Before You Start
5
Terms to Know
Use this section to familiarize yourself with these terms that are
unique to this Product.
FieldSense™ Technology/Non-contact voltage (NCV)
Measurement. Voltage measurements by capacitive sensing
technology that completes galvanic isolation. This technology uses
capacitive sensors for measuring AC voltages through non-
galvanic contact, coupled with a Hall Effect jaw that allows
simultaneous current measurements. It enables minimizing
voltage probes connections, therefore reducing hazardous
situations and saving setup-up time, and circuit or machine
downtime. Fluke-developed icon for FieldSense technology is U.
L1-L2-L3. L1, L2, and L3 (or Line 1, Line 2, and Line 3) is a
common naming convention for the wires in three-phase
alternating current (ac) systems. The Clamp features a sequential
line-to-ground measurement that results in a calculated line-to-line
voltage measurement. This voltage measurement is an indication
that the three-phase system is, or is not, working as expected.
Power Factor. Power factor (PF) is the ratio of working power,
measured in kilowatts (kW), to apparent power, measured in
kilovolt amperes (kVA). PF expresses the ratio of true power used
in a circuit to the apparent power delivered to the circuit.
Fluke Connect™App. Fluke Connect is a system that wirelessly
connects your Clamp with an app on your smartphone or tablet.
THD. The total harmonic distortion is a measurement of the
harmonic distortion present in a signal and is defined as the ratio
of the sum of the powers of all harmonic components to the power
of the fundamental frequency.
Fluke Connect™ (377 FC/378 FC)
Fluke Connect™ software (may not be available in all regions)
supports the Clamp to wirelessly connect to a mobile app. The app
shows the measurements and other data on your smartphone or
tablet display. You can share this data with your team and save
collected measurements and calculations to the Fluke Connect
Cloud.
Fluke Connect uses low-power 802.15.4 wireless radio technology
to connect the Clamp with an app on your smartphone or tablet.
The wireless radio does not cause interference with Clamp
measurements.
Radio Frequency Data
Note
Changes or modifications to the wireless 2.4 GHz
radio not expressly approved by Fluke Corporation
could void the user’s authority to operate the
equipment.
For complete information about radio frequency data, go to
www.fluke.com/manuals and search for “Radio Frequency Data
Class A”.
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Fluke declares that the radio equipment contained in this
Product is in compliance with Directive 2014/53/EU. The full text of
the EU declaration is available at the following internet address:
www.fluke.com/declaration-of-conformity
Fluke Connect™ Mobile App
The Fluke Connect™ app works with Apple and Android mobile
products. The app is available for download to your smart device
from the Apple App Store and Google Play.
To use the Fluke Connect app:
1. Open the Fluke Connect app on your device.
2. Turn on the Clamp.
3. Push F to activate the radio on the Clamp. E shows on the
display.
4. On your smartphone, go to Settings > Bluetooth.
5. Verify that Bluetooth is turned on.
6. Go to the Fluke Connect App and in the list of connected
Fluke tools, select 377 FC/378 FC.
You can now take, save, and share measurements with the
app. Go to www.flukeconnect.com for more information about
how to use the app.
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Fluke 377 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Fluke 377

Fluke 377 Bedienungsanleitung - Deutsch - 22 seiten

Fluke 377 Bedienungsanleitung - Holländisch - 22 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info