IMPORT ANT! PLEASE READ CAREFULL Y AND SA VE.
This user’ s manual contains important information about your Smoke
Alarm’ s operation. If you ar e installing this Smoke Alarm for use by
others, you must leave this manual—or a copy of it—with the end user .
USER’S MANUAL
Printed in Mexico
M08-0466-156401 K1 01/17
© 2017 BRK Brands, Inc. All rights reserved. Distributed by BRK Brands, Inc.
BRK Brands, Inc. is a subsidiary of Newell Brands Inc. (NYSE:NWL) • First
Alert® is register ed trademark of The First Alert T rust • 3901 Liberty Street,
Aurora, IL 60504-8122 • Consumer Affairs: (800) 323-9005 •
www .firstalert.com • www.brkelectr onics.com
INTRODUCTION
Thank you for choosing First Alert® for your Smoke Alarm needs. Y ou
have purchased a state of the art Smoke Alarm designed to pr ovide you
with early warning of a fire. Please take the time to read this manual and
make the Smoke Alarm an integral part of your family’ s safety plan.
Key Features of the P1210 Smoke Alarm:
Photoelectric Sensing Technology: Photoelectric Sensors are generally
more sensitive than ionization sensors in detecting smoldering fir es
which commonly occur in couches or bedding.
OptiPath 360 T echnology™: Patented technology pr ovides 360° of
direct access to the smoke sensor .
Single T est/Silence Button: Allows you to test the Alarm or silence
nuisance alarms. T esting the Alarm assures you that the unit is functioning
correctly and r eady to protect you and your family . The Alarm can be
silenced for up to 9 minutes in the event of a nuisance alarm.
10 Y ear End of Life Indicator: 3 horn pulses every 43 seconds alerts
you that the unit must be replaced.
Local Alarm Memory: Green LED flashes 3 times every 43 seconds for
24 hours. After 24 hours the unit will chirp rapidly while the T est button
is pressed. Memory is clear ed when the button is released.
Low battery warning: The Alarm will sound a “chirp” once per minute
when the Smoke Alarm needs to be replaced.
Low battery silence: The Alarm can be silenced for 8 hours.
Red Blinking Power Indicator every 6 minutes: Confirms that the
Smoke Alarm is receiving power .
FIRE SAFETY TIPS
Follow safety rules and prevent hazar dous situations: 1) Use smoking
materials properly . Never smoke in bed. 2) Keep matches or lighters
away from childr en; 3) Store flammable materials in proper containers;
4) Keep electrical appliances in good condition and don’t overload
electrical circuits; 5) Keep stoves, barbecue grills, fir eplaces and chimneys
grease- and debris-fr ee; 6) Never leave anything cooking on the stove
unattended; 7) Keep portable heaters and open flames, like candles, away
from flammable materials; 8) Don’ t let rubbish accumulate.
Keep alarms clean, and test them weekly . Replace alarms immediately
if they are not working pr operly . Smoke Alarms that do not work cannot
alert you to a fire. Keep at least one working fir e extinguisher on every
floor , and an additional one in the kitchen. Have fire escape ladders or
other reliable means of escape fr om an upper floor in case stairs are
blocked.
BEFORE YOU INST ALL THIS SMOKE ALARM
Important! Read “Recommended Locations for Smoke Alarms” and
“Locations to Avoid for Smoke Alarms” befor e beginning. This unit
monitors the air , and when smoke reaches its sensing chamber ,
it alarms. It can give you more time to escape befor e fire spreads.
This unit can ONL Y give an early warning of developing fires if it is
installed, maintained and located where smoke can r each it, and where
all residents can hear it, as described in this manual. This unit will not
sense gas, heat, or flame. It cannot prevent or extinguish fir es.
Understand The Differ ent T ype of Smoke Alarms
Battery powered or electrical? Dif ferent Smoke Alarms provide
differ ent types of protection. See “About Smoke Alarms” for details.
Know Where T o Install Y our Smoke Alarms
Fire Safety Pr ofessionals recommend at least one Smoke Alarm on
every level of your home, in every bedroom, and in every bedr oom
hallway or separate sleeping area. See “Recommended Locations
For Smoke Alarms” and “Locations T o Avoid For Smoke Alarms”
for details.
Know What Smoke Alarms Can and Can’t Do
A Smoke Alarm can help alert you to fire, giving you pr ecious time to
escape. It can only sound an alarm once smoke reaches the sensor .
See “Limitations of Smoke Alarms” for details.
Check Y our Local Building Codes
This Smoke Alarm is designed to be used in a typical single-family
home. It alone will not meet requir ements for boarding houses,
apartment buildings, hotels or motels. See “Special Compliance
Considerations” for details.
HOW TO INST ALL THIS SMOKE ALARM
THE P ARTS OF THIS SMOKE ALARM FOLLOW THESE SIMPLE STEPS
*All First Alert® Smoke Alarms conform to regulatory requirements,
including UL217 and are designed to detect particles of combustion.
Smoke particles of varying number and size are produced in all fires.
Ionization technology is generally more sensitive than photo-
electric technology at detecting small particles, which tend to be
produced in gr eater amounts by flaming fires, which consume
combustible materials rapidly and spread quickly . Sources of
these fires may include paper burning in a wastebasket, or a grease fir e
in the kitchen.
Photoelectric technology is generally more sensitive than ionization
technology at detecting large particles, which tend to be pr oduced
in greater amounts by smoldering fir es, which may smolder for
hours before bursting into flame. Sour ces of these fires may include
cigarettes burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on each
level and in every bedroom of your home.
• Thisunit will notalert hearing impairedresidents.It is recom-
mended that you install special units which use devices like
flashing strobe lights to alert hearing impair ed residents.
• Donot connect thisunit to any otherAlarm or auxiliary
device. It is a single-station unit that cannot be linked to other
devices. Connecting anything else to this unit may prevent it
from working pr operly .
• Unitwill not operate withoutbattery power .TheSmoke Alarm
cannot work until you activate the battery power pack.
• Donot install thisunit over an electricaljunction box.
Aircurrents aroundjunction boxescan preventsmoke from
reaching the sensing chamber and pr event the unit from
alarming. Only AC powered units ar e intended for installation
overjunction boxes.
• Donot stand tooclose to the unitwhen the alarm issounding.
It is loud to wake you in an emergency . Exposure to the horn
at close range may harm your hearing.
• Donot paint over theunit. Paint may clogthe openings tothe
sensing chamber and prevent the unit fr om operating properly .
123
1. Mounting bracket
2. Mounting slots
3. T ur n this way to remove
4. T ur n this way to attach
1. T est/Silence button
2. Dual Power indicator
light and Alarm indicator:
Green LED pr ovides
visual indication of an
Alarm Memory condition;
Red LED provides visual
indication of an Alarm
and Hush modes
IF THIS SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
During an alarm, you will hear a loud, repeating horn pattern:
3 beeps, pause, 3 beeps, pause. The Red LED flashes rapidly .
• Ifthe unit alarmsget everyone out ofthe house immediately.
• Ifthe unit alarmsand you arenot testing theunit, it is warning
you of a potentially dangerous situation that r equires your
immediate attention. NEVER ignore any alarm. Ignoring the
alarmmay resultin injury ordeath.
• Neverremove thebatteries froma battery operatedSmoke Alarm
to stop an unwanted alarm (caused by cooking smoke, etc.).
Removing batteries disables the alarm so it cannot sense smoke,
and removes your pr otection. Instead open a window or fan the
smoke away from the unit. The alarm will r eset automatically .
IF YOU SUSPECT A PROBLEM
Smoke Alarms may not operate properly because of a dead or weak
battery , a build-up of dirt, dust or gr ease on the Smoke Alarm cover ,
or installation in an improper location. Clean the Smoke Alarm as
described in “Regular Maintenance,” and then test the Smok e Alarm
again. If it fails to test properly when you use the test butt on, or if the
problem persists, r eplace the Smoke Alarm immediately .
• Ifyou hear a“chirp” about once aminute, replacethe Smoke
Alarm.
• Ifyou experience frequentnon-emergencyalarms (likethose
caused by cooking smoke), try relocating the Smoke Alarm.
• Ifthe alarm soundswhen no smoke isvisible, try cleaning or
relocating the Smoke Alarm. The cover may be dirty .
• Ifthe alarm doesnot sound during testing,make surethe
power pack activating lever is pushed all the way securely .
Do not try fixing the Alarm yourself – this will void your warranty!
If the Smoke Alarm is still not operating properly , and it is still under
warranty , please see “How to Obtain W arranty Service” in the Limited
W arranty .
SMOKE AND FIRE* ALARM
LIMITED WARRANTY
BRK Brands, Inc., (“BRK”) the maker of First Alert® brand products
warrants that for a period of ten years from the date of pur chase, this
product will be fr ee from defects in material and workmanship. BRK, at
its option, will repair or r eplace this product or any component of the
product found to be defective during the warranty period. Replacement
will be made with a new or remanufactur ed product or component.
If the product is no longer available, r eplacement may be made with a
similar product of equal or gr eater value. This is your exclusive warranty .
This warranty is valid for the original retail pur chaser from the date of
initial retail pur chase and is not transferable. Keep the original sales
receipt. Pr oof of purchase is requir ed to obtain warranty performance.
BRK dealers, service centers, or retail stor es selling BRK products do
not have the right to alter , modify or any way change the terms and
conditions of this warranty .
This warranty does not cover normal wear of parts or damage resulting
from any of the following: negligent use or misuse of the pr oduct, use on
improper voltage or curr ent, use contrary to the operating instructions,
disassembly , r epair or alteration by anyone other than BRK or an
authorized service center . Further , the warranty does not cover Acts of
God, such as fire, flood, hurricanes and tornadoes.
BRK shall not be liable for any incidental or consequential damages
caused by the breach of any expr ess or implied warranty . Except to
the extent prohibited by applicable law , any implied warranty of
merchantability or fitness for a particular purpose is limited in duration
to the duration of the above warranty . Some states, pr ovinces or
jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty
lasts, so the above limitations or exclusion may not apply to you. This
warranty gives you specific legal rights, and you may also have other
rights that vary from state to state or pr ovince to province.
How to Obtain Warranty Service
Service: If service is required, do not return the product to your r etail-
er . In order to obtain warranty service, contact the Consumer Affairs
Division at 1-800-323-9005. T o assist us in serving you, please have the
model number and date of purchase available when calling.
Address: BRK Brands, Inc., 1301 Joe Battle, El Paso, TX 79936
Visit www.firstalert.com for more information.
Disposal: Waste electrical products should not be disposed of with
regular household waste. Please r ecycle where facilities exist. Check
local requir ements for disposal of Li-Ion electronic devices.
The Alarm should be deactivated before disposal.
Y ou can also return your Alarm to us for disposal. For return address
see above. Please include a note confirming the product is being
returned for disposal.
RECOMMENDED LOCA TIONS FOR
SMOKE ALARMS
Installing Smoke Alarms in Single-Family Residences
The National Fire Pr otection Association (NFP A), recommends one
Smoke Alarm on every floor , in every sleeping area, and in every
bedroom. In new construction, the Smoke Alarms must be AC powered
and interconnected. See “Agency Placement Recommendations” for
details. For additional coverage, it is recommended that you install a
Smoke Alarm in all rooms, halls, storage ar eas, finished attics, and
basements, where temperatur es normally remain between 40˚ F (4.4˚ C)
and 100˚ F
(37.8˚ C). Make sure no door or other obstruction could keep smoke
from r eaching the Smoke Alarms.
More specifically , install Smoke Alarms:
•
On every level of your home, including finished attics and basements.
• Inside every bedroom, especially if people sleep with doors closed.
• In the hall near every sleeping area. If your home has multiple
sleeping areas, install a unit in each. If a hall is over 40 feet (12
meters) long, install an Alarm at each end.
• At the top of the first-to-second floor stairway , and at bottom of
basement stairway .
Specific requir ements for Smoke Alarm installation vary from state to
state and from r egion to region. Check with your local Fire Department
for current r equirements in your area. It is recommended AC or AC/DC
units be interconnected for added protection.
AGENCY PLACEMENT RECOMMENDA TIONS
NFP A 72 Chapter 29
“For your information, the National Fire Alarm and Signaling Code ,
NFP A 72, r eads as follows:”
29.5.1* Required Detection.
29.5.1.1* Where r equired by other governing laws, codes, or standards
for a specific type of occupancy , appr oved single and multiple-station
smoke alarms shall be installed as follows:
(1)*In all sleeping rooms and guest r ooms
(2)* Outside of each separate dwelling unit sleeping area, within 21 ft
(6.4 m) of any door to a sleeping room, with the distance measur ed
along a path of travel
(3) On every level of a dwelling unit, including basements
(4) On every level of a residential boar d and care occupancy (small
facility), including basements and excluding crawl spaces and
unfinished attics
(5)*In the living area(s) of a guest suite
(6) In the living area(s) of a r esidential board and care occupancy
(small facility)
(Reprinted with permission from NFP A 72® , National Fire Alarm and
Signaling Code Copyright © 2010 National Fire Pr otection Association,
Quincy , MA 02269. This r eprinted material is not the complete and
official position of the National Fir e Protection Association, on the
refer enced subject which is represented only by the standar d in its
entirety), (National Fir e Alarm and Signaling Code® and NFP A 72® ar e
register ed trademarks of the National Fire Protection Association, Inc.,
Quincy , MA 02269).
California State Fire Marshal (CSFM)
Early warning detection is best achieved by the installation of fire
detection equipment in all rooms and ar eas of the household as follows:
A Smoke Alarm installed in each separate sleeping area (in the vicinity ,
but outside bedrooms), and Heat or Smoke Alarms in the living r ooms,
dining rooms, bedr ooms, kitchens, hallways, finished attics, furnace
rooms, closets, utility and storage r ooms, basements, and attached
garages.
LOCA TIONS TO AVOID FOR SMOKE ALARMS
For best performance, it is recommended you A VOID installing
Smoke Alarms in these areas:
• Where combustion particles ar e produced. Combustion particles
form when something burns. Areas to avoid include poorly ventilated
kitchens, garages, and furnace rooms. Keep units at least 20 feet
(6 meters) from the sour ces of combustion particles (stove, furnace,
water heater , space heater) if possible. In areas where a 20-foot
(6-meter) distance is not possible – in modular , mobile, or smaller
homes, for example – it is recommended the Smoke Alarm be
placed as far from these fuel-burning sources as possible. The
placement recommendations ar e intended to keep these Alarms at
a reasonable distance fr om a fuel-burning source, and thus reduce
“unwanted” alarms. Unwanted alarms can occur if a Smoke Alarm
is placed directly next to a fuel-burning source. V entilate these
areas as much as possible.
• In air streams near kitchens. Air curr ents can draw cooking smoke
into the sensing chamber of a Smoke Alarm near the kitchen.
• In very damp, humid or steamy areas, or dir ectly near bathrooms
with showers. Keep units at least 10 feet (3 meters) away from
showers, saunas, dishwashers, etc.
• Where the temperatur es are regularly below 40˚ F (4.4˚ C) or above
100˚ F (37.8˚ C), including unheated buildings, outdoor rooms,
porches, or unfinished attics or basements.
• In very dusty , dirty , or greasy areas. Do not install a Smoke Alarm
directly over the stove or range. Keep laundry r oom Smoke Alarms
free of dust or lint.
• Near fresh air vents, ceiling fans, or in very drafty ar eas. Drafts can
blow smoke away from the unit, pr eventing it from reaching the
sensing chamber .
• In insect infested areas. Insects can clog openings to the sensing
chamber and cause unwanted alarms.
• Less than 12 inches (305mm) away from fluor escent lights.
Electrical “noise” can interfere with the sensor .
• In “dead air” spaces. “Dead air” spaces may prevent smoke fr om
reaching the Smoke Alarm.
Avoiding Dead Air Spaces
“Dead air” spaces may prevent smoke fr om reaching the Smoke Alarm.
T o avoid dead air spaces, follow the installation recommendations
below .
On ceilings, install Smoke Alarms as close to the center of the ceiling
as possible. If this is not possible, install the Smoke Alarm at least 4
inches (102 mm) from the wall or corner .
For wall mounting (if allowed by building codes), the top edge of
Smoke Alarms should be placed between 4 and 12 inches (102 and
305 mm) from the wall/ceiling line, below typical “dead air” spaces.
On a peaked, gabled, or cathedral ceiling, install the first Smoke
Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured
horizontally . Additional Smoke Alarms may be r equired depending
on the length, angle, etc. of the ceiling’ s slope. Refer to NFP A 72 for
details on requir ements for sloped or peaked ceilings.
SPECIAL COMPLIANCE CONSIDERA TIONS
This Smoke Alarm is suitable for use in apartments, condominiums,
townhouses, hospitals, day care facilities, health car e facilities, boarding
houses, group homes and dormitories pr ovided a primary fire detection
system already exists to meet fir e detection requirements in common
areas like lobbies, hallways, or por ches. Using this Smoke Alarm in
common areas may not pr ovide sufficient warning to all residents or
meet local fire pr otection ordinances/regulations.
This Smoke Alarm alone is not a suitable substitute for complete fire
detection systems in places housing many people—like apartment
buildings, condominiums, hotels, motels, dormitories, hospitals, health
care facilities, nursing homes, day car e facilities, or group homes of any
kind. It is not a suitable substitute for complete fire detection systems
in warehouses, industrial facilities, commer cial buildings, and special-
purpose non-residential buildings which r equire special fire detection
and alarm systems. Depending on the building codes in your area, this
Smoke Alarm may be used to provide additional pr otection in these
facilities.
In new construction, most building codes requir e the use of AC or AC/
DC powered Smoke Alarms only . In existing construction, AC, AC/
DC, or DC powered Smoke Alarms can be used as specified by local
building codes. Refer to NFP A 72 (National Fir e Alarm and Signaling
Code) and NFP A 101 (Life Safety Code), local building codes, or
consult your Fire Department for detailed fir e protection requir ements in
buildings not defined as “households”.
LIMIT A TIONS OF SMOKE ALARMS
Smoke Alarms have played a key role in r educing deaths resulting from
home fires worldwide. However , like any warning device, Smoke Alarms
can only work if they are pr operly located, installed, and maintained,
and if smoke reaches them. They ar e not foolproof.
Smoke alarms may not waken all individuals. Practice the escape
plan at least twice a year , making sure that everyone is involved – from
kids to grandparents. Allow childr en to master fire escape planning and
practice before holding a fir e drill at night when they are sleeping.
If children or others do not r eadily waken to the sound of the Smoke
Alarm, or if there ar e infants or family members with mobility limitations,
make sure that someone is assigned to assist them in fir e drill and in
the event of an emergency . It is recommended that you hold a fire drill
while family members are sleeping in or der to determine their response
to the sound of the Smoke Alarm while sleeping and to determine
whether they may need assistance in the event of an emergency .
Smoke Alarms cannot work without power. Battery operated units
cannot work if the batteries are missing, disconnected or dead, if the
wrong type of batteries ar e used, or if the batteries are not installed
correctly . AC units cannot work if the AC power is cut off for any reason
(open fuse or circuit br eaker , failure along a power line or at a power
station, electrical fire that burns the electrical wires, etc.). If you ar e
concerned about the limitations of battery or AC power , install both
types of units.
Smoke Alarms cannot detect fires if the smoke does not reach
them. Smoke from fir es in chimneys or walls, on roofs, or on the other
side of closed doors may not reach the sensing chamber and set of f the
alarm. That is why one unit should be installed inside each bedroom or
sleeping area—especially if bedr oom or sleeping area doors are closed
at night—and in the hallway between them.
Smoke Alarms may not detect fire on another floor or area of the
home. For example, a stand-alone unit on the second floor may not
detect smoke from a basement fir e until the fire spreads. This may not
give you enough time to escape safely . That is why r ecommended
minimum protection is at least one unit in every sleeping ar ea, and every
bedroom on every level of your home. Even with a unit on every floor ,
stand-alone units may not provide as much pr otection as interconnected
units, especially if the fire starts in a r emote area. Some safety experts
recommend installing inter connected AC powered units with battery
back-up (see “About Smoke Alarms”) or professional fir e detection
systems, so if one unit senses smoke, all units alarm. Interconnected
units may provide earlier warning than stand-alone units since all units
alarm when one detects smoke.
Smoke Alarms may not be heard. Though the alarm horn in this unit
meets or exceeds current standar ds, it may not be heard if: 1) the unit
is located outside a closed or partially closed door , 2) residents recently
consumed alcohol or drugs, 3) the alarm is drowned out by noise fr om
stereo, TV , traffic, air conditioner or other appliances, 4) r esidents are
hearing impaired or sound sleepers. Special purpose units, like those
with visual and audible alarms, should be installed for hearing impaired
residents.
Smoke Alarms may not have time to alarm before the fir e itself
causesdamage, injury ,or death, sincesmoke fromsome firesmay
not reach the unit immediately . Examples of this include persons
smoking in bed, children playing with matches, or fir es caused by
violent explosions resulting fr om escaping gas.
Smoke Alarms are not foolproof. Like any electronic device, Smoke
Alarms are made of components that can wear out or fail at any time.
Y ou must test the unit weekly to ensure your continued pr otection.
Smoke Alarms cannot prevent or extinguish fir es. They are not a
substitute for property or life insurance.
Smoke Alarms have a limited life. The unit should be replaced
immediately if it is not operating properly . Y ou should always replace a
Smoke Alarm after 10 years from date of pur chase. Write the purchase
date on the space provided on back of unit.
First Alert® is a register ed trademark of the First Alert T rust.
456
ABOUT SMOKE ALARMS
Battery (DC) operated Smoke Alarms: Provide pr otection even when
electricity fails, provided the batteries ar e fresh and correctly installed.
Units are easy to install, and do not r equire professional installation.
AC powered Smoke Alarms: Can be interconnected so if one unit
senses smoke, all units alarm. They do not operate if electricity fails.
AC with battery (DC) back-up: will operate if electricity fails, provided
the batteries are fr esh and correctly installed. AC and AC/DC units
must be installed by a qualified electrician.
Smoke Alarms for Solar or Wind Energy users and battery backup
power systems: AC powered Smoke Alarms should only be operated
with true or pure sine wave inverters. Operating this Smoke Alarm with
most battery-powered UPS (uninterruptible power supply) pr oducts or
square wave or “quasi sine wave” inverters will damage the Alarm .
If you are not sur e about your inverter or UPS type, please consult with
the manufacturer to verify .
Smoke Alarms for the hearing impaired: Special purpose Smoke
Alarms should be installed for the hearing impaired. They include a
visual alarm and an audible alarm horn, and meet the requirements of
the Americans With Disabilities Act. Can be interconnected so if one
unit senses smoke, all units alarm.
Smoke alarms are not to be used with detector guards unless the
combination has been evaluated and found suitable for that purpose.
All these Smoke Alarms are designed to pr ovide early warning of fires if
located, installed and cared for as described in the user’ s manual, and
if smoke reaches them. If you ar e unsure which type of Smoke Alarm
to install, refer to Chapter 2 of the National Fir e Protection Association
(NFP A) Standar d 72 (National Fire Alarm and Signaling Code) and
NFP A 101 (Life Safety Code). National Fir e Protection Association,
One Batterymarch Park, Quincy , MA 02269-9101. Local building codes
may also requir e specific units in new construction or in different ar eas
of the home.
BEDROOM
BEDROOM HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
REQUIRED TO MEET
NFP A RECOMMENDA TIONS
RECOMMENDED FOR
ADDITIONAL PROTECTION
BEDROOM
BEDROOM
KITCHEN
LIVING ROOM
DINING ROOM
MUL TI-STOR Y RESIDENCE
SINGLE-STOR Y RESIDENCE, A PA R TMENT ,
MOBILE HOME
KEY :
EXISTING HOMES
SMOKE ALARMS WITH SILENCE
FEA TURES RECOMMENDED FOR
ADDITIONAL PROTECTION
BEDROOM
BEDROOM HALL
LIVING ROOM
FINISHED BASEMENT
BEDROOM
BEDROOM LIVING ROOM
DINING ROOM
MUL TI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APA RTMENT ,
MOBILE HOME
EXISTING HOMES
REQUIRED TO
MEET NFP A
RECOMMENDA TIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
KEY :
INTERCONNECTED AC OR
AC/DC SMOKE ALARMS
BEDROOM
BEDROOM HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
REQUIRED TO MEET
NFP A RECOMMENDA TIONS
RECOMMENDED FOR
ADDITIONAL PROTECTION
BEDROOM
BEDROOM LIVING ROOM
DINING ROOM
MUL TI-STOR Y RESIDENCE
SINGLE-STOR Y RESIDENCE, A PA R TMENT ,
MOBILE HOME
KEY :
NEW CONSTRUCTION
SMOKE ALARMS WITH SILENCE
FEA TURES RECOMMENDED FOR
ADDITIONAL PROTECTION
KITCHEN
INTERCONNECTED
AC OR AC/DC
SMOKE ALARMS
BEDROOM
BEDROOM HALL
LIVING ROOM
FINISHED BASEMENT
REQUIRED TO
MEET NFP A
RECOMMENDA TIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
BEDROOM
BEDROOM LIVING ROOM
DINING ROOM
MUL TI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APA RTMENT ,
MOBILE HOME
KEY :
NEW CONSTRUCTION
Printed in Mexico M08-0466-156401 K1 01/17
WHA T TO DO IN CASE OF FIRE
• Don’t panic; stay calm. Follow your family escape plan.
• Get out of the house as quickly as possible. Don’t stop to get
dressed or collect anything.
• Feel doors with the back of your hand before opening them.
If a door is cool, open it slowly . Don’ t open a hot door . Keep doors
and windows closed, unless you must escape through them.
• Cover your nose and mouth with a cloth (preferably damp).
T ake short, shallow breaths.
• Meet at your planned meeting place outside your home,
and do a head count to make sure everybody got out safely .
• Call the Fire Department as soon as possible fr om outside.
Give your address, then your name.
• Never go back inside a burning building for any reason.
• Contact your Fire Department for ideas on making your home safer .
Alarmshave various limitations. See“Limitations of SmokeAlarms”
for details.
USING THE SILENCE FEA TURE
The Silence Feature can temporarily quiet an unwanted alarm for up
to 9 minutes. T o use this feature, pr ess the T est/Silence button on the
cover . If the unit will not silence and no heavy smoke is present,
or if it stays in silence mode continuously, it should be replaced
immediately. The LED will flash every 10 seconds while in silence.
The Silence Feature does not disable the unit—it makes it temporarily
less sensitive to smoke. For your safety , if smoke ar ound the unit is
dense enough to suggest a potentially dangerous situation, the unit
will stay in alarm or may re-alarm quickly . If you do not know the
source of the smoke, do not assume it is an unwanted alarm. Not
respondingto analarm can resultin propertyloss, injury ,or death.
TOOLS YOU WILL NEED:
This unit is designed to be mounted
on the ceiling, or on the wall if necessary .
• Pencil
• Drill with 3/16” (5 mm) drill bit
• Standard flathead scr ewdriver
• Hammer
10 YEAR SEALED BA TTERY OPERA TED PHOTOELECTRIC
SMOKE ALARM WITH SILENCE FEA TURE
CONFORMS TO
UL STD 217
Model P1210
REGULAR MAINTENANCE
This unit has been designed to be as maintenance free as possible, but
there ar e a few simple things you must do to keep it working properly .
• T est it at least once a week.
• Clean the Smoke Alarm at least once a month; gently vacuum off
any dust using your household vacuum’ s soft brush attachment,
and test the Smoke Alarm after cleaning. Never use water , cleaners
or solvents since they may damage the unit.
• If the Smoke Alarm becomes contaminated by excessive dirt, dust
and/or grime, and cannot be cleaned to avoid unwanted alarms,
replace the unit immediately .
• Relocate the unit if it sounds frequent unwanted alarms.
See “Locations to Avoid For Smoke Alarms” for details.
• When the battery becomes weak, the Smoke Alarm unit will “chirp”
approximately once a minute (the Low Battery warning). This low
battery warning should last for up to 30 days, but you should
replace the Smoke Alarm immediately to continue your pr otection.
Actual service life depends on the Smoke Alarm and the environment
in which it is installed. Y ou MUST replace the Smoke Alarm immediately
once the unit starts “chirping” (the “low battery warning”).
• NEVERuse an openflame of any kindto test this unit.Y ou might
accidentally damage or set fire to the unit or to your home.
• Ifthe Alarm everfails to test properly , replaceit immediately .
Products under warranty may be r eturned to the manufacturer
forreplacement. See“Limited Warranty”for details.
• DONOT stand closeto the Alarm whenthe hor nis sounding.
Exposure at close range may be harmful to your hearing. When
testing, step away when horn starts sounding.
It is important to test this unit every week to make sure it is working
properly. Using the T est/Silence button is the recommended way to
test this Smoke Alarm. Press and hold the T est/Silence button on the
cover of the unit until the alarm sounds (the unit may continue to alarm
for a few seconds after you release the button). If it does not alarm,
make sure the unit is r eceiving power and test it again. If it still does
not alarm, replace it immediately . During testing you will hear a loud,
repeating horn pattern: 3 beeps, pause, 3 beeps, pause. Red LED
flashes rapidly .
WEEKL Y TESTING
The optional locking feature is designed to pr event unauthorized removal of the alarm. It is not necessary to activate the lock in single-family
households where unauthorized alarm r emoval is not a concern.
T oolsyou will need: Needle-nose pliers orutility knife • Standardflathead screwdriver
The feature uses a locking pin which is molded into the mounting bracket. Remove locking pin by using needle-
nose pliers or a utility knife.
T o permanently remove the locking pin, insert a flathead scr ewdriver between the locking pin and the lock and pry the pin out of the lock.
OPTIONAL LOCKING FEA TURE
SILENCING THE LOW BA TTERY W ARNING
This silence feature can temporarily quiet the Low Battery warning “chirp”.
Press the T est/Silence button on the Alarm. The Red light flashes normally ,
once every 6 minutes, during Low Battery W arning Silence.
After time, the low battery “chirp” will resume. Deactivate the Smoke
Alarm and replace it immediately.
21
4
3
1. Hold the mounting bracket against the ceiling (or wall) so the two
clusters of universal mounting holes
are aligned appr oximately at the
9:00 and 3:00 o’clock positions. See
image. Choose one of the three sets
of holes shown, A, B or C (see image)
and trace around one of the sets. Be
sure to choose a top and bottom slot
on opposite sides so you can rotate
the universal mounting bracket into
position later . This will make it easier
in the future to r emove the mounting
bracket without completely removing
the screws.
WARNING! Do not install this Smoke Alarm over an existing
electrical box. Only AC powered units are intended for
installation over electrical boxes.
2. Put the unit where it won’ t get covered with dust when you drill
the mounting holes.
3. Using a 3/16” (5 mm) drill bit, drill a hole through the center of the
oval outlines you traced.
4. Insert the plastic screw anchors (in the plastic bag with scr ews)
into the holes. T ap the screw anchors gently with a hammer , if
necessary , until they ar e flush with the ceiling or wall.
5. Install the screws but do not tighten completely . Attach the
mounting bracket by aligning the screws in the open portion of
the universal mounting slots and rotating the bracket into place.
Tighten the screws until they ar e snug to secure the bracket.
Do not over tighten.
6. Activating the battery. Mount alarm to mounting bracket to
activate. Once unit is activated, it cannot be turned off.
NOTE: After you activate the battery , the power indicator light may
flash. (If the unit alarms, the light will blink rapidly , and the horn
will repeatedly sound 3 beeps, pause, 3 beeps.)
Once the Smoke
Alarmis on the bracket,you can rotatethe Alarmto adjust the
alignment.
7. T est the Smoke Alarm. See “W eekly T esting.”
8. After 10 years of operation or Low Battery
warning, deactivate the Smoke Alarm: Insert
a tool below edge where shown and br eak
tab. Then slide activation switch to deactivate mode.
NOTE: At end of life or low battery indication (chirp): unit must be
put into deactivation mode to deactivate remaining stor ed energy
in battery . Unit will no longer function once put into this mode.
Unit will resist r e-mounting.
king Pin
TO LOCK THE MOUNTING BRACKET
1. Using needle-nose pliers, detach the pin from
the mounting bracket.
2. Insert the locking pin through the
hole on the back of the smoke alarm as
shown in the diagram.
3. When you attach the alarm to the
mounting bracket the locking pin’ s head
will fit into a notch on the bracket.
TO UNLOCK THE MOUNTING BRACKET
1. Insert a flathead screwdriver
in between the mounting
bracket and the locking pin.
2. Pry the alarm away from the bracket by pushing up the scr ewdriver
and turning the alarm counterclockwise (left) at the same time.