ERROR MESSAGES
The mobile air conditioner is equipped with a 3-minute compressor-delay system which means
the compressor needs 3 minutes to start.
This affects the switching on of the unit (POWER) as well as switching over from one function to
the next, e.g. dehumidify to cooling or heating.
ERROR/
PROBLEM
CAUSE REMEDY
Can I switch the
unit on
immediately after
unpacking it?
No.
The unit must be placed upright for at least 24 hours
after every transport. Otherwise the compressor may be
damaged and there is no capacity.
When switching
on the unit I sense
a smell. What
should I do.
Production-related
cause or incorrect
storage of unit at e.g.
dusty areas.
Odour development can arise on first use and after a
longer period of non-use by storing in unsuitable areas
(e.g. dusty areas).
Run the unit for ½ a day. The smell will disappear after a
while. In the case of intensive odour development, air the
room.
Can I operate the
unit WITHOUT the
extract air hose.
No.
To achieve temperature adjustments, surplus heat or
coldness must be discharged.
At which intervals
should the
activated carbon
filter of the unit
be replaced?
To use the purpose of the filter fully, it should be
replaced every 6 months.
How can I
increase the
efficiency of the
unit?
External circumstances exist which may impact the
efficiency of the unit. Room insulation, use of
wall/window adapter, ratio of window space (solar
radiation), operation of electrical units in the room (EDP),
presence of several persons in the room. You can
increase the efficiency of the unit accordingly by
adjusting such circumstances.
Compressor does
not activate
Depending on ambient temperatures and unit type it may
take approx. 10 minutes after starting the compressor
until the cooling/heating capacity is reached.
unit deactivates. On reaching the set required temperature, the unit
switches off automatically.Check manual setting of the
required temperature as well as the TIMER setting.
How is the m² or
m³ data of the
manufacturer
calculated
The m² or m³ data of the manufacturer for the various
units are average values related to a room height of 2.5
metres. It must be considered that such data can be
clearly underscored or exceeded under certain
circumstances. Circumstances which work against
efficiency of the units include e.g. bad insulation of the
building, large window areas, south facing, attic
apartment, many additional heat sources, such as e.g.
number of persons, EDP, light, kitchen units, washing
units etc.
unit does not
cool correctly
You achieve the most effective and economical cooling
comfort if you already cool the room to be cooled when
the room temperature is not yet heated up. Air
conditioners operate more effectively if the temperature
is to be maintained. To drastically cool the air and
inventory in a fully heated room requires much more time
and energy.
E1 Room temperature
outside the function
range:
Observe all data in these operating instructions
concerning function range.
Heruntergeladen von manualslib.de Handbücher-Suchmachiene
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Fral FSC12 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info