FUMES DISCHARGE (only intended for personnel qualied to assemble the hood)
EXTERNAL EXHAUST HOOD VERSION SUCTION
In this version, the kitchen fumes and vapours are conveyed outside through an exhaust pipe.
The air outlet tting that extends from the upper part of the hood must be connected with the pipe that conducts
the fumes and vapours to an external output.
Do not connect the equipment to discharge pipes of fumes produced from combustion (for example boil-
ers, replaces, etc) and you are to comply with the regulations in force regarding external air discharge.
The fumes outlet pipe must have:
- a diameter not less than that of the hood tting;
- a slight slope downwards (drop) in the horizontal sections to prevent any formation of condensation from owing
back to the hood;
- the minimum required number of bends;
- minimum required length (long pipes with various bends can reduce suction performance of the hood and trigger
vibrations of the check valve).
If the fumes outlet pipe passes through cold environments such as attics, etc., it is possible that water condensation
forms due to sudden changes in temperature. In this case, you are required to insulate the pipes.
The hood supplied with an 800 m
3
/h motor is equipped with a check valve whose function is to prevent external air exchange when the hood is not
operating: refer to the instructions C on page 4 for assembly.
When the kitchen hood is used simultaneously with other appliances that use gas or other fuels, the room must have sucient ventila-
tion, in accordance with regulations in force.
The active carbon lters in this version are to be removed. Refer to the instructions I on page 6 for removal.
Deviation for Germany: when the kitchen hood is used at the same time as appliances that are powered by energy other than electricity, the negative pressure
in the room must not exceed 4 Pa (4 x 10-5 bar).
HOOD VERSION WITH INTERNAL RECIRCULATION FILTERING
In this model, air passes through the active carbon lters to be puried and is then recycled into the kitchen envi-
ronment.
Check that the active carbon lters are assembled onto the hood, if not, install them as indicated in the in-
structions I on page 6.
If the hood is set up with a ltering version, the check valve must not be assembled: remove it if it is on the air outlet
tting of the motor (carry out operations described in the instructions
C on page 4 in reverse order).
ASSEMBLY INSTRUCTIONS (only intended for personnel qualied to assemble the hood)
Phase
A page 4
•Place the support bar (S) on the installation wall at a height (H) from the cooker indicated in the gure (Fig.
1
).
•Use a spirit level to check the horizontal alignment and draw 2 marks at each end of the support bar, this is where the holes will be drilled (Fig.
2
-
3
).
•Drill the holes, insert 2 expansion plugs (ø 8mm) and fasten the bar with the relative screws (V1) (Fig.
4
).
The xing kit (screws, plugs, and brackets) supplied with the hood can only be used on masonry walls: should it be necessary to
install the hood onto walls in a dierent material, assess other xing systems keeping the wall resistance and weight of the hood in mind
(indicated on page 2).
Phase B page 4
•Hook the hood onto the support bar (Fig.
1
).
•Adjust the alignment of the hood by using the xing screws (Fig.
2
). The upper screw (B) adjusts the distance from the wall, the lower one (C)
adjusts vertical scrolling.
•To prevent the hood from falling due to a pressure below, fasten it to the wall with expansion plugs and relative screws (V2) using the appropriate
holes on the back of the hood (Fig.
3
).
Phase
C and D page 4
EXTERNAL EXHAUST HOOD VERSION SUCTION
•If you wish, install the check valve (M) as indicated in gure C.
•Connect the air outlet connection of the hood to the external discharge with a suitable pipe.
HOOD VERSION WITH INTERNAL RECIRCULATION FILTERING
•Check that the active carbon lters are assembled onto the hood, if not, install them as indicated in the instructions I on page 6.
•If installed, remove the check valve assembled on the hood air outlet tting (carry out the instructions described C on page 4 in reverse order).
Phase E page 5
•Insert the extension (H) in the chimney (G) (Fig.
1
) and fasten the assembly to the body of the hood using screws (V3)(Fig.
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Falmec Exploit Top - wall wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.