613170
44
Zoom out
Zoom in
Vorherige Seite
1/52
Nächste Seite
OPERATION
42 SA5
After approximately 6 seconds the Siren will
produce a single long beep to indicate that it has
switched into operating mode in a Disarmed state.
Press to return to Standby mode.
SIREN OPERATING MODE
The siren can be switched back into operating mode
using either the Remote Control, Keypad or Control
Panel as follows:
The siren can be switched into service mode using
either the Remote Control or Control Panel as follows:
Remote Control:
Press and hold the button on the remote
control for approximately 6 seconds.
After approximately 6 seconds the Siren will
produce a single long beep to indicate that it has
switched into operating mode in a Disarmed state.
The button should be released during or
immediately after the long beep, otherwise the
system will switch into an Armed state.
Control Panel:
With the system in Standby Mode with the Power
LED ON.
Press
, ,
to enter Test mode, the Arm and Part-Arm LEDs
will flash.
Press to switch the Siren between Service
Mode and normal Operating Mode. LED 5 will
illuminate to show that the appropriate signal is
being transmitted.
After approximately 6 seconds the Siren will
produce a single long beep to indicate that it has
switched into operating mode in a Disarmed state.
Press to return to Standby mode.
BATTERY MONITORING
All system devices continuously monitor their battery
condition. If the battery level of any device drops
below acceptable levels then its low battery indication
will be activated.
In addition if any PIR or Magnetic Contact detector
has
a low battery status it will be recorded by the Control
Panel and a message stored in the
Event Log.
When a low battery indicator is activated the device will
continue to operate normally for up to 2 weeks
(depending upon system use). However, the
battery for
that device should be replaced as soon as possible.
Note: Before removing the battery cover on any device
to replace the battery ensure that the system is put into
Test mode to avoid initiating a Full Alarm condition.
The low battery indication for each system component
is as follows:
Control Panel:
During a period of mains supply interruption the
Control Panel will be powered by the rechargeable
backup batteries.
Under normal battery conditions the Power LED
on the panel will flash at 1s intervals. However,
under low battery conditions the Power LED will
flash at 3s interval.
Remote Control:
When the Remote Control is operated under low-
battery conditions the transmit LED will continue
to flash after the button has been released.
Under normal battery conditions the LED will
extinguish within 2s of the button being released.
PIR Movement Detector:
If the voltage level of any PIR battery falls below
approx. 7.5V, the LED behind the detector lens will
flash when movement is detected to indicate that
the battery needs to be replaced.
Under normal battery conditions the LED does
not illuminate unless the PIR detector is in Walk
Test mode.
Magnetic Contact Detector:
Under low battery conditions, when the Detector is
activated, the transmit LED will be illuminated for
approximately 1s as the door/window is opened.
Under normal battery conditions the LED will not
illuminate as the Detector is operated, (unless the
Detector is in Test Mode with the battery cover
removed).
ESC
ESC
5
? ? ? ?
ENTER
User Access Code
44

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Friedland SA5 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info