Instructions for Assembly and Use
TCS-Cody 1/1
Electronic encoder-type lock for garage door drives
The TCS-Cody is a modern and safe alternative to traditional key switches. The
TCS-Cody can safely be used after two simple programming steps (master code
and pass code). For opening or closing of the door only a four- or five-digit nume-
ral code (pass code) has to be entered, which has been previously programmed via
the master code by an authorized person.
After correct input of the pass code and pushing the key button the drive is trigge-
red by the potential-free relay contact.
The high flexibility of the encoder is achieved by extensive programmability of the
individual operating functions. All sections required for operation are, however, pre-
programmed and thus immediately ready for use.
Technical Data:
24 V series 230 V series
Supply voltage 12 - 24 V AC / DC 230 V AC 50 Hz
Output 1x NO,NC relay contact, 1x NO,NC relay contact,
isolated, 8 A 250 V isolated, 8 A 250 V
Connections 2.5 mm
2
max., 2.5 mm
2
max.,
Ambient- -20 ˚C to +60 ˚C -20 ˚C to +60 ˚C
temperature
Adaptation of the TCS-Cody 1/1 to special requirements:
The TCS-Cody 1/1 is provided with a series of flexible time settings which allow the adapta-
tion to special cases of application. For programming these special operating modes please
ask for our flow chart for the TCS-Cody series, if required!
geba GmbH is released of its obligations regarding guarantee and product liability if - without
prior permission - the unit has been modified, or if the installation is unproper or not in accordan-
ce with our instruction manual.
The installer has to take care that the EMC-regulations are respected.
GB
The most important characteristics of the TCS-Cody are:
➢ Simple operation, programming and assembly.
➢ Water-protected enclosure.
➢ A maximum of safety:
➢ The electronic decoder is separately installed in the
protected area
➢ Up to 50 different pass codes can be stored
Up to 100 million different coding possibilities
Variable lock-out function
Nearly unlimited data security, even with power failure
➢ Special TIPTOMATIC-function for garage doors: After input of the pass
code the door can be stopped within the TIPTOMATIC time adjusted by
actuation of any key, and be closed or opened by repeated actuation
of any key.
➢ One potential-free relay output
➢ High switching capacity for direct control of appliances