Operating .................................................................... -10 °C to +50 °C
Storage ........................................................................ -40 °C to +60 °C
Temperature coefficient ................................................ 0.1 X (specified accuracy) / °C (< 18 °C or > 28 °C)
Safety
General ....................................................................... IEC 61010-1: Pollution Degree 2
Measurement .............................................................. IEC 61010-2-033: CAT IV 600 V / CAT III 1000 V
Relative Humidity (Maximum Non-condensing) ......... 90 % to 35 °C
75 % to 40 °C
45 % to 50 °C
Model 77 Series IV
Users Manual
14
Battery Life .................................................................... 400 hrs typical (Alkaline)
Size (H x W x L) ............................................................. 4.3 cm x 9 cm x 18.5 cm
Weight ............................................................................ 420 g
Electromagnetic Compatibility (EMC)
International ................................................................ IEC 61326-1: Portable Electromagnetic Environment, IEC 61326-2-2.
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-
coupled radio frequency energy that is necessary for the internal function of the
equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic
and those directly connected to a low-voltage power supply network that
supplies buildings used for domestic purposes. There may be potential
difficulties in ensuring electromagnetic compatibility in other environments due to
conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the
equipment is connected to a test object.
Korea (KCC) ............................................................... Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is
intended for use in business environments and not to be used in homes.
USA (FCC) .................................................................. 47 CFR 15 subpart B. This product is considered an exempt device per clause
15.103.
Digital Multimeter
General Specifications
15
Function Range Resolution Accuracy ± ( [ % of Reading ] + [ Counts ] )
AC Volts (Average
responding)
6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
2.0 % + 2
(45 Hz to 1 kHz)
DC mV 600.0 mV 0.1 mV 0.3 % + 1
DC Volts 6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.3 % + 1
Continuity 600 Ω 1 ΩMeter beeps at <25 Ω, beeper turns off at >250 Ω;
detects opens or shorts of 250 μs or longer.
Ohms
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
50.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 2
0.5 % + 1
0.5 % + 1
0.5 % + 1
0.5 % + 1
2.0 % + 1
Diode test 2.400 V 0.001 V 1 % + 2
Capacitance
1000 nF
10.00 μF
100.0 μF
9999 μF[1]
1 nF
0.01 μF
0.1 μF
1 μF
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
AC Amps (Average
responding)[2]
60.00 mA
400.0 mA[3]
6.000 A
10.00 A[4]
0.01 mA
0.1 mA
0.001 A
0.01 A
2.5 % + 2
(45 Hz to 1 kHz)
[1] In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
[2] Amps input burden voltage (typical): 400 mA input 2 mV/mA, 10 A input 37 mV/A.
[3] 400.0 mA accuracy specified up to 600 mA overload.
[4] >10 A unspecified.
Model 77 Series IV
Users Manual
16
Function Range Resolution Accuracy ± ( [ % of Reading ] + [ Counts ] )
DC Amps[3]
60.00 mA
400.0 mA[4]
6.000 A
10.00 A[5]
0.01 mA
0.1 mA
0.001 A
0.01 A
1.5 % + 2
Hz [1][ 2]
(ac voltage input) 99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 % + 1
MIN MAX AVG For dc functions, accuracy is the specified accuracy of the measurement function ±12 counts for changes longer than
350 ms in duration.
For ac functions, accuracy is the specified accuracy of the measurement function ±40 counts for changes longer than
350 ms in duration.
[1] Frequency is specified from 2 Hz to 99.99 kHz.
[2] Below 2 Hz, the display shows zero Hz.
[3] Amps input burden voltage (typical): 400 mA input 2 mV/mA, 10 A input 37 mV/A.
[4] 400.0 mA accuracy specified up to 600 mA overload.
[5] >10 A unspecified.
Digital Multimeter
General Specifications
17
Function Overload Protection[1] Input Impedance
(Nominal) Common Mode Rejection Ratio
(1 kΩ Unbalanced) Normal Mode Rejection
Volts AC 1000 V >10 MΩ <100 pF >60 dB @ dc, 50 Hz or 60 Hz
Volts DC 1000 V >10 MΩ <100 pF >120 dB @ dc, 50 Hz or 60 Hz >60 dB @ 50 Hz or 60 Hz
mV 1000 V[2] >10 MΩ <100 pF >120 dB @ dc, 50 Hz or 60 Hz >60 dB @ 50 Hz or 60 Hz
Open Circuit Test
Voltage Full Scale Voltage To:
6.0 MΩ 50 MΩShort Circuit Current
Ohms/Capacitance 1000 V[2]<8.0 V dc <660 mV dc <4.6 V dc <1.1 mA
Continuity/Diode test 1000 V[2]<8.0 V dc 2.4 V dc <1.1 mA
[1] 10
7
V-Hz maximum.
[2] For circuits <0.3 A short circuit. 660 V for high energy circuits.
Function Overload Protection Overload
mA Fused, 440 mA, 1000 V FAST Fuse 600 mA overload for 2 minutes maximum, 10
minutes rest.
A Fused, 11 A, 1000 V FAST Fuse 20 A overload for 30 seconds maximum, 10
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Fluke 77 Series IV wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.