813418
24
Zoom out
Zoom in
Vorherige Seite
1/36
Nächste Seite
24
IGNITION FUNCTIONAL CHECK 1
PILOT WILL NOT LIGHT
Ensure there is no debris around the pilot assembly,
(e.g. soot, etc.) which could short the spark, clean the area.
Operate the valve.
Is there a spark?
Consult User
Instructions and retry.
Check alignment of pilot
burner head, change the
ignition lead.
See Replacing Parts, section 2.
Check isolation tap and
gas meter, retry.
Correct and
retry.
Purge the gas pipes and retry.
GO TO THE NEXT
CHART IGNITION
FUNCTIONAL CHECK 2
SYSTEM OK
There is a blockage in the system, check the inlet test point,
the mag seating and valve. Check thermocouple leads for correct orientation,
condition and connection
Is the gas turned on to the
appliance?
Is the gas pressure correct?
Has the system got
any air in it?
Does the pilot light?
Is the control being
operated correctly?
Will the pilot light
with a match?
No Yes
No
Yes
No
Yes
Yes
No
No
Yes
No
No
Yes
Yes
SERVICING INSTRUCTIONS
SERVICING/FAULTFINDINGCHARTS
1. SERVICING REQUIREMENTS
IMPORTANT – The glass panel on this appliance should be
checked for any signs of damage on the front face of the glass
panel (scratches, scores, cracks or other surface defects). If
damage is observed, the glass panel must be replaced and the
appliance must not be used until a replacement is installed.
Under no circumstances should the appliance be used if any
damage is observed. Please isolate the appliance until a
replacement glass panel has been obtained and installed.
Replacement glass panels can be purchased from Gazco via the
dealer from which the appliance was purchased or any other
Gazco distributor.
This appliance must be serviced at least once a year by a
competent person.
All tests must be carried out in accordance with the current Gas
Safe recommendations.
1.1 Before any tests are undertaken on the appliance:
Conduct a gas soundness test for the property to ensure
there are no gas leaks prior to starting work.
1.2 Fully check the operation of the appliance.
Special checks
1.2.1 Clean any lint or fluff from the pilot - pay particular
attention to the aeration holes of the pilot.
1.2.2 Clean away any fluff or lint from under the burner.
1.2.3 Check the spark gap on the pilot is correct.
Correct any faults found during the initial tests.
Recommission the appliance conducting the usual safety
checks.
1.3 Advise the customer of any remedial action taken.
REPLACE BATTERIES BEFORE ATTEMPTING TO RECTIFY ANY
FAULTS.
IF THE FIRE DOES NOT WORK, BUT HAS WORKED IN THE
PAST:
CHECK THE EMERGENCY SHUT OFF SWITCH
IN THE BOTTOM RIGHT CORNER BY THE DOOR IS
SWITCHED ON, SEE USER SECTION, PAGE 6
Symptom Cause Remedy
3 Short beeps from
control Batteries low in
appliance Replace appliance
batteries
No ignition, 5 second
continuous tone (there
may be several short
beeps before)
1. On/Off switch is in
OFF position
2. Loose/damaged
wire
1. Move switch to
ON position
2 Check interrupter
block and wires
No ignition, no tone,
motor turns slightly when
operated
Receiver board
damaged Replace receiver
No pilot flame and
control continues to
spark
Thermocouple circuit
wired incorrectly Correct wiring
Pilot lights, control
continues to spark, value
shuts down after 10 - 30
seconds
1. No spark at pilot
burner
2. Loose/damaged
wire
1. Rectify spark at
pilot burner
2. Check interrupter
and wires
Electronic Control Valve Fault Analysis
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gazco RIVA VISION LARGE 8000 series Balanced Flue wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.