker must be connected to the correct electrical supply
as stated on the voltage label on the cooker, through a suitable
cooker control unit incorporating a double pole switch having
a contact separation of at least 3mm in all poles. This cooker
must not be connected to an ordinary domestic power point.
The total electrical load of the appliance is approximately
7.2kW. The cable size used should be suitable for this load and
comply with all local requirements.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel.
Connect the mains cable to the correct terminals for your
electrical supply type.
Check that the links are correctly fi tted and that
the terminal screws are tight.
Secure the mains cable using the cable clamp.
Current Operated Earth Leakage Breakers
Where the installation is protected by a 30-milliamp sensitivity
residual current device (RCD), the combined use of your
cooker and other domestic appliances may occasionally cause
nuisance tripping. In these instances the cooker circuit may
need to be protected by fi tting a 100mA device. This work
should be carried out by a qualifi ed electrician.
Hotplate
Check each burner in turn. There is a fl ame safety device that
stops the fl ow of gas to the burner if the fl ame goes out. There
is also a spark ignition system that works when the knob is
pressed in.
For each burner, push in and turn the knob to the large fl ame
symbol ( ).
The igniter should spark and light the gas. Keep holding the
knob pressed in to let the gas through to the burner for few
seconds.
If, when you let go of the control knob, the burner goes out,
the safety device has not held in. Turn the control to the off
position and wait one minute, then try again this time holding
in the control knob for slightly longer.
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Falcon De Luxe 1092 Continental wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Falcon De Luxe 1092 Continental

Falcon De Luxe 1092 Continental Bedienungsanleitung - Holländisch - 30 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info