607030
8
Zoom out
Zoom in
Vorherige Seite
1/16
Nächste Seite
Installation and
Operating Instructions
Door Station Stainless Steel
2501 20, 2502 20, 2503 20
2504 20, 2506 20, 2508 20
2509 20, 2510 20, 2512 20
3
Table of contents
Device description ......................................................................................................5
Installing panel box.....................................................................................................6
Installing front panel ...................................................................................................8
Start-up ......................................................................................................................9
Multi-function input ....................................................................................................9
Replacing inscription label ........................................................................................10
Opening Door Station Stainless Steel........................................................................12
Operation..................................................................................................................13
Technical data.......................................................................................................... 14
Warranty.................................................................................................................. 14
4
5
Device description
The Door Station Stainless Steel is a pre-assembled, vandalism-protected door station for
the Gira door communication system.
The front plate of high-quality V2A stainless steel with a thickness of 3 mm is especially
robust. The call buttons are also made of durable stainless steel. The illuminated inscrip-
tion labels are covered by a fully secured and flameproof glass plate. The inscription labels
can be opened via a covered mechanism and can then removed from the front.
Both the call buttons and inscription labels are uniformly illuminated with a white, power-
saving LED element.
Loudspeaker and microphone are located behind the respective sound openings and are
water-resistant and vandal-proof.
2
3
6
7
8
9
10
1
4
4
5
4
1 Wall anchors (included)
2Panel box
3Locking plate
4 Plastic bracket
5Catch strap hook
6Front panel
7Loudspeaker cover
8Microphone
9 Name plate
10 Call buttons
6
Installing panel box
1. Select a suitable installation site and chisel an
opening in the wall.
2. If necessary, mount the included wall anchor.
Note the following information when mounting the
panel box:
Ensure installation position is correct. (note the "TOP"
labelling).
The panel box must be installed level. With the later
mounting of the Door Station Stainless Steel there is
no possibility for correction.
The panel box must be installed as flush to the sur-
face as possible!
It must be ensured that the locking plate can be flush-
mounted later. Maximum plaster compensation is
20 mm.
3. Plaster in the panel box to be flush with the final
surface (maximum plaster compensation 20 mm).
Attention
Installation and mounting of electrical devices may
only be carried out by a qualified electrician.
max.
20 mm
7
4. Mount the included plaster protection.
5. Plaster the wall.
6. Carefully remove the plaster and take out the plas-
ter protection.
8
Installing front panel
1. Insert the locking plate flushly into the panel box.
Push the locking plate inwards until the plastic
brackets touch the wall.
2. Fasten the locking plate with the 4 Allen bolts and
locking washers included.
In order to guarantee a secure fastening of the front
panel later, the Allen bolts must be firmly tightened.
3. Fold out both lateral mounting retainers (1.), slide
the front panel of the Door Station Stainless Steel
into the mounting retainers (2.) and attach the catch
strap of the front panel to the hook of the locking
plate (3.).
4. Connect the 2-wire bus to the Bus terminals.
i
Insert locking plate evenly
The locking plate must not be twisted while being
inserted into the panel box and must not be under
tension.
2.
1.
3.
ZV BUS
i
9
Starting up
Once all of the devices (door and home stations, control device etc.) have been installed,
the door communication system can be started up.
Start-up a door station is described in the system manual included with the control device.
Multi-function input
A mechanical push button can be connected to the
multi-function input of the stainless steel door
station's built-in loudspeaker via the included connec-
tion cable.
The push button then has the same function as a call but-
ton and can therefore be used, for example, as a call but-
ton or for controlling a switching actuator.
5. Pull the front panel from the mounting retainers (1.)
and fold these in (2.).
6. Position the (lower) fastening bolt(s) of the front
panel to "Close".
7. Mount the front panel onto the guide bolts and
press it on until the upper and lower fastening bolts
engage.
1.
2.
Open
Close
10
Replacing inscription label
Inscription labels
For labelling the Gira Door Station Stainless Steel, use only Gira inscription labels.
The transparent plastic labels are non-fading, weather-resistant and wrinkle-free.
With the included release code, inscription labels for the first labelling are available free
at www.marking.gira.com
1. Unlock the call button with the enclosed plastic key:
twist the plastic key anti-clockwise until it engages.
2. Engage the call button:
press the call button firmly inwards by approx. 1 cm.
The call button engages and stays in the pressed
position.
3. Grip under the glass cover with the flat side of the
plastic key and twist out the inscription label carrier.
4. Remove the existing inscription label and slide the
new inscription label into the inscription label carrier
until it stops.
120°
c
l
i
c
k
c
l
i
c
k
1 cm
Do not remove the inscription label carrier.
Do not lift and remove the inscription label carrier!
M
u
s
t
e
r
m
a
n
n
11
5. Position the inscription label underneath the clips of
the inscription label carrier.
6. Slide in the inscription label carrier again.
At the same time, position the inscription label with
your finger.
7. Release the call button:
To do this, press in the plastic key slightly and turn it
clockwise until the call button is released from the
lower position.
8. Lock the call button:
To do this, turn the plastic key clockwise again until
it engages.
9. For function test, press the call button:
the call button is correctly locked when
•the call button cannot be pressed in deeply and
an acknowledgement tone is heard when the call
button is pressed.
If the call button is not correctly locked, please repeat
step 8.
ustermann
c
l
i
c
k
ustermann
c
l
i
c
k
12
Opening Door Station Stainless Steel
The included opening tool is required for opening the
Door Station Stainless Steel.
1. Turn the (lower) fastening bolt(s) with the opening
tool to "Open".
Single-column door stations have one lower fasten-
ing bolt, double-column door stations have two
lower fastening bolts.
The position of the fastening bolts is shown via
small recesses on the lower side of the front panel.
2. Lift the front panel from the lower attachment (1.)
and pull it at an angle downwards from the upper
attachment retainers (2.).
90°
Open
90°
Open
90°
Open
Take care with plastered walls
With repeated opening of the door station with
plastered walls, the opening tool may damage the
plaster.
2.
1.
13
Operation
Volume setting
The volume can be set separately at each door station.
The volume setting must be made by two people.
Initiating a call (ringing)
Switching light on (in conjunction with a switching actuator)
1. Press the "Systemprogr." button on the control device for 3
sec. to start programming mode.
2. Briefly press a previously assigned call button at the door
station.
3. The second person accepts the door call at the home station
(via receiver or speech button) and starts speaking.
4. Briefly press the call button again at the door station.
Volume changes during the voice connection when the button
is pressed.
There are four volume levels in total.
The next-highest volume is set with each button press. When
the loudest volume level is reached, the next button press sets
the quietest volume level.
5. Ending the voice connection.
The most recently set volume level is saved in the door sta-
tion.
6. Briefly press the "Systemprogr." button on the control device
to exit the programming mode.
1. Press the call button to trigger a call tone at the assigned
home station.
The button press is confirmed by an additional acknowledge-
ment tone.
If the conversation is accepted by the home station, the micro-
phone opening is illuminated blue.
1. Press the call button to switch on light or another device via
an assigned switching actuator.
The button press is confirmed by an additional acknowledge-
ment tone.
1 x
M. Meier
1 x
M. Meier
M. Meier
Licht
14
Technical data
Connections: 2 screw terminals for 2-wire bus
2 screw terminals for additional supply
2 system bus connector strips (6-pole)
1 video connector strip (2-pole)
2 sabotage contact screw terminals
Protection type: IP 44
Operating temperature: -25 °C to +70 °C
Dimensions (W x H x D):
1-gang, 2-gang, 3-gang: 140 x 198 x 40 mm (panel box)
160 x 218 x 3 mm (front panel)
4-gang, 6-gang: 140 x 265 x 40 mm (panel box)
160 x 285 x 3 mm (front panel)
8-gang, 9-gang: 140 x 332 x 40 mm (panel box)
160 x 352 x 3 mm (front panel)
10-gang, 12-gang: 250 x 265 x 40 mm (panel box)
270 x 285 x 3 mm (front panel)
Warranty
The warranty is provided in accordance with statutory requirements via the specialist
trade.
Please submit or send faulty devices postage paid together with an error description to
your responsible salesperson (specialist trade/installation company/electrical specialist
trade).
They will forward the devices to the Gira Service Center.
Gira
Giersiepen GmbH & Co. KG
Elektro-Installations-
Systeme
Postfach 1220
42461 Radevormwald
Deutschland
Tel +49 (0) 21 95 / 602 - 0
Fax +49 (0) 21 95 / 602 - 191
www.gira.de
info@gira.de
10 41 09 22 20/11
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gira 251020 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Gira 251020

Gira 251020 Bedienungsanleitung - Deutsch - 16 seiten

Gira 251020 Bedienungsanleitung und Installationsanweisung - Holländisch - 16 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info