IGNITION FUNCTIONAL CHECK 1
PILOT WILL NOT LIGHT
Ensure there is no debris around the pilot assembly,
(e.g. soot, etc.) which could short the spark, clean the area.
Operate the valve.
Is there a spark?
Consult User
Instructions and retry.
Check alignment of pilot
burner head, change the
ignition lead.
See Replacing Parts, section 2.
Check isolation tap and
gas meter, retry.
Correct and
retry.
Purge the gas pipes and retry.
GO TO THE NEXT
CHART IGNITION
FUNCTIONAL CHECK 2
SYSTEM OK
There is a blockage in the system, check the inlet test point,
the mag seating and valve. Check thermocouple leads for correct orientation,
condition and connection
Is the gas turned on to the
appliance?
Is the gas pressure correct?
Has the system got
any air in it?
Does the pilot light?
Is the control being
operated correctly?
Will the pilot light
with a match?
No Yes
No
Yes
No
Yes
Yes
No
No
Yes
No
No
Yes
Yes
SERVICING INSTRUCTIONS
SERVICING/FAULTFINDINGCHARTS
1. SERVICING REQUIREMENTS
IMPORTANT – The glass panel on this appliance should be
checked for any signs of damage on the front face of the glass
panel (scratches, scores, cracks or other surface defects). If
damage is observed, the glass panel must be replaced and the
appliance must not be used until a replacement is installed.
Under no circumstances should the appliance be used if any
damage is observed. Please isolate the appliance until a
replacement glass panel has been obtained and installed.
Replacement glass panels can be purchased from Gazco via the
dealer from which the appliance was purchased or any other
Gazco distributor.
This appliance must be serviced at least once a year by a
competent person.
All tests must be serviced by best practice as described by the
current Gas Safe recommendations.
1.1 Before any tests are undertaken on the stove:
• Conductagassoundnesstestforthepropertytoensure
there are no gas leaks prior to starting work.
1.2 • Fullychecktheoperationofthestove
Special checks
1.2.1 Clean any lint or fluff from the pilot - pay particular
attention to the aeration hole in the side of the pilot
1.2.2 Clean away any fluff or lint from under the burner
1.2.3 Check the spark gap on the pilot is correct
•Correctanyfaultsfoundduringtheinitialtests
•Re-commissionthestoveconductingtheusualsafety
checks
1.3 Advise the customer of any remedial action taken.
REPLACE BATTERIES BEFORE ATTEMPTING TO RECTIFY ANY
FAULTS
IF THE FIRE DOES NOT WORK, BUT HAS WORKED IN THE
PAST:
•CHECKTHEEMERGENCYSHUTOFFSWITCH,
(BOTTOM RIGHT CORNER BY THE DOOR), IS
SWITCHED ON, SEE USER SECTION, PAGE 6
ELECTRONIC CONTROL VALVE FAULT ANALYSIS
Symptom Cause Remedy
3 short beeps from
control
Batteries low in ap-
pliance
Replace appliance
batteries
No ignition, 5 seconds
continuous tone (there
can be several short
beeps before)
1. ON/OFF switch
is in OFF position
2. Loose/damaged
wire
1. Move switch to
ON position
2 Check interrupter
block and wires
No ignition, no tone, mo-
tor turned slighted when
operated
Receiver board
damaged
Replace receiver
No pilot ame and control
continues to spark
Thermocouple
circuit wired incor-
rectly
Correct wiring
Pilot lights, control contin-
ues to spark, vale shuts
down after 10-30 seconds
1. No spark at pilot
burner
2. Loose/damaged
wire
1. Rectify spark at
pilot burner
2. Check interrupter
and wires
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gazco Riva VISION LARGE 8000 series Conventional Flue wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info