to the instructions represented in fig. 2. Place the
compressor on a flat surface or at a maximum slope
of10°(fig.3),inawellventilatedarea,protected
against atmospheric factors and not in explosive
surroundings.Ifthesurfaceareaisslopingand
smooth,makesurethatthecompressorwillnot
movewheninoperation.Ifthesurfaceareaisa
boardorashelfofabookcase,justmakesurethat
they cannot fall down by securing them properly.
Forproperventilationandeffectivecooling,itis
important that the compressor is positioned at least
100 cm from the wall (fig. 4).
Make sure that the compressor is
transported in the right way, do not turn it
upside down and don’t lift it with hooks
or ropes (fig. 5-6).
Filling the compressor with oil.
Your compressor is supplied with oil which is
already included in the carter.
Beforeuse,removethetransportcaponthecarter
(12),andreplaceitbytheregularoilcap(fig7).
Beforeuse,ensurethatoillevelissufficient.
This can be checked by checking the oil
inspectionglass(13).Whencompressorisplaced
horizontally,theoillevelshallreachtheredmark.
Installing the air filters.
Remove the transport lids and replace them with
the supplied air filters before using the compressor.
Starting up
• Checkwhetherthemainsvoltagecorresponds
to that indicated on the electrical specification
plate(fig.10),thepermittedtolerancerange
should be within 5%.
• Presstheswitch(3)situatedontheupperpart
intothe“0”positionaccordingtothepressure
regulator type fitted on the device (fig. 11).
• Puttheplugintheplugsocket(fig.9)andstart
the compressor up by putting the switch(3)
ofthepressureregulatorinthe“I”position.
The operation of the compressor is fully
automatic. The pressure regulator will stop
the compressor when the maximum value has
been reached and start it up when the pressure
drops below the minimum value. Normally
the difference in pressure is approx. 2 Bar/29
psi between the maximum and the minimum
value.Forinstance-Thecompressorwillstop
when it reaches 8 Bar (116 psi) (this is the
maximum operating pressure) and will start
up automatically when the pressure within the
tank has dropped to 6 Bar (87 psi).
The head/cylinder/transmission pipe
assembly may reach high temperatures,
so take care when working close to these
parts and do not touch them to avoid
burns (fig. 12 - 13).
Adjusting the operating pressure
Fig. 14
Itisnotnecessarycontinuouslytousethe
maximumoperatingpressure,thecompressed-air
toolsoftenrequirelesspressure.Withregardto
compressors supplied with a pressure reduction
valve it is necessary to set the operating pressure
properly.
Itispossibletosettheoperatingpressureby
using the turning knob(5) on the reduction valve.
• Byturningclockwise,thepressurewillbe
increased.
• Byturninganti-clockwise,thepressurewillbe
reduced.
The compressor has two pressure gauges and
onepointtoconnectanairhose:
• Pressuregauge(7):Thepressureofthisoutlet
can be regulated with help of the reduction
valve (5).
• Pressuregauge(8):tankpressure
Hintsforaccurateadjustmentofthepressure
regulation:
• Turntheturningknob(5)anti-clockwisetill
pressure is fully released
• Connecttheairtoolyouwanttousetothe
quick coupler (6)
• Activatetheairtoolshortly,sothepressure
gauge (7) will show the right pressure level
• Turntheturningknob(5)clockwise,tillthe
pressure gauge (7) shows the pressure level
you need
• Yourairtoolisnowreadytouse.
Note:whennotconnectinganairtoolwhile
adjustingthepressure,itmightoccurthepressure
gauge (7) is not reacting accurately on the
pressure drop.
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ferm CRM1045 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info