62 Ferm
SAFETY AND OPERATING
INSTRUCTIONS
High pressure cleaner FHPW-250
THE NUMBERS IN THE FOLLOWING TEXT
CORRESPOND WITH THE PICTURES AT PAGE 2.
Always read the instruction for electrical products
carefully before use. It will help you understand
your product more easily and avoid unnecessary risks.Keep
this instruction manual in a safe place for future use.
CONTENTS:
1. Machine data
2. Safety instructions
3. Assembly
4. Use
5. Service & maintenance
1. MACHINE DATA
INTRODUCTION
The high pressure cleaner FHPW-250 is quick and
efficient for cleaning vehicles, machines, boats, buildings,
etc., by the removal of stubborn dirt using clean water
and chemical detergents.When using chemical
detergents, only use biodegradable types.
Only clean vehicle engines in areas in which suitable oil
traps are installed.
TECHNICAL SPECIFICATION
CONTENTS OF PACKING
• High pressure cleaner
• Hose
• Trigger
• Lance holder
• Hose handle
• Lance extension
• Lance adjustable nozzle
• Detergent spray attachment
• Safety and operating instructions
• Warranty card
FEATURES
Fig. 1
1. Water outlet
2. Water inlet with filter
3. Main switch
4. Adjustable spray nozzle
5. Lance extension
6. Trigger with lock mechanism
7. High pressure hose
8. Detergent spray attachment
9. Lance holder
10. Hose handle
2. SAFETY INSTRUCTIONS
EXPLANATION OF SYMBOLS
In this manual and/or on the machine the following
symbols are used:
Read instructions carefully
In accordance with essential applicable safety
standards of European directives
Denotes risk of personal injury, loss of life or
damage to the tool in case of non-observance of
the instructions in this manual.
Indicates electrical shock hazard.
Immediately unplug the plug from the mains
electricity in the case that the cord gets damaged
and during maintenance
Faulty and/or discarded electrical or electronic
apparatus have to be collected at the appropriate
recycling locations.
DO NOT direct the water jet towards
people or animals.DO NOT direct the
water jet towards the unit itself, electrical
parts or towards other electrical
SAFETY INSTRUCTIONS
When using electric machines always observe the safety
regulations applicable in your country to reduce the risk
of fire, electric shock and personal injury. Read the
following safety instructions and also the enclosed safety
instructions.
Keep these instructions in a safe place!
ELECTRICAL SAFETY
• Always check if your mains voltage corresponds with
the value on the type plate.
• When replacing old cables or plugs:
Throw away old cables or plugs immediately as soon
as new ones have replaced these. It is dangerous to
put the plug of a loose cable into the socket outlet.
• When using extension cables:
Only use an approved extension cable that is suitable
Model | FHPW-250
Art. nr. | GRM1008
Voltage | AC 230 V
Input power | 1900 W
Working pressure | 110 bar
Max. working pressure | 200 bar
Max. water temperature | 50º C
Working flow rate | 6.01 l/min
Hose length | 5 m
Weight | 16 Kg
Dimensions | 52 x 52 x 36 cm
Lpa (sound pressure level) | 83.5 dB (A)
Vibration level | 1.0 m/s
2
Ferm 3
SPARE PARTS LIST FHPW-250
REF NR DESCRIPTION POSITION
501094 FILTER 1
501096 VALVE SET 2
800035 CONDENSATOR 35UF 3
501097 MAIN SWITCH 4
501102 HOSE 5
501095 WHEEL 6
501104 HANDLE 7
501099 TRIGGER 8
501100 LANCE EXTENSION 9
501101 LANCE ADJUSTABLE NOZZLE 10