1. Flue & Chimney Requirements
1.1 The chimney or flue system must comply with the rules in
force, and must be a minimum of 127mm in diameter. (5").
1.2 The minimum flue height for the appliance must be 3 metres
(10ft). Any horizontal flue run from the rear outlet must not
exceed 100mm from the back of the appliance.
1.3 The chimney or flue must be free from any obstruction. Any
damper plates must be removed or secured in the fully open
position, and no restrictor plates fitted.
1.4 The chimney must be swept prior to the installation, but it
need not be swept if it can be seen the chimney is clean and
unobstructed throughout its entire length.
NOTE: If it is intended to fit the stove into an existing
brick- built chimney a 5" (127mm) liner must be used.
Larger lined flues may work, but in some instances
could cause cold start flue problems resulting in
nuisance shutdown. Lined flues above 7" (175mm) are
not recommended.
The European chimney standards now describe chimneys
and flues by their temperature, pressure and resistance to
corrosion, condensation and fire. To identify the correct flue
system, the minimum flue specification is shown in the
Technical Specification. Existing chimneys are not covered
by this system.
2. Gas Supply
THIS APPLIANCE IS INTENDED FOR USE ON A GAS
INSTALLATION WITH A GOVERNED METER.
2.1 Before installation, ensure that the local distribution
conditions (identification of the type of gas and pressure)
and the adjustment of the appliance are compatible.
2.2 Ensure the gas supply delivers the required amount of gas
and is in accordance with the rules in force.
2.3 Soft copper tubing and soft soldered joints can be used but
must not be closer than 50mm to the base of the tray.
2.4 A means of isolating the gas supply to the appliance must
be provided independent of any appliance control.
2.5 All supply gas pipes must be purged of any debris that may
have entered prior to connection to the appliance.
2.6 The gas supply must be installed in a way that does not
restrict the removal of the appliance for servicing and
inspection.
Installation Instructions
Site Requirements
3. Ventilation
IMPORTANT: Ensure any national ventilation
requirements are taken into account during installation
of the appliance.
3.1 This appliance has a nominal input not exceeding 7.0kw and
therefore, does not normally require any additional
permanent ventilation.
3.2 If however, spillage is detected when commissioning the
appliance, there may be insufficient natural ventilation and
additional ventilation may be required.
FOR THE REPUBLIC OF IRELAND REFER TO THE
RULES IN FORCE FOR VENTILATION REQUIREMENTS.
4. Appliance Location
4.1 Building Regulations state this appliance must stand on a
non-combustible hearth that is at least 12mm thick and
projects 50mm minimum from the base of the appliance in
all directions, however Gazco recommend the hearth
extends to the following dimensions, see Diagram 1.
C
A
B
1
A = 1009mm
B = 525mm
C = 12mm
4.2 Do not install in a room that contains a bath or shower.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gazco Steel Manhattan Log Conventional wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info