Rev. 4 Page G-5
BULKHEAD
WEATHER RADAR R/T MUST BE
ELECTRICALLY BONDED TO BULKHEAD
1.
2.
MS20659-131 TERMINAL LUG (OR EQUIVALENT).
ENSURE THAT CHAFE PROTECTION IS INSTALLED
WHERE THE HSDB WIRES ENTER THE BULKHEAD.
OVERBRAID
1 2
INSTALL 5/16" GROUNDING HARDWARE IN
ACCORDANCE WITH AC 43.13-1B, SECTION 11-189. IF
THERE IS AN EXISTING HOLE LOCATED IN AN
APPROPRIATE AREA IT MAY BE UTILIZED FOR THE
GROUNDING HARDWARE – OTHERWISE AN EXISTING
FASTER (5/16" OR LARGER) MAY BE USED. IF THERE IS
NO EXISTING HOLE OR SUITABLE FASTER USABLE FOR
THIS PURPOSE THEN DRILL AND DE-BURR A 0.323"-
0.332" HOLE.
2" MAXIMUM
EXPOSED CABLE