813423
5
Zoom out
Zoom in
Vorherige Seite
1/36
Nächste Seite
5
User Instructions
2.2 There are 3 different modes available for controlling and
operating the appliance:
1. Manual Mode
2. Temp Mode (Automatic)
3. Timer Mode (Automatic)
2.3 In MANUAL MODE you can:
turn on the main burner using the UP button
regulate the flame from high to low and back
turn off the burner leaving just the pilot burning
In TEMP MODE (Automatic) you can:
set the room temperature so the thermostat in the remote
automatically maintains that temperature
In TIMER MODE (Automatic) the fire:
turns on and off according to the set time periods
automatically regulates the room temperature during the
set periods
NOTE: When operating the fire in Temp or Timer mode,
the pilot remains lit and the fire then automatically
switches on at programmed times to bring the room to
the set temperature whether or not you are in the room.
NEVER LEAVE ANY COMBUSTIBLE MATERIALS
WITHIN 1 METRE OF THE FRONT OF THE APPLIANCE.
Switching Between Modes
2.4 Press the SET button to change to Temperature Mode.
Press again to change to Timer Mode.
Keep pressing to run through all operating modes. These
are:
— MAN
— DAY TEMP
— NIGHT TEMP
— TIMER
and back to MAN
NOTE: MAN mode can also be reached by pressing
either the UP or DOWN button.
Manual Mode
2.5 Press the OFF button and the UP button simultaneously.
You hear several clicks and audible beeps as the fire begins
the ignition process, (up to 30 seconds).
Turning the appliance Off:
Press the OFF button to turn the appliance off
FOR SAFETY, YOU MUST WAIT 30 SECONDS BEFORE
LIGHTING THE FIRE AGAIN.
Increasing the Flame Height:
Press the UP button once to increase flame height one stage.
Press and hold the UP button to increase to maximum.
Decreasing the Flame Height:
Press the DOWN button once to decrease flame height
one stage. Press and hold the DOWN button to decrease to
minimum. At the lowest point the fire goes to 'Standby Mode'
(Only Pilot lit).
NOTE: While pressing a button a symbol indicating
transmission appears on the display. The receiver
confirms transmission with a sound signal.
Temp Mode (Automatic)
2.6 The display shows the current room temperature.
To increase or decrease the fire’s output:
Press the SET button to select either the DAY TEMP or the
NIGHT TEMP mode by briefly pressing the SET button.
Hold the SET button until the TEMP display flashes and
then let go.
Set the desired temperature with the UP and DOWN arrows.
(Minimum temperature 5C, maximum 40C or 40F to 99F
when Fahrenheit is the preferred option)
Press the OFF button to stop the display flashing or wait
to return to TEMP mode.
NOTE: If you set a temperature that is beneath the
current room temperature, the fire automatically
switches to PILOT (Stand by).
If you would like the Night temperature control to turn
off then decrease the temperature until [--] is displayed.
Timer Mode (Automatic)
2.7 There are two programmable settings you can make over a
24 hour period, P1 and P2. These are normally used to
provide an early morning and evening setting for each
working week:
P1 + = Start Timed Setting 1
P1 + = End of Timed Setting 1
P2 + = Start Timed Setting 2
P2 + = End of Timed Setting 2
2.8 P1 - Program 1 for a Timed Setting
Press the SET button until the TIMER mode is displayed.
Hold the SET button. The displays flashes the current time
for P1. While the time displayed is flashing you can alter
the hours and minutes set.
To set the time your fire first lights, change P1
— Press the UP button to alter the hour.
— Press the DOWN button to alter the minutes
in 10 minute increments.
Press SET again to move to the end setting for P1 This is
the time your Studio first shuts down:
— Press the UP button to alter the hour.
— Press the DOWN button to alter the minutes.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gazco riva Vision Large Conventional Flue wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info