Maintenance
33722 D MMG130DI4/175DI4/205DI4 Operating Manual 39
* Replace primary air cleaner when dust valve restriction indicator gauge shows a vacuum of 25 in. H
2
O.
** Change the oil and oil filter after the first 100 hours, then every 500 hours. If not using John Deere Plus 50 II
engine oil, the interval must be decreased to every 250 hours.
ENGINE BREAK-IN REQUIREMENTS
Note: During the first 20 hours of operation, avoid long periods of no load or sustained maximum load operation. If
the generator is to run for longer than five minutes without a load, shut the generator down.
John Deere engines are supplied with engine break-in oil from the factory. Extra care during the first 100 hours of
engine operation will result in better performance and longer engine life. DO NOT exceed 100 hours of operation
with the break-in oil. Operate the engine at heavy loads (60-90% of maximum) as much as possible. If the engine
has spent significant time at idle, constant speed(s), and/or light load, or if makeup oil is required, a longer break in
period may be needed. Refer to the engine operator’s manual for a full description of necessary procedures on the
addition of break-in oil and extension of the break-in period. For more information on regular maintenance intervals,
refer to Basic Maintenance Schedule - John Deere Engine.
RESETTING THE MAINTENANCE ALARMS
The Power Zone™ controller will display a warning message when the unit is due for maintenance or service. The
maintenance or service interval is set at 250, 500 and 3000 hours of engine running time. Once the unit has been
serviced, the appropriate maintenance alarm reminder needs to be reset. The following procedure demonstrates
how to reset the maintenance alarms:
1. With the unit shut down, move the control power switch to ON (I). After initialization, the controller will toggle
automatically to the Home screen.
2. Press any directional arrow (, , , ) to enter the maintenance screens.
3. Press the Enter () button and the Engine Stop/Reset (O) button simultaneously. The next screen will dis-
play the Configuration menu.
4. Press to move the cursor (blue highlighted text) down to the “Maintenance” group.
5. Press to access the sections. Press to highlight the “Maintenance” section.
6. Press to access the parameters and highlight the maintenance alarm that needs to be reset.
7. Press the Enter () button to select the editable parameters. The cursor will highlight “Not Reset” under the
selected maintenance alarm. Press to highlight “Reset”.
8. Press the Enter () button to reset the selected maintenance alarm.
9. To perform additional maintenance alarm resets, repeat steps 6 - 8.
Note: If the selected maintenance alarm does not need to be reset, press the button to highlight “Not Reset” and
press the Enter () button return to the parameters section.
Replace Air Cleaner Elements
Replace Alternator and Fan Belts
Check Fuses
Add Coolant
Check Electrical Wiring and Connections
Item Daily
250
Hrs.
500
Hrs./12
Months
3000
Hrs./ 36
Months
As
Required
45

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Generac MMG175DI4 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info