SITE REQUIREMENTS
FLUE & CHIMNEY REQUIREMENTS
The chimney or flue system must comply with the rules in force,
and must be a minimum of 127mm (5") in diameter.
The minimum flue height for the appliance must be 3 metres (10ft).
Any horizontal flue run from the rear outlet must not exceed
100mm from the back of the appliance.
A minimum of 100mm vertical flue above the top outlet spigot
should be provided before any offset of the flue.
The chimney or flue must be free from any obstruction. Any
damper plates must be removed or secured in the fully open
position, and no restrictor plates fitted.
The chimney must be swept prior to the installation, but it need not
be swept if it can be seen the chimney is clean and unobstructed
throughout its entire length.
A 5" (127mm) liner must be used if fitting the appliance into an
existing brick built chimney.
Larger lined flues can work, but in some instances could cause
cold start flue problems resulting in nuisance shutdown. Lined flues
above 7" (175mm) are not recommended.
The European chimney standards now describe chimneys and
flues by their temperature, pressure and resistance to corrosion,
condensation and fire. To identify the correct flue system, the
minimum flue specification is shown in the Technical Specification.
Existing chimneys are not covered by this system.
FLUE OPTIONS
A range of Vitreous Enamel Gloss Black flue pipe is available
to compliment the Huntingdon. Please contact your Gazco
retailer for further information.
GAS SUPPLY
THIS APPLIANCE IS INTENDED FOR USE ON A GAS
INSTALLATION WITH A GOVERNED METER.
Before installation, ensure that the local distribution conditions
(identification of the type of gas and pressure) and the adjustment
of the appliance are compatible.
Ensure the gas supply delivers the required amount of gas and is
in accordance with the rules in force.
You can use soft copper tubing on the installation and soft soldered
joints outside the appliance and below the fire.
A means of isolating the gas supply to the appliance must be
provided independent of any appliance control.
All supply gas pipes must be purged of any debris that may have
entered prior to connection to the appliance.
The gas supply must be installed in a way that does not restrict the
removal of the appliance for servicing and inspection.
VENTILATION
IMPORTANT: Ensure any national ventilation requirements are
taken into account during installation of the appliance.
UK ONLY:
The Huntingdon 30 has a nominal input not exceeding 7.0kW and
does not normally require any additional permanent ventilation.
FOR THE REPUBLIC OF IRELAND REFER TO THE RULES IN
FORCE FOR VENTILATION REQUIREMENTS.
CO ALARMS
Building regulations require that whenever a new or replacement
fixed gas burning appliance is installed in a dwelling, a carbon
monoxide alarm complying with BS EN 50291-1(latest edition)
must be fitted in the same room as the appliance. Further guidance
and recommendations on the installation of carbon monoxide
alarms is available in BS EN 50292 (latest edition) and from
manufacturers’ instructions.
Provision of an alarm must not be considered a substitute for
either installing the appliance correctly or ensuring regular
servicing and maintenance of the appliance.
APPLIANCE LOCATION
Building Regulations state this appliance must stand on a non-
combustible hearth that is at least 12mm thick and projects 50mm
minimum from the base of the appliance in all directions, however
Gazco recommend the hearth extends to the following dimensions.
C
A
B
DIMENSION A B C
Huntingdon 20 716 420 12
Huntingdon 30 853 451 12
Huntingdon 40 941 482 12
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gazco Huntingdon 20-30-40 - Conventional Flue wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info