784937
5
Zoom out
Zoom in
Vorherige Seite
1/24
Nächste Seite
ladders, water pipes, or other metal within
1.5 m of the spa to comply with local
requirements. The means of disconnection
must be readily accessible, but must be
installed at least 1.5 m from the spa.
Your spa requires a suitably rated circuit
breaker to open all ungrounded supply
conductors.
Your spa must have a ground fault circuit
interrupter in an electrical subpanel.
Before each use of the spa and with the
unit operating, push the TEST button on
the breaker. The switch should click over
to the “Trip” position. Wait 30 seconds
and reset the GFCI breaker by switching
it completely off and then completely
on. The switch should then stay on. If
the interrupter does not perform in this
manner, it is an indication of an electrical
malfunction and the possibility of an
electric shock. Disconnect the power until
the fault has been identified and corrected.
IMPORTANT: Failure to wait 30 seconds
before resetting the GFCI may cause
the spa’s Power Indicator (on the control
panel) to blink. If this occurs, repeat the
GFCI test procedure.
DANGER: RISK OF
ELECTRICAL SHOCK
Install spa at least 1.5 m from all metal
surfaces. A spa may be installed within
5 feet of a metal surface if each metal
surface is permanently connected by a
minimum 6 mm² solid copper conductor
attached to the wire ground connector on
the terminal box that is provided for this
purpose if in accordance with your national
electrical code.
Do not permit any electrical appliances,
such as a light, telephone, radio, or
television within 1.5 m of a spa. Failure
to maintain a safe distance may result in
death or serious personal injury due to
electrocution if the appliance should fall
into the spa.
Install your spa in such a way that
drainage is away from the electrical
compartment and from all electrical
components.
DO:
Be sure your spa is connected to the
power supply correctly - use a licensed
electrical contractor.
Disconnect the spa from the power supply
before draining the spa or servicing the
electrical components.
Test the Ground Fault Circuit Interrupter(s)
before each use.
DON’T:
Use the spa with the equipment
compartment door removed.
Place electrical appliances within 1.5 m of
the spa.
Use an extension cord to connect the spa
to its power source. The cord may not be
properly grounded and the connection is
a shock hazard. An extension cord may
cause a voltage drop, which will cause
overheating of the jet pump motor and
motor damage.
Attempt to open the electrical control box.
There are no user serviceable parts inside.
RISKS TO AVOID
DANGER: RISK OF INJURY
DO NOT sit in the filter compartment area.
Sitting in this area can cause:
a) Restriction of Filter Pump suction/
vacuum
b) Damage to components
Both can result in bodily harm. Should
damage occur to components in this area,
replace immediately!
To reduce the risk of injury to persons, DO
NOT remove floating weir, basket, and filter
located in the filter compartment while the
spa is running.
The suction fittings in the spa are sized to
match the specific water flow created by
SAFETY INFORMATION
2
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Fantasy Aspire 2019 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info