9. STOVE WITH SELF CLOSING DOOR.
As our stoves have self-closing doors (fitted with a resisting spring) it is
possible to have more stoves connected to the same chimney.
All stoves must be fitted with a self-closing door.
To make sure this connection is possible please contact a chimney sweeper.
The fire must not be lit with an open door.
If the other stoves do not have a self-closing door or they are open fires it is
not possible to connect more stoves to one chimney.
In this case the chimney draught is not correct and the room could fill with
smoke.
10. FRESH AIR FLOW FOR MAXIMUM COMBUSTION.
If your house is fitted with a mechanical ventilation system it is necessary to
use an external air flow which can be fitted on to the rear of the stove.
Problems can also occur if an extractor hood with a high extraction capacity
is fitted in your kitchen and the house is well insulated.
Too much air will be taken out of the room causing smoke to be extracted
from the stove.
This can be solved by placing an automatic switch in your extractor hood
which only works with a window open.
These can be supplied by your electrician.
12. FIRE SAFETY DISTANCES.
Furniture and flammable wall.
The distance from the back of the stove is 20 cm.
From both sides 40 cm.
From the glass 80 - 100 cm.
Floor.
A flammable floor ( carpet, wood etc. ) must be protected by a fireproof plate that is 30 cm
wider on both sides and at least 50 cm in front.
Each type of stove may have different regulations.
The distances required for your stove are found by consulting the page on types of stoves
in your user’s manual.
13. PARTS.
It is only possible to replace parts with original parts belonging to the stove.
These parts can be ordered through your supplier.
The fireplace must under no circumstances be altered in any way.
11. ACTION TO BE TAKEN BY A CHIMNEY FIRE.
Using wet wood, burning at low temperatures or using the wrong sorts of fuel can
cause a depository of soot in the chimney.
This can result in a chimney fire.
In this case close all air vents and contact the fire brigade.
After the fire, get your chimney sweeper to check for any cracks that may have
occured and sweep the chimney.
14. CAPACITY.
This stove has been tested at 7 kW.
When adding fuel it is recommended not to use more than 3 blocks of wood.
When using brown coal use only 3 or 4 briquettes.
Do not open the stove door before the wood has burnt to a glow and
flames are no longer visible !!!
7.
6.
15. CAPACITY.
Capacity, depending on the building material used for your house and tested according
to European and German requirements:
Favourable conditions - 120-150
Average conditions - 120
Unfavourable conditions - 82 m ³
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Globe Fire Acturus I wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Globe Fire Acturus I

Globe Fire Acturus I Bedienungsanleitung - Deutsch - 8 seiten

Globe Fire Acturus I Bedienungsanleitung - Holländisch - 8 seiten

Globe Fire Acturus I Bedienungsanleitung - Französisch - 8 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info