41
11.3 Installation
The steam oven must be installed at a height of at
least 900 mm or more above floor level.
When installing it over an oven, install the steam
oven first. Then install the oven.
Proceed as follows:
– When unpacking the appliance, check it for
transport damage. Damaged appliances must not
be operated.
– Insert the appliance in the item of furnishing.
Note: use a spirit level to check that the steam
oven is installed exactly horizontally.
– Use the included wood screw to firmly bolt it to
the face timber surface of the conversion cabinet
on the handle and hinge side, directly underneath
the top panel.
– Guide the water supply and drain hoses
downward to the connection units.
– Establish the electrical and installation
connections in accordance with the instructions
(see page 40).
– Check that the appliance functions properly.
– Clean it (see chapter on cleaning and care).
Fig. 37
place electrical
junction box here
minimum distance of 10 cm
between wall and appliance
do not place electrical
junction box directly behind
appliance (1x16A ou 2x10A)
max. length 5 m