15
Technical data (gas)
Burners: Full burning 5 kW
Low burning 0.3 kW
Gas connection: R 1/2’’ union nut for R 1/2’’
bracket to DIN 1999, conical-cylindrical
Technical data (electrical)
Rated consumption 15 W
Voltage 220-240 V
Frequency 50-60 Hz
Technical modifications reserved.
11. Technical Data / Nozzle Table
Countries AT BE CH CZ DE BE CH CZ DK AT CH DE
DE DK ES FI ES FI FR GB
FR GB GR HU GR HU IE IS
IE IS IT LU NL IT LU NO PL
PL PT RU SE PT RU
Gas family Natural gas Natural gas LPG/Propane LPG/Prop.
Gas type H / E / L (G 20/25) LL (G 25) 3 + (G30/31) (G30/31)
Pressure 20/25 mbar 20 mbar 28-30/37 mbar 50 mbar
Nozzle, full burn, outer 1,55 1,70 B 1,00 0,87
Nozzle, low burn, outer 0,73 0,81 0,51 0,45
Nozzle, full burn, inner 0,58 0,63 0,37 0,33
Nozzle, low burn, inner 0,45 0,51 0,31 0,25
Air gap adjustm. outer [mm] 0000
Air gap adjustm. inner [mm] * * * *
Total output 5 kW 5 kW 5 kW 5 kW
Total consumption 0,50 m
3
/h 0,55 m
3
/h 360 g/h 360 g/h
* open, fixed
Nozzle table wok burner