Disposal: The product must not be dis-
posed of along with other domestic waste.
The users must dispose of this equipment
by bringing it to a specic recycling point for
electric and electronic equipment.
Recommended separation distances between
portable and mobile
RF communications equipment and the EQUIP-
MENT or SYSTEM -for EQUIPMENT and SYS-
TEMS that are not LIFE-SUPPORTING
Guidance and manufacturer´s declaration –
electromagnetic immunity – for EQUIPMENT
and SYSTEM that are not LIFE-SUPPORTING
MANUFACTURER’S DECLARATION
OF THE EMC
Guidance and manufacturer´s declaration –
electromagnetic emission – for all EQUIPMENT
AND SYSTEMS
Guidance and manufacturer’s declaration –
electromagnetic immunity –for all EQUIPMENT
and SYSTEMS
• We will then repair or replace defective parts
or exchange the whole product as we select,
at no charge to the original owner. After such
repair, replacement or exchange, the product
will be warranted from the date of purchase.
This warranty is valid only if the Warranty Cer-
ticate and Warranty Registration Card are
duly complete with date of purchase, serial
number and dealer’s stamp, and if the Warran-
ty Registration Card is sent to local distributor
ofce not later than 14 days from the date of
purchase.
This warranty is void if this product has been
repaired or serviced by unauthorized person.
This warranty does not cover defects caused
by misuse, abuse, accident, tampering, poor
maintenance, re or any other acts beyond hu-
man control.
Except as stated in the above paragraphs,
A200 Infrared Thermometer disclaims all oth-
er warranties, implied or expressed, including
the warranties of merchantability of tness for
a particular purpose with respect to the use of
this product. Manufacturer shall not be liable
for any direct, consequential or incidental dam-
ages arising out of the use or inability to use
product.
REFERENCE OF STANDARDS
Device Standards:
Device Corresponds to the requirements of the
standard for infrared thermometers
IEC 60601-1-2: 2014
IEC 60601-1: 2012
ISO 80601-2-56: 2017
Classication:
Anti-electric Shock Type: Internally powered
equipment
Applied part: Type BF
Mode of operation: Continuous Operation
EMC: type B class I
Enclosure Degree of ingress protection: IP22
IP22 means shell of this product can withstand
the water dropping to the surface when the shell
deviate 15 degree from horizontal surface.
Electromagnetic Compatibility:
Device fullls the stipulations of the standard IEC
60601-1-2
The stipulations of EU-Directive 93/42/EEC for
Medical Devices Class II a have been fullled.
* Technical alterations reserved!
Software identify no.: A200 V1.1.0
WARRANTY
This thermometer is guaranteed for 18 months
from the date of purchase against any man-
ufacturing defect, conditional upon normal
household use.
The intended service life of the product is 24
months.
This product to be free of defects in workman-
ship and materials for a period on 18 months
from the date of purchase.
• During the warranty period, if this product is
found to be defective, you may bring it togeth-
er with the purchase receipt and Warranty Cer-
ticate on a carry-in basis to manufacturer’s of-
ce during normal business hours for warranty
service.
SPECIFICATIONS
SYMBOL INFORMATION
MAINTENANCE
Care & Cleaning
The probe is not waterproof. Please wipe
with a clean and dry cotton swab to clean
the probe on the inside.
The body of the thermometer is not water-re-
sistant. Never put the thermometer under a
running tap or submerge it into water. Use
a soft and dry cloth to clean it. Do not use
abrasive cleaners.
Store the thermometer in a cool and dry lo-
cation. Free from dust and away from direct
sunlight.
FAULT INDICATION
M25582-GB-Rev.0-04.20
25582 / A200
Shenzhen Aeon Technology Co., Ltd.
RM6H02, Block 27-29,
Tianxia IC Industrial Park, Majialong,
No.133 of Yiyuan road, Nantou Street,
Nanshan District, Shenzhen, China
Made in China
0123
Shanghai International
Trading Corp GmbH
Eiestrasse 80,
20537 Hamburg, Germany
FAULT OR
FAULT
SYMBOL
FAULT
DESCRIPTION
COR-
RECTIIVE
MEASURE
No display
On the LCD
pane
The battery has
run out. Incorrect
battery polarity.
Replace the
battery.
Please note:
The (+) side
of the battery
must face
upwards.
Measurement
not possible
(or an abnor-
mal value is
displayed)
The thermometer
is not ready.
Wait until the
°C symbol is
displayed.
An abnormal
temperature
value is
displayed.
The probe tip is
dirty or damaged.
Did you hear
the beep after
pressing the ON
button?
Clean the
probe tip or
get it repaired.
Wait until you
hear the
beep before
removing the
thermometer
from the ear
or forehead
LO or HI
symbol is
displayed
The temperature
measured is
outside the
measuring
Range.
LO-temperature
<32°C (89.6°F).
HI-tempera-
ture ≥42.9°C
(109.22°F).
Check that
the probe
tip is clean
and that the
thermometer
is properly
placed on the
forehead.
Symbol
is displayed
The battery has
run out.
Replace the
battery.
Symbol is
displayed
The ambient
temperature
is outside the
operating
temperature
range or is
changing too
fast.
To ensure
accurate
measurement,
let the ther-
mometer rest
at operating
temperature
for 30 minutes
prior to use.
Caution: read
instructions
(warnings) carefully
Medical Device
complies with
Directive 93/42/
EEC
Keep in a cool, dry
place
Keep away from
sunlight
Manufacturer Date of
manufacture
Product code Lot number
Follow instructions
for use
Type BF applied
part
Serial number WEEE disposal
Authorized
representative
in the European
community
Model A200
Measurement
range
Body/Forehead: 32.0~42.9°C
(89.6°F~109.22°F)
Object: 0.0°C to 99.9°C (32°F to
211.8°F)
Display
resolution
0.1°C / 0.1°F
Accuracy For body mode:
±0.2°C (±0.4°F) from36.0°C (96.8°F) to
39.0°C (102.2°F)
±0.3°C (±0.5°F) from 32.0°C (89.6°F)
to 35.9°C (96.6°F) and from 39.1°C
(102.4°F) to 42.9°C (109.22°F)
For object mode
±4°C (±7.2°F) from 0°C (32°C) to 4.9°C
(40.8°F)
±1°C (±2°F) from 5°F (41°C) to 60°C
(140.0°F)
±4°C (±7.2°F) from 60.1°C (140.1°F) to
100°C (212°F)
Indicator
light
Green light for temperature lower than
37.8°C(100.4°F)
Red light for temperature higher than
37.8°C(100.4°F)
Voice Power on and ready for working:
a short beep.
Measurement nished:
1 long beep equal or lower than 37.8°C
(100.4°F)
6 short beeps higher than 37.8°C
(100.4°F)
Memory Storage of 25 measurements
Operating
conditions
10°C to 40°C (50°F to 104°F),
Humidity: 15 to 95% R.H.
Air pressure 86Kpa-106Kpa
Storage and
transport
environment
Temperature: -25°C to 55°C
(-13°F to 131°F)F
Storage humidity: 15% to 95% RH
Auto shut-off About 30 seconds after no using
Battery 2pcs 1.5V AAA Alkaline Battery
Size 170 x 47 x 53 mm
Weight 75g
Guidance and manufacturer´s declaration –
electromagnetic emission
The A200 Infrared Thermometer is intended for use in
the electromagnetic environment specied below. The
customer or the user of A200 Infrared Thermometer
should assure that it is used in such an environment.
Emissions
test
Compli-
ance
Electromagnetic
environment - guidance
RF
emissions
CISPR 11
Group 1 The A200 Infrared Ther-
mometer uses RF energy
only for its internal func-
tion. Therefore, its RF
emissions are very low and
are not likely to cause any
interference in nearby elec-
tronic equipment.
RF emis-
sions
CISPR 11
Class B The A200 Infrared Ther-
mometer is suitable for
use in all establishments,
including domestic estab-
lishments and those direct-
ly connected to the public
low-voltage power supply
network that supplies
buildings used for domes-
tic purposes.
Harmonic
emissions
IEC
61000-3-2
N/A
Voltage
uctuations
/ icker
emissions
IEC
61000-3-3
N/A
Guidance and manufacturer´s declaration –
electromagnetic immunity
The A200 Infrared Thermometer is intended for use in
the electromagnetic environment specied below. The
customer or the user of the A200 Infrared Thermometer
should assure that it is used in such an environment.
Immunity
test
IEC 60601
test level
Com-
pliance
level
Electromagnetic
environment -
guidance
Electro-
static
discharge
(ESD)
IEC
61000-4-2
± 8 kV
contact
± 15 kV air
± 8 kV
contact
± 15 kV
air
Floors should be
wood, concrete or
ceramic tile. If
oors are covered
with synthetic ma-
terial, the relative
humidity should
be at least 30%.
Electro-
static
transient /
burst
IEC
61000-4-4
± 2 kV for
power
supply
lines
± 1 kV
for input/
output
lines
N/A
Mains power
quality should be
that of a typical
commercial or
hospital
environment.
Surge
IEC
61000-4-5
± 1 kV dif-
ferential
mode
± 2 kV
common
mode
N/A
Mains power qual-
ity should be that
of a typical com-
mercial or hospital
environment.
Voltage
dips,
short
interrup-
tions and
voltage
variations
on power
supply
input lines
IEC
61000-
4-11
0% UT;
0,5 cycle
g)
At 0°, 45°,
90°, 135°,
180°,
225°, 270°
and 315°
0% UT;
1 cycle
and 70%
UT; 25/30
cycles
at 0°
0% UT;
250/300
cycle
N/A Mains power qual-
ity should be that
of a typical com-
mercial or hospital
environment. If the
user of the A200 In-
frared Thermometer
requires continued
operation during
power mains
interruptions, it is
recommended that
the A200 Infrared
Thermometer be
powered from an
uninterruptible
power
Power
frequency
(50/60 Hz)
magnetic
eld IEC
61000-4-8
30 A/m 30 A/m Power frequency
magnetic elds
should be at levels
characteristic of
a typical location
in a typical com-
mercial or hospital
environment.
NOTE UT is the a. c. mains voltage prior to applica-
tion of the test level.
Guidance and manufacturer´s declaration – electromag-
netic immunity
The A200 Infrared Thermometer is intended for use in
the electromagnetic environment specied below. The
customer or the user of the A200 Infrared Thermometer
should assure that it is used in such an environment.
Immunity
test
IEC 60601
test level
Compli-
ance level
Electromagnetic envi-
ronment - guidance
Conducted
RF
IEC
61000-4-6
Radiated
RF
IEC
61000-4-3
3 Vrms
150 kHz to
80 MHz
6Vrms in
ISM banda
between
150 kHz to
80 MHz
80 MHz to
2.7 GHz
N/A
10 V/m
Portable and mobile
RF communications
equipment should be
used no closer to any
part of the A200 Infra-
red Thermometer, in-
cluding cables, than
the recommended se-
paration distance cal-
culated from the equa-
tion applicable to the
frequency of the trans-
mitter.
Recommended sepa-
ration distance
3.5
V 1
P
d=
3.5
E 1
P
d=
80 MHz to 800 MHz
7
E 1
P
d=
800 MHz to 2.5 GHz
Where p is the maxi-
mum output power
rating of the transmit-
ter in watts (W) ac-
cording to the trans-
mitter manufacturer
and d is the recom-
mended separation
distance in metres
(m).b Field strengths
from xed RF trans-
mitters, as determined
by an electromagnetic
site survey, a should
be less than the com-
pliance level in each
frequency range. b
Interference may oc-
cur in the vicinity of
equipment marked
with the fol-
lowing symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency
range applies.
NOTE 2 These guidelines may not apply in all situations.
Electromagnetic is affected by absorption and reection
from structures, objects and people.
a Field strengths from xed transmitters, such as base sta-
tions for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV
broadcast can not be predicted theoretically with accuracy.
To assess the electromagnetic environment due to xed
RF transmitters, an electromagnetic site survey should be
considered. If the measured eld strength in the location in
which the A200 Infrared Thermometer is used exceeds the
applicable RF compliance level above, the A200 Infrared
Thermometer should be observed to verify normal opera-
tion. If abnormal performance is observed, additional meas-
ures may be necessary, such as re¬orienting or relocating
the A200 Infrared Thermometer.
b Over the frequency range 150 kHz to 80 MHz, eld
strengths should be less than 3V/m.
Recommended separation distances between
portable and mobile RF communications equipment and the
A200 Infrared Thermometer
The A200 Infrared Thermometer is intended for use in an elec-
tromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of theA200 Infrared
Thermometer can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile
RF communications equipment (transmitters) and theA200 In-
frared Thermometer as recommended below, according to the
maximum output power of the communications equipment
Rated maxi-
mum output
of transmitter
W
Separation distance according to frequency
of transmitter m
150KHz
to 80MHz
3.5
V 1
P
d=
80MHz
to 800MHz
3.5
E 1
P
d=
800MHz
to 2.5GHz
7
E 1
P
d=
0.01 / 0.12 0.23
0.1 / 0.38 0.73
1 / 1.2 2.3
10 / 3.8 7.3
100 / 12 23
For transmitters rated at a maximum output power not listed
above the recommended separation distance d in metres
(m) can be estimated using the equation applicable to the
frequency of the transmitter, where P is the maximum output
power rating of the transmitter in watts (W) according to the
transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for
the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations.
Electromagnetic propagation is affected by absorption and
reection from structures, objects and people.
12
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gima A200 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info