SUGGESTION:
The recommended filtration timeframe is 24 hours. The
minimal filtration timeframe is 6 hours.
After selecting the spa filtration parameters for the CHEMI-
CAL TREATMENT device adjust the parameters of the water
as well. The spa filtration and water parameters determine
what settings the CHEMICAL TREATMENT device will use for
correct monitoring and regulation of the spa.
If you change the mass of the water of the filtration time-
frame of the spa, you must update the parameters.
- Depth
- Length
- Width
USER GUIDE FOR THE CHEMICAL TREATMENT
DEVICE
Setting the parameters of the water
The parameters of the water settings define the attributes
of the spa water for the CHEMICAL TREATMENT device. The
CHEMICAL TREATMENT device also contains presets based on
the following conditions:
- Indoor or outdoor spa.
- The level of water hardness.
- The average water temperature.
Because each of these parameters affect the operation of the
CHEMICAL TREATMENT device, appropriate parameters of
the water must be defined to ensure optimal performance
of the CHEMICAL TREATMENT device in your spa. Set water
parameters when installing CHEMICAL TREATMENT DEVICE.
1. In the main menu select SETTINGS, then PARAMETERS,
then select the spa PARAMETERS menu item to enter the
next screen.
2. SPA Select your spa type using the checkboxes.
- INDOOR
- OUTDOOR
- EXTREME CONDITIONS
3. AVERAGE TEMPERATURE
Select the average temperature of the spa.
WARNING! This parameter affects the maximum hours dura-
tion of the disinfection process.
4. WATER HARDNESS:
Enter the water hardness level of the spa. The unit of mea-
surement is dH (degrees of hardness) and can be 0 - 9 soft,
9 - 21 hard, and 21+ extra hard.
Before calibrating the CHEMICAL TREATMENT device
ensure that the parameters entered match the properties
of the spa.
©pH settings
Setting the desired values:
1. In the main menu select SETTINGS, then the PARAMETERS
menu item.
2. Select the blue pH button on the right.
3. Adjust the pH value using the - and + buttons.
CALIBRATING THE pH PROBE OF THE CHEMICAL TREATMENT
DEVICE:
1. Check the pH value of your spa manually.
Use an Aseko tester.
Displayed value
-6,8
-6,8
-7,0
-6,8
-6,4
SUGGESTION:
We recommend a pH value of between 6.5 and 7.6.
- Use a low pH value if the spa is cleaned via active oxygen
system.
- Use a high pH value if the spa is cleaned via saltwater
electrolysis system.
- Use a pH value of 7.0 if the spa is cleaned via chlorine.
2. In the main menu of the CHEMICAL TREATMENT device
select SETTINGS, then the CALIBRATION menu item.
3. Select the blue pH button on the right.
4. Compare the data shown by the CHEMICAL TREATMENT
device with the results of the manual measurement.
If there is a difference, adjust the values shown by the
CHEMICAL TREATMENT device with the + and - buttons
until they match the manual results, then select OK to
save.
If the results of the manual test fall outside the 6.2 - 7.8 range,
you will receive the following notification.
If the difference between the results of the manual test and
the values shown electrically by the pH valve is greater than
0.3, you will receive the following notification.
pH buffer 7.00 #12065
SUGGESTION:
To finely calibrate use the 7.00 pH testbuffer.
User guide for the ASIN Aqua device.
Choose the function of your CHEMICAL TREATMENT device:
1. Free chlorine probe CLF
2. Redox electrode probe RX
3. Dosage based on time ml/m3 per hour or per day
In the main menu select SETTINGS, then the TYPE OF PROBE
to enter the next screen.
If you have a free chlorine probe:
Your CHEMICAL TREATMENT device is set up and connected
to the spa water and the chemicals.
Adjust the chlorine level to 0.0 mg/l.
Adjust the pH value to 7.0.
Manually adjust the chlorine level of your spa to between 0.5
and 1.2 mg/l via the manual dispenser of the ASIN Aqua or di-
rectly via the manual dispenser of your chlorine disinfectant.
Wait 24 hours for stabilization.
OPTIONAL ACCESSORIES  CHEMICAL TREATMENT
87
89

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Wellis In.Grid wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Wellis In.Grid

Wellis In.Grid Bedienungsanleitung - Deutsch - 124 seiten

Wellis In.Grid Bedienungsanleitung - Holländisch - 113 seiten

Wellis In.Grid Bedienungsanleitung - Französisch - 108 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info