4.2 TROUBLESHOOTING
Troubleshooting and eventual control and/or maintenance operations must be performed by
qualified personnel.
For servicing the refrigerating circuit of the machine, contact a refrigeration engineer.
TROUBLE POSSIBLE CAUSE AND REMEDY
Illuminated switch of the control
panel off.
1. Check the mains for presence of voltage.
2. Check cabling.
The compressor doesn’t start. 1. Check the protection fuse, and eventually replace it (aM delayed type).
2. Check cabling and the timing card.
3. Activation of the internal thermal protection; wait 1 hour and check. If the
fault persists, stop the dryer and call a refrigeration engineer.
4. Check the electrical components of the compressor.
5. Short circuit in the compressor. Replace it.
The fan is not turning. 1. Check cabling.
2. Defective or burned out thermostat (350 ÷ 750 l/min dryers only), stop the
dryer and contact a refrigeration engineer.
3. Defective or burned out fan pressure switch, stop the dryer and contact a
refrigeration engineer.
4. Short circuit in the fan. Replace it.
Condensate drain absent (no
water nor air).
1. Check cabling.
2. Pre-filter of the drainage system dirty, clean it.
3. The coil of the drainage solenoid vale is burned out, replace it.
4. Drainage solenoid valve clogged/jammed, clean or replace it.
5. Check the electronic card, if the trouble persists, replace it.
6. The temperature on the display of the control panel is lower then the nominal
value, see specific section.
Air flows continuously through
the condensate drainage.
1. Drainage solenoid valve jammed, clean or replace it.
2. Verify the condensate drainage times set on the timing card.
3. Check the timing card, if the trouble persists, replace it.
Water in the line tubing
downstream the dryer.
1. Dryer non operating, start it up.
2. The by-pass system (if present) is open, close it.
3. Condensate drainage absent, see specific section.
4. The temperature on the display of the control panel is higher then the
nominal value, see specific section.
The temperature on the display
of the control panel is higher
then the nominal value.
1. Check the compressed air inlet/outlet for proper connection.
2. The compressor doesn’t start, see specific section.
3. The fan doesn’t turn, see specific section.
4. The flow rate and/or temperature of the air entering the dryer are higher then
the nominal values, restore the nominal conditions.
5. The ambient temperature is higher than the nominal values, restore the
nominal conditions.
6. The condenser is dirty, clean it.
7. Condensate drain absent (no water nor air), see specific section.
8. Check the control probe in the evaporator for improper positioning or fault.
9. Gas leakage in the refrigerating circuit. Stop the dryer and call a refrigeration
engineer.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Finicompressors Artic 134-12 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Finicompressors Artic 134-12

Finicompressors Artic 134-12 Bedienungsanleitung - Deutsch - 11 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info