619021
10
Zoom out
Zoom in
Vorherige Seite
1/38
Nächste Seite
10
EnergyTop B80 / EnergyTop B125 / EnergyTop B160 / EnergyTop B250
Nr.
PARAMETERMENU Geadviseerde instellingen Alternatief instelbaar: Ingestelde waarde:
P01 Instelling cv-drukmeting .......................................... 00 = cv-druksensor ........... 01 (niet instellen) ................................................
P02 Afstemming van de print op toesteltype ................ 01 (moet 01 zijn) ................ 1-6 Zie blz. 15 en 16 .........
P03 Minimum toerental ventilator ................................... 01 (=50Hz) ........................ 0-255 (4 = 65)Hz .....................................
P04 Ontsteekniveau (in percentage van maximum) ..... 40 % .................................. 0-100 %
..................................................................................................
P05 Ventilatortoerental tijdens standby ......................... 00 Hz ................................. 0-255 Hz .........................................................
P06 Instelling blokkeren zomerstand ............................. - - ..................................... - - (niet instellen) ........................................
P07 Cv-stijgingslijn (cv-aanvoertemperatuur) .............. 02
o
C .................................. 1-10
o
C ..........................................................
P08 Minimum startpunt cv-stijgingslijn ........................... 20
o
C .................................. 20-80
o
C ..........................................................
P09 Nadraaitijd pomp (na vraag kamerthermostaat) ..... 15 minuten ......................... 0-255 minuten .................................................
P 10 Wachttijd na cv-gebruik (voor cv) ......................... 04 minuten ......................... 0-10 minuten .................................................
P11 Begrenzing capaciteitsinstelling voor cv ............... 100 % .................................. 0-100 % ..........................................................
P12 Instelling tijdelijk/continu nadraaien cv-pomp .......... 00 ( = zie parameter 09) ..... 01 = continu nadraaien ......................................
P13 Maximum toerental modulerende pomp (n.v.t.) ...... 100 % .................................. n.v.t. ..............................................................
P14 Temperatuur pompstop tijdens nadraaien (aanvoer) . 20
o
C ..................................... 0-100
o
C ..........................................................
P15 Begrenzing maximale instelling cv-setpoint ........... 90
o
C .................................. 20-90
o
C ..........................................................
P 16 Nadraaitijd pomp (na tapwatervraag) .................... 30 seconden ..................... 0-255 seconden ..............................................
P17 Wachttijd na tapwatervraag (voor cv) (“d1”) ........ 120 seconden ..................... 0-255 seconden ..............................................
P18 Maximaal vermogen voor tapwaterbereiding ........ 100 % .................................. 0-100 % ..........................................................
P 19 Begrenzing maximale instelling tapwatersetpoint .. - -
o
C .................................. - - (niet instellen) ........................................
P20 Min. warmhoudtemperatuur cv-wisselaar ............ - -
o
C .................................. - - (niet instellen) ........................................
(in comfortstand)
P21 dT cv-wisselaar in comfortstand .......................... - -
o
C .................................. - - (niet instellen) ........................................
P 22 Pompregel-dT aanvoer- en retoursensor (n.v.t.) ... 30
o
C .................................. 0-60
o
C ..........................................................
P 23 Max. dT tussen aanvoer- en retoursensor ........... 30
o
C .................................. 0-60
o
C ..........................................................
(regeling brander)
P24 Instelling laagste uitschakeldruk cv-druksensor .... - - ..................................... - - (niet instellen) ........................................
P25 Niet van toepassing ............................................... - - ..................................... - - (niet instellen) ........................................
P26 Niet van toepassing ............................................... - - ..................................... - - (niet instellen) ........................................
P27 Niet van toepassing ............................................... 00 ..................................... 01 ..............................................................
P 28 Instelling t.b.v. 230V voedingsfrequentie ............... - - = 50Hz .......................... - - (niet instellen) ........................................
Nr. Parameter-functie: Instellingen Alternatief instelbaar: Ingestelde waarde:
P01 CV-vraag aansturing ............................................. 0 (aan/uit-regeling) .......... 1 = OpenTherm WA
............................................................................... ..................................... 2 = 0-10Vdc temperatuur-aansturing
............................................................................... ..................................... 3 = 0-10Vdc vermogens-aansturing ....................
P02 CV-cascadesensor selectie .................................. 0 (uit) ............................... 1 (aan) ..............................................................
P03 Boiler-selectie ........................................................ 0 (aan) ............................. 1 (uit) ..............................................................
P04 Tijd-instelling driewegklep ...................................... 0 (seconden) ................... ..............................................................
P05 Cascade wachttijd (seconden) ............................. 0 (seconden) ................... ..............................................................
P06 Cascade wachttijd (minuten) ................................. 1 (minuten) ...................... ..............................................................
P07 Cascade niveau -toevoeging ................................. 15 (%) ............................... ..............................................................
P08 Cascade afval-niveau (in %) ................................. 5 (%) ............................... ..............................................................
P09 Open verdeler selectie .......................................... 0 (niet aanwezig) ............ 1 (aanwezig) .......................................................
P 10 Selectie water bijvullen .......................................... 0 (uit) ............................... 1 (aan) ..............................................................
P 11 Driewegklep lokatie selectie .................................. 0 (intern) .......................... 1 (extern) .............................................................
P12 0-10Vdc CV-uit temperatuur-regeling .................... 25 (Volt/10) ........................ ..............................................................
P13 0-10Vdc CV-aan temperatuur-regeling ................. 30 (V olt/10) ........................ ..............................................................
P 14 0-10Vdc max. voltage temperatuur-regeling ......... 100 (Volt/10) ........................ ..............................................................
P 15 0-10Vdc min. temperatuur-regeling ....................... 20 (
o
C) ............................... ..............................................................
P 16 0-10Vdc max. temperatuur-regeling ...................... 90 (
o
C) ............................... ..............................................................
P17 0-10Vdc CV-uit output-regeling ............................. 25 (Volt/10) ........................ ..............................................................
P18 0-10Vdc CV-aan output-regeling ........................... 30 (Volt/10) ........................ ..............................................................
P 19 0-10Vdc max. voltage output-regeling .................. 100 (V olt/10) ........................ ..............................................................
P20 0-10Vdc min. output output-regeling ..................... 0 (%) ............................... ..............................................................
P 21 0-10Vdc max. output output-regeling .................... 100 (%) ............................... ..............................................................
3.5 SYSTEEM-menu
Druk 10 seconden op de zomer-/ wintertoets .
Het SYSTEEM-menu is nu actief.
Druk op de LINKER
of en doorloop het
SYSTEEM-menu tot de te wijzigen parameter.
Wijzig evt. met de RECHTER en de waarde.
De ingestelde waarde wordt direct opgeslagen
Druk de zomer- /wintertoets
in om terug te keren
naar het SYSTEEM-menu. Druk 10 sec. op de zomer- /
wintertoets
om uit het SYSTEEM-menu te gaan.
Onderstaande PARAMETER-menu is een deel van het SERVICE-menu
0-10Vdc input Setpoint (
o
C) Vermogen (%)
(bij P02 = 2) (bij P02 = 3)
00 00
o
C Brander UIT
01 00
o
C Brander UIT
02 00
o
C Brander UIT
03 20
o
C Brander AAN: 035%
04 33
o
C Brander AAN: 044%
05 43
o
C Brander AAN: 054%
06 53
o
C Brander AAN: 064%
07 63
o
C Brander AAN: 073%
08 73
o
C Brander AAN: 083%
09 83
o
C Brander AAN: 093%
10 90
o
C Brander AAN: 100%
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Ferroli EnergyTop B160 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Ferroli EnergyTop B160

Ferroli EnergyTop B160 Bedienungsanleitung - Holländisch - 2 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info