12
EN
7. Troubleshooting
DANGER ! Electric shock!
Electric shock if water leaks into the drill!
V Unplug the drill before you start troubleshooting.
Fault Possible Cause Remedy
The pump does not The suction hose is v Check the suction
start to drain water not airtight or is stuck. hose and seal if
within 12 seconds necessary.
No liquid to be drained v Ensure that there is
on the suction side. sufficient liquid to be
drained on the suction
side.
Pumping stops during The suction hose is v Immerse the suction
operation stuck. hose freely into the
liquid to be pumped.
No liquid to be drained v Ensure that there is
on the suction side. sufficient liquid to be
drained on the suction
side.
In the event of other faults please contact GARDENA Service.
Repairs should only be carried out by GARDENA service centres
or dealers authorised by GARDENA.
8. Technical Data
Art. no. 1490
Required rated power of drill
in temporary operation / min. 450 W /
over 30 min. min. 600 W
Drive shaft 8 mm
Max. performance with 13 mm (½
"
) hose 1.7 m³/h
with 19 mm (¾
"
) hose 2.4 m³/h
Pressure approx. 3 bar
Max. pumping height approx. 30 m