Original User Manual FUXTEC FX-DH116_rev03
28
Do not carry out any electrical repairs yourself. Contact a specialist. Do not use a defective
device. When cleaning, make sure that no water gets into the housing. Do not open the
housing to access the internal parts. Do not spray water into the heater.
Do not use solvents, gasoline, toluene, or similar aggressive chemicals to clean the heater.
Ignition electrodes:
Clean, adjust, and, if necessary, replace the ignition electrode. For electrode gaps,
dimensions in MM.
Compressor pressure setting:
The compressor is delivered ex-works and may only be checked and adjusted by qualified
personnel. Interventions in the device can be dangerous.
Remove the cap. If necessary, adjust the pressure to the correct value, turn the screw
clockwise for pressure increase, counterclockwise for the decrease. Air pressure should be
(bar) 0.31.
Electrically:
Check cables, electrical parts, and connections regularly.