465140
7
Zoom out
Zoom in
Vorherige Seite
1/36
Nächste Seite
EN
7
Ferm
ropes (fig. 5-6).
Starting up
Check whether the mains voltage corresponds •
to that indicated on the electrical specification
plate (fig. 10), the permitted tolerance range
should be within 5%.
Press the switch situated on the upper part •
into the “0” position according to the pressure
regulator type fitted on the device (fig. 11).
Put the plug in the plug socket (fig. 9) and start •
the compressor up by putting the switch of the
pressure regulator in the “I” position. The
operation of the compressor is fully automatic.
The pressure regulator will stop the
compressor when the maximum value has
been reached and start it up when the
pressure drops below the minimum value.
Normally the difference in pressure is approx.
2 Bar/29 psi between the maximum and the
minimum value. For instance - The
compressor will stop when it reaches 8 Bar
(116 psi) (this is the maximum operating
pressure) and will start up automatically when
the pressure within the tank has dropped to 6
Bar (87 psi).
The head/cylinder/transmission pipe
assembly may reach high temperatures,
so take care when working close to these
parts and do not touch them to avoid
burns (fig. 12 - 13).
Adjusting the operating pressure
Fig. 14
It is not necessary continuously to use the
maximum operating pressure, the compressed-air
tools often require less pressure. With regard to
compressors supplied with a pressure reduction
valve it is necessary to set the operating pressure
properly.
It is possible to set the operating pressure by using
the turning knob on the reduction valve.
By turning clockwise, the pressure will be •
increased.
By turning anti-clockwise, the pressure will be •
reduced.
The compressor has two pressure gauges and
two points to connect an air hose:
Pressure gauge on the left: pressure on left •
outlet. The pressure of left this outlet can be
regulated with help of the reduction valve.
Pressure gauge on the right: tank pressure + •
pressure on right outlet
The set pressure can be locked by turning the ring
under the turning knob in the opposite direction
from the turning knob thereby fixing the turning
knob. The set pressure is visible on the
manometer of the reduction valve.
4. Maintenance
Make sure that the plug is removed from
the mains when carrying out maintenance
work on the motor.
The machines have been designed to operate
over a long period of time with a minimum of
maintenance. Continuous satisfactory operation
depends upon proper machine care and regular
cleaning. Before interfering in any way whatsoever
with the compressor, please make sure that:
The general line switch is in the “0” position.•
The pressure regulator and the switches on •
the switch board are switched off in the “0”
position.
The air tank is fully decompressed.•
Malfunction
Should the machine fail to function correctly, a
number of possible causes and the appropriate
solutions are given below:
Air loss
May be caused by a poor seal of a connection.•
Check all connections by wetting them •
with soap and water.
The compressor runs but does not compress
Fig. 19
May be caused by the valves (C-C2) or a •
gasket (B1-B2) being broken.
Replace the damaged part.•
The compressor will not start
If the compressor is difficult to start, check:•
whether the voltage of the mains •
corresponds to that on the specification
plate (fig. 10)
whether electrical extension cables are •
being used with a faulty core or length.
whether the operating environment is too •
cold (below 0°C).
whether there is electricity supply (plug •
properly connected, magneto-thermal
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ferm FCO-1524E - CRM1037 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info