761918
39
Zoom out
Zoom in
Vorherige Seite
1/104
Nächste Seite

en Important safety information
When conveying the exhaust air, official and
legal regulations (e.g. state building
regulations) must be followed.
mWarning. Risk of death!
Risk of poisoning from flue gases that are
drawn back in. The exhaust air must not be
conveyed into a functioning smoke or exhaust
gas flue or into a shaft which is used to
ventilate installation rooms that contain heating
appliances. If the exhaust air is to be conveyed
into a non-functioning smoke or exhaust gas
flue, you must obtain the consent of the heating
engineer responsible.
mWarning. Danger of death!
Risk of poisoning from flue gases that are
drawn back in.
Always ensure adequate fresh air in the room if
the appliance is being operated in exhaust air
mode at the same time as room air-dependent
heat-producing appliance is being operated.
Room air-dependent heat-producing
appliances (e.g. gas, oil, wood or coal-operated
heaters, continuous flow heaters or water
heaters) obtain combustion air from the room
in which they are installed and discharge the
exhaust gases into the open air through an
exhaust gas system (e.g. a chimney).
In combination with an activated vapour
extractor hood, room air is extracted from the
kitchen and neighbouring rooms - a partial
vacuum is produced if not enough fresh air is
supplied. Toxic gases from the chimney or the
extraction shaft are sucked back into the living
space.
Adequate incoming air must therefore
always be ensured.
An incoming/exhaust air wall box alone will
not ensure compliance with the limit.
Safe operation is possible only when the partial
vacuum in the place where the heat-producing
appliance is installed does not exceed 4 Pa
(0.04 mbar). This can be achieved when the air
needed for combustion is able to enter through
openings that cannot be sealed, for example in
doors, windows, incoming/exhaust air wall
boxes or by other technical means.
In any case, consult your responsible Master
Chimney Sweep. He is able to assess the
house's entire ventilation setup and will
suggest the suitable ventilation measures to
you.
Unrestricted operation is possible if the vapour
extractor hood is operated exclusively in the
circulating-air mode.
mWarning. Danger of death!
Risk of poisoning from flue gases that are
drawn back in. If installing a ventilation system
in a room with a heat-producing appliance
connected to a chimney/flue, the electricity
supply to the hood must be equipped with a
suitable safety switch.
mWarning. Risk of injury!
Components inside the appliance may have
sharp edges. Wear protective gloves.
Risk of injury!
The appliance may fall down if it has not
been properly fastened in place. All
fastening components must be fixed firmly
and securely.
Risk of injury!
The appliance is heavy. To move the
appliance, 2 people are required. Use only
suitable tools and equipment.
Risk of injury!
Changes to the electrical or mechanical
assembly are dangerous and may lead to
malfunctions. Do not make any changes to
the electrical or mechanical assembly.

General information en
mWarning. Risk of electric shock!
Components inside the appliance may have
sharp edges. These may damage the
connecting cable. Do not kink or pinch the
connecting cable during installation.
Risk of electric shock!
It must always be possible to disconnect
the appliance from the electricity supply.
The appliance must only be connected to a
protective contact socket that has been
correctly installed.
The mains plug of the mains power cable
must be easily accessible after installation
of the appliance. If this is not possible, an
all-pole isolating switch must be integrated
into the permanent electrical installation
according to the conditions of overvoltage
category III and according to the
installation regulations.
The permanent electrical installation must
only be wired by a professional electrician.
We recommend installing a residual-current
circuit breaker (RCCB) in the appliance's
power supply circuit.
mWarning. Risk of electric shock!
Incorrect repairs are dangerous. Repairs may
only be carried out and damaged power cables
replaced by one of our trained after-sales
technicians. If the appliance is defective,
unplug the appliance from the mains or switch
off the circuit breaker in the fuse box. Contact
the after-sales service.
mWarning. Danger of suffocation!
Packaging material is dangerous to children.
Never allow children to play with packaging
material.
K
General information
General inf ormation.
Exhaust air mode
mWarning. Risk of death!
Risk of poisoning from flue gases that are drawn back in. The
exhaust air must not be conveyed into a functioning smoke or
exhaust gas flue or into a shaft which is used to ventilate
installation rooms that contain heating appliances. If the
exhaust air is to be conveyed into a non-functioning smoke or
exhaust gas flue, you must obtain the consent of the heating
engineer responsible.
If the exhaust air is conveyed through the outer wall, a
telescopic wall box should be used.
Exhaust duct
Note: . The device manufacturer does not assume any warranty
for complaints attributable to the pipe section.
The device achieves its optimum performance by means
of a short, straight exhaust air pipe and as large a pipe
diameter as possible.
As a result of long rough exhaust air pipes, many pipe
bends or pipe diameters that are smaller than 150 mm,
the optimum extraction performance is not achieved and
fan noise is increased.
The pipes or hoses for laying the exhaust air line must
consist of non-combustible material.
Round pipes
An inner diameter of 150 mm, but at least 120 mm, is
recommended.
Flat ducts
The inner cross-section must correspond to the diameter of the
round pipes.
dia. 150 mm ca. 177 cm2
dia. 120 mm ca. 113 cm2
Flat ducts should not have any sharp deflections.
Use sealing strips for deviating pipe diameters.
Checking the wall
The wall must be level, vertical and adequately load-
bearing.
The depth of the bore holes must be the same length as
the screws. The wall plugs must have a secure grip.
The enclosed screws and wall plugs are suitable for solid
brickwork. Suitable fasteners must be used for other
structures (e.g. plasterboard, porous concrete, poroton
bricks).
7KHPD[ZHLJKWRIWKHH[WUDFWRUKRRGLV NJ
Electrical connection
mWarning. Risk of electric shock!
Components inside the appliance may have sharp edges.
These may damage the connecting cable. Do not kink or pinch
the connecting cable during installation.
The required connection data can be found on the rating plate
inside the appliance; to do this, remove the metal mesh grease
filter.
Length of the cable: approx. 1.30 m
This appliance complies with the EC interference suppression
regulations.
39

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gaggenau AW240191 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info