INSTALLATIONS INSTRUCTIONS
SITE REQUIREMENTS
SAFETY PRECAUTIONS
This appliance must be installed according to local and national
codes of practice. Failure to install the appliance correctly could
lead to prosecution. Read these instructions before installing
and using this appliance.
These instructions must be left intact with the user.
Do not attempt to burn rubbish on this appliance.
Keep all plastic bags away from young children.
Do not place any object on or near to the appliance and allow
adequate clearance above the appliance.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN USE,
WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT THE
APPLIANCE.
IMPORTANT: REFER TO DATA BADGE AND
TECHNICAL SPECIFICATION AT THE FRONT OF
THE MANUAL TO ENSURE THE APPLIANCE IS
CORRECTLY ADJUSTED FOR THE GAS TYPE AND
CATEGORY APPLICABLE IN THE COUNTRY OF
USE.
FOR DETAILS OF CHANGING BETWEEN GAS TYPES
REFER TO SERVICING INSTRUCTIONS.
FLUE & CHIMNEY REQUIREMENTS
WHEN INSTALLING A FLUE SYSTEM PLEASE REFER TO THE
MANUFACTURERS INSTRUCTIONS.
The European chimney standards now describe chimneys and
flues by their temperature, pressure and resistance to corrosion,
condensation and fire. To identify the correct flue system, the
minimum flue specification is shown in the Technical Specification.
Existing chimneys are not covered by this system.
The chimney or flue system must comply with the rules in force,
and must be a minimum of 127mm (5") in diameter.
A 5" (127mm) liner must be used if fitting the appliance into an
existing brick built chimney.
Larger lined flues can work, but in some instances could cause
cold start flue problems resulting in nuisance shutdown. Lined flues
above 7" (175mm) are not recommended.
Suitable systems are:
a) Flexible liner which must be continuous from the
appliance spigot to the roof terminal.
b) Gazco Linerless kit.
UNDER NO CIRCUMSTANCES MUST THE LINERLESS KIT BE
USED WITH ANY INSTALLATION OTHER THAN AN EXISTING
MASONRY CHIMNEY WHICH HAS A MINIMUM DIAMETER OF
178mm (7”). THE CHIMNEY MUST BE SOUND AND CLEAN. IF
PREVIOUSLY USED FOR SOLID FUEL, IT MUST BE SWEPT
PRIOR TO PROCEEDING WITH THE INSTALLATION.
NOTE: If the Linerless kit is to be used, due care should be taken
to prevent condensation forming in the chimney. Do not fit the
Linerless Kit if the chimney is taller than 10 metres (external wall)
or 12 metres (internal wall).
The minimum flue height for the appliance must be 3 metres (10ft).
Any horizontal flue run from the rear outlet must not exceed 100mm
from the back of the appliance.
The chimney or flue must be free from any obstruction. Any damper
plates must be removed or secured in the fully open position, and
no restrictor plates fitted.
The chimney must be swept prior to the installation, but it need not
be swept if it can be seen the chimney is clean and unobstructed
throughout its entire length.
Steel Register
Plate with Clamp
that holds the Flex
Adapter
Flex Pipe Adapter
connects to stove
ue pipe
Stove Flue Pipe
running from the
stove to the Flex
Pipe Adapter
Stove
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gazco Loft Conventional Flue wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info