560834
14
Zoom out
Zoom in
Vorherige Seite
1/232
Nächste Seite
14
1. Trigger each security detector by walking into an area protected by a PIR movement detector or by opening a door or
window protected by a door/window contact detector. The control panel chimes. The display shows the ID code of the
zone which the detector is configured to.
2. Remove the battery covers from the PIR movement detectors and the door/window contact detectors to operate the
tamper switches. The control panel chimes. The display shows “Z0X TAMPER”.
3. Activate each button on the remote control (optional accessory) in turn. The control panel chimes. The display shows a
message according to the below table:
Item
Message
R01 DISARM
R01 PART ARM-1
R01 FULLY ARM
R01 PANIC
Note: If a PIR movement detector is at low-battery condition, the control panel will chime and the displays will show “Z0X
BATTERY”.
6.1.2 RF environment test (RF ENVIRONMENT)
If there is radio frequency interference, the displays will show “ENVIRON . . POOR.
6.1.3 Wirefree siren service on/off (WIREFREE SIREN SERVICE ON/OFF)
The solar siren has a service mode facility which prevents the tamper switch from triggering an alarm when it is removed from
the wall. Before removing the siren from the wall, set the siren to “SERVICE MODE ON”. After replacing the batteries and
installing the siren, set the siren to “SERVICE MODE OFF”.
If you select “WIREFREE SIREN SERVICE OFF”, the siren will emit one long beep followed by two short beeps.
If you select “WIREFREE SIREN SERVICE ON”, the siren will emit two short beeps followed by one long beep.
6.1.4 Alarm test (ALARM TEST)
Select “RELAY TEST” to operate the external hard-wired relay contacts (NO/NC).
Select “WIREFREE SIREN TEST” to operate the external solar siren.
Select ‘HARDWIRE SIREN TEST’ to operate the control panel siren and the external hard-wired siren.
6.1.5 Resetting the control panel
The control panel will not return to the default factory settings, but all settings and learned devices will be erased from memory.
1. Press the button.
2. Enter the 4-digit PIN code (Admin).
3. Press the button.
4. Switch off the power supply to the power adaptor.
5. Remove the control panel from the wall bracket.
6. Disconnect the power adaptor from the control panel.
7. Remove the battery cover.
8. Remove and disconnect the backup battery.
9. Set jumper link P1 to the on position.
10. Connect and install the backup battery.
11. Install the battery cover.
12. Connect the power adaptor to the control panel.
13. Switch on the power supply to the power adaptor. The control panel powers up. The display shows “EEPROM RESET”.
After the process is completed, the display shows “DISARM READY”.
14. Set jumper link P1 to the off position.
15. Install the control panel to the wall bracket.
Note: After resetting the control panel, always first learn the devices into the control panel again.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Friedland GlobalGuard Home Alarm System wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Friedland GlobalGuard Home Alarm System

Friedland GlobalGuard Home Alarm System Installationsanweisung - Deutsch, Englisch, Holländisch, Französisch, Italienisch, Portugiesisch, Spanisch - 120 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info