794973
1
Zoom out
Zoom in
Instruction manual
OPTICAL SMOKE ALARM WITH 2 x 1,5V BATTERIES - 5 YEARS LIFETIME
Model: ASD-5
IMPORTANT INFORMATION
Correct usage will ensure you have valuable extra
time to escape. Every correctly installed smoke
detector will increase your potential escape time.
A smoke alarm does not prevent fire.
Install the smoke alarm in the correct place, if
possible in the middle of the ceiling.
Keep the smoke detector out of the reach of
children.
Test the unit on a monthly basis and after any
period of absence. When the alarm does not
sound, have your smoke alarm inspected by the
service point or when the smoke alarm is more
than 10 years old discard the alarm.
CAUTION: Never test with fire!
Clean the smoke alarm regularly (once a month)
using the soft brush of a vacuum cleaner.
In addition the smoke alarm can also be cleaned
using a moist cloth.
If the detector emits a beeping sound every 40
seconds, this means that the batteries are nearly
flat and that you should replace the smoke alarm.
The lifespan of smoke detectors is 10 years.
A false alarm can be silenced by pressing the test
and silence button.
You can make your Model ASD-5 smoke detector
less sensitive for ± 10 minutes by pressing shortly
the test button. The detector will none-
theless sound the alarm if the quantity of smoke
is too significant.
Important instructions in case of a fire alarm:
Plan TWO escape routes and rehearse these with
all members of the family.
Agree upon a meeting point where everyone
gathers in the event of a fire.
In the event of a fire:
Leave the building immediately together with all
the members of your family. Gather outside at the
agreed meeting point.
Make sure everyone is present.
Close all doors behind you and never open a
warm door. If a door is warm, choose an alterna-
tive route.
In the event of considerable build-up of smoke,
crawl out of the building keeping as close to the
floor as possible.
Wherever possible, breathe through a cloth (pre-
ferably moist), or else hold your breath as much
as you can. The majority of deaths and injuries
are caused by smoke inhalation rather than fire
itself.
Call the fire department outside.
Never go back into a burning building.
Additional information can be gathered at the
local fire department.
SPECIFICATIONS
Power: 2 x 1,5V LR03 AAA Alkaline
Recommended
batteries: - PKCELL Ultra alkaline 1.5V
LR03. AAA.AM-4
- HUGE SUPER ALKALINE
1.5V AAA SIZE AM-4 LR03
- DURACELL Plus Power
Alkaline 1.5V LR03 MN2400
NOTE: The correct functioning of the smoke
detector is ensured by the use of one of the
recommended battery.
Battery life: 5 years under normal
conditions
Usage: < 8 μA continue
< 70 mA in alarm
Usage temperature: 0ºC tot + 55ºC
Humidity: < 93% RH at 40ºC
Sensitivity: Conform EN14604
Alarm volume: >85dB at 3 meter
&HUWL¿FDWLRQ $)125(1&(
CPR
POSITIONING THE SMOKE DETECTOR
Recommended locations:
Minimum protection:
A smoke detector on each floor.
Maximum protection:
- Smoke detector in all rooms (with the exception
of bathrooms, kitchen, garages, etc.)
- Heat detectors can be installed in bathrooms,
kitchens, airing cupboards, utility rooms, etc.
within 5 metres of a potential source of fire.
The smoke detector
should preferably
be installed in the
middle of the cei-
ling, at least 50 cm
from the wall.
If ceiling mounting
is not possible to
mount the detector
on the wall. A
minimum of 30 and
maximum of 50 cm
from the ceiling.
(See Figure 3)
In the case of
pitched roofs, install
the smoke detector
on the sloping wall,
at least 90 cm
(measured vertically)
from the ridge of the roof.
See minimum and
maximum protection
(figures 1 & 2)
Ensure that the detector
can always be reached
for testing and cleaning.
Never fit a smoke detector:
In bathrooms, kitchens, shower rooms, garages,
etc. Places where a smoke detector may go off
needlessly due to condensation, normal smoke or
gases. A smoke detector should be fitted at least 5
metres from such sources of smoke.
• Places where the temperature may exceed 55° C
or fall below 0° C, e.g. attics, just above a fire-
place, etc.
In the vicinity of (or adjacent to) decorative objects,
doors, sockets, lights, fittings, windows, wall
ventilators, etc. which could mean that smoke
does not reach the smoke detector. Minimum
50cm away.
Surfaces that are usually warmer or colder than
the rest of the room. Differences in temperature
can prevent smoke from reaching the detector.
Adjacent to or directly above stoves or heaters.
In very high or difficult to reach places. This makes
it hard to reach the detector to test or clean it.
0333-CPR-292126
EN14604:2005/AC 2008
DoP no: 0515
• In very dusty or dirty places. Accumulation of dust
will prevent smoke from reaching the smoke cham-
ber and in time will lead to a false alarm.
Within 1 metre of dimmer switches and wiring.
Some dimmer switches can trigger a fault in the
detector.
Within 1.5 metres of fluorescent lights. Electrical
impulses can adversely affect the functioning of
the detector.
• Outdoors and in spaces where a large number of
insects are found. Small insects in the unit’s detec-
tion chamber can disrupt the functioning of the
detector.
The labels on the rear side of the detector
contain important information.
INSTALLATION
1. Choose a location that satisfies the conditions as
described in: Positioning the smoke detector.
2. Remove the base plate of the detector by turning
the base plate anticlockwise (to the left).
3. Mark the mounting holes
in the base plate and
drill the holes (use a 6 mm
drill). If you do not use
the dowels, then use a 3
mm drill. Screw the base
plate securely onto the
ceiling. Make sure that
the base plate is tight
against the ceiling so
that no air circulation
above the smoke alarm
is possible, which could
impede smoke detection.
If the opening is too large, this must be remedied
by the use of a filler.
4. Insert the supplied batteries in the correct man-
ner into the smoke alarm, pay attention to the +
and -. When activated, the alarm will sound a
tune.
5. Place the smoke detector on the base plate and
turn it until the smoke detector clicks into the
base plate. Turn the smoke detector clockwise
until you hear a click.
6. Make sure that the smoke detector is working
properly and that the battery has been activated
by pressing the test button. A beeping noise that
stops once the test button is released indicates
that the smoke detector has been activated and
is working properly.
ATTENTION: The smoke alarm should be covered
or temporarily removed during renovation work or
structural alterations. Clean the smoke detector
with the soft brush from a vacuum cleaner once the
day’s work is complete, and then replace the
detector, always testing it by pressing the test
button once it has been reinstalled.
WARNING: the smoke alarm loses its functionality
when covered.
FUNCTION TEST
Test your smoke alarm immediately after instal-
lation, monthly and after a period of absence.
press the test button for at least 2-3 seconds
DORXGVLJQDOZLOOVRXQGDQGWKH/('ZLOOÀDVK
every 0,5 sec., this will stop once the test button
has been released.
REPLACING THE BATTERIES
Remove the batteries from the smoke alarm
Place the new batteries in the correct way into
the smoke alarm. Pay attention to
the + and the -.
Place the smoke alarm back on the base plate
and test the smoke alarm, see chapter Function
Test.
FUNCTION AND MEANING OF THE LIGHT
AND SOUND SIGNALS
Normal situation: The red LED light will flash once
every 320 seconds.
Alarm: Whenever the detector detects smoke, it will
emit a loud pulsing alarm and the red LED light will
flash continuously (every 0,5 sec.) until the smoke
has cleared.
Low battery signal: A beeping signal every 40
seconds means that the batteries are nearly flat
and need to be replaced immediately. This signal
will sound for 30 days.
See for the recommended batteries chapter
SPECIFICATIONS
Always do the function test when batteries are
replaced.
Test Button: Check that the smoke detector is
working and that the batteries have been activated
by pressing the test button for at least 2-3 seconds.
The smoke detector will give alarm and stop when
you release the test button. Test the function of the
smoke detector once per month. When the alarm
does not sound, have your smoke alarm inspected
by the service point or when the smoke alarm is
more than 10 years old discard the alarm.
HUSH Button: Your detector is fitted with a pause
button (see figure 5). This is the same button as
the test button. Press the pause/test button shortly.
Your smoke detector will then go into a so-called
reduced sensitivity mode for + 10 minutes. The red
LED light will flash every 10 seconds to indicate
that the Hush button has been activated. The
detector will nonetheless sound the alarm if the
smoke is dense or increasing in quantity.
False Alarm: Press the test- hush button to stop
the alarm. (See Hush button)
Pre-alarm status: The red LED light flashes every
second to indicate that the smoke chamber has
been abruptly contaminated and needs to be
cleaned. If thorough vacuuming does not help, then
the contamination is so serious that the detector
must be returned to the factory.
DUST WARNING: 3 short beep signals every 40
seconds means dust in the smoke chamber.
Remove the batteries and clean the smoke detec-
tor by using the soft brush from a vacuum cleaner.
CAUSES OF FALSE ALARM
The smoke detector can be activated by steam,
condensation, dust, smoke and small insects.
These are to be prevented as far as possible. See
section: Never fit a smoke detector. If a detector is
frequently giving a false alarm, it might be necessa-
ry to install the detector in another location.
Maintenance:
Never allow the detector to come into contact with
fluids.
• Clean the detector regularly (once a month) using
the soft brush from a vacuum cleaner. In addition
the smoke alarm can also be cleaned using a
moist cloth.
• Repairs must be carried out by the manufacturer.
The detector must never come into contact with
liquids.
CAUTION: Do not paint to the detector and do not
cover it.
LIMITATIONS OF SMOKE DETECTORS
In countries where they are commonly in use,
smoke detectors have contributed to reducing
deaths and injuries. Independent bodies have esta-
blished that they were insufficient in around 35% of
fires, namely in the following situations:
Where the batteries have been removed or was
not working. For that reason, you should test the
unit regularly.
Where smoke is not able to reach the detector in
the event of a fire, meaning the unit cannot be set
off. Examples include a fire on another floor
where there is no smoke detector, a fire behind
closed doors, a fire in a chimney or smoke being
blown away from the detector. For that reason,
smoke detectors are recommended in all rooms,
or at any rate on every floor.
Where the alarm is not heard. A person may not
be woken by the alarm if that person had consu-
med excess alcohol and/or drugs.
A few fires are not always detected on time, e.g.
smoking in bed, if there is no smoke detector in
the bedroom. In the case of escaping from gas or
violent explosions, improperly storing explosive
products and flammable liquids (petrol, paint,
methylated spirit, etc.), electrical faults, acids,
children playing with matches (fire).
The lifespan of smoke detectors is 10 years.
PRODUCT WARRANTY
If used and maintained properly, the manufacturer
guarantees this product against material and/or
manufacturing faults for a period of 5 years from
the original date of purchase by the consumer.
Exceptions include damage arising from accidents
or misuse. If the product becomes defective within
the stated period, then it will be repaired or
replaced free of charge. Please do not attempt to
repair the product yourself or tinker with it, which
will invalidate the warranty.
DOP (Declaration of Performance)
The DoP can be downloaded on our website
www.fito.eu
INSTRUCTIONS FOR REMOVAL
Do not dispose of your old detector in
the bin, but rather hand it in to a local
collection point for small, electrical waste.
MADE IN EUROPE
Manufactured in Europe by: ARTON
6 Prutska str. - Chernivtsi 58008 - UKRAINE
European supplier:
Fito Products BV
De Langkamp 12a
3961 MS WIJK BIJ DUURSTEDE
Nederland
info@fito.nl - www.fito.eu
2021-5 vers. 1
16
RETAIN THESE INSTRUCTIONS FOR FUTURE USE!
These instructions for use contain important information for
correct installation and use of your smoke detector. Please
read this information carefully and retain these instructions for
future use.
ACTIVATION OF THE SMOKE ALARM:
Insert the supplied batteries in the correct manner into the
smoke alarm, pay attention to the + and -. When activated, the
alarm will sound a tune.
Make sure that the smoke detector is working and that the batte-
ries have been activated by pressing the test button for a few
seconds. The smoke detector will give alarm and stop when you
release the test button.
&KDUDFWHULVWLFVFHUWL¿HGE\$)125
Ceiling and wall mount YES
Battery powered YES
Autonomy 5 years YES
Individual Alarm Indicator YES
Alarm silence facility YES
Suitable for installation in a
caravan YES
Option to connect external
devices
NO
Interconnectable NO
Certified by : AFNOR Certification
11, rue Francis de Pressensé - F-93571 La Plaine - Saint Denis Cedex
www.afnor.org
kitchen
living room
bathroom
bedroom
hallway
Figure 1
bedroom
bedroom
bedroom
bedroomr bedroomhallway
kitchen hallway living
room
basement
Figure 2
Figure 3
Figure 4
Mounting holes :
screw: 3x25 mm
dowel : 5x30 mm
Figure 5
Test- and
hush button
LED light
0333
EN14604:2005/AC 2008
Essential characteristics: Performance:
Nominal activation conditions/sensitivity, response delay (res-
SRQVHWLPHDQGSHUIRUPDQFHXQGHU¿UHFRQGLWLRQV
Passed
Fito Products BV
De Langkamp 12a
3961 MS Wijk bij Duurstede
The Netherlands
16
0333-CPR-292126
Operational reliability: Passed
Tolerance to supply voltage: Passed
Durability of operational reliability and response delay, tempera-
ture resistance:
Passed
Durability of operational reliability, vibration resistance: Passed
Optical smoke detector,
alerts you in the event
RI¿UHRUVPRNHDQGLV
suitable for residential
buildings.
Durability of operational reliability, humidity resistance: Passed
Durability of operational reliability, corrosion resistance: Passed
Durability of operational reliability, electrical stability: Passed

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Fito ASD-5 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Fito ASD-5

Fito ASD-5 Bedienungsanleitung - Deutsch - 1 seiten

Fito ASD-5 Bedienungsanleitung - Holländisch - 1 seiten

Fito ASD-5 Bedienungsanleitung - Französisch - 1 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info