6.3 Information messages
The information messages in the table below are shown in the display of the product. Speak to your GARDENA
representative if the same message shows frequently.
Message Cause Action
Low battery
The product cannot find the charging station. Change the position of the guide wire. Refer
to
To install the guide wire on page 20
.
The battery is at the end of its life cycle. Replace the battery. Refer to
Battery on
page 36
.
The antenna of the charging station is defec-
tive.
Do a check if the indicator lamp in the charg-
ing station flashes red. Refer to
Indicator
lamp in the charging station on page 44
.
The charging plates on the product or con-
tact plates on the charging station are defec-
tive because of corrosion.
Clean the charging and contact plates using
a fine grade emery cloth. If the problem stays
speak to your approved servicing dealer.
Settings restored
A
Reset all user settings
has been done. Usual operation of the product.
Guide not found
The guide wire is not connected to the charg-
ing station.
Connect the guide wire to the charging sta-
tion. Refer to
To install the guide wire on
page 20
.
Damage in the guide wire. Replace the damaged section with new
guide wire.
The guide wire is not connected to the boun-
dary loop.
Connect the guide wire correctly to the boun-
dary loop. Refer to
To install the guide wire
on page 20
.
Guide calibration
failed
The product has not calibrated the guide wire
because of an error.
Install the guide wire correctly. Refer to
To
install the guide wire on page 20
.
Guide calibration
done
The product has calibrated the guide wire. Usual operation of the product.
Connection changed
New loop signal changed. Usual operation of the product.
1298 - 015 - 20.08.2021 Troubleshooting - 43