Before putting into operation, observe Chapter 2 “For your safety”.
Danger to health due to escaping spraying pesticides! A leaking device or
leaking components may result in draining or spouting of spraying pesticides. You should
therefore observe the following safety instructions:
! Prior to each use, check the device to ensure fault-free condition and leak-tightness.
To perform the leak test, fill the container with water!
! Inspect all screw joints for tight fitting.
6.2 5/10 litre devices >> 6.1.1 Inspecting the safety valve
figures
–
6.1.2 Venting the container, draining the water and filling with spraying pesticides >>
figures
–
! Activate the safety/vent valve – red button – until the device is depressurised.
! Prior to filling the sprayer, observe the instructions relating to particular hazards (R-phras-
es/German Hazardous Substances Ordinance [GefStoffV]) and safety advice (S-
phrases/German Hazardous Substance Ordinance [GefStoffV]) that are provided on the
chemical containers according to regulations.
! Observe max. fill level (see technical data). The regulations of the spraying agent manufac-
turer specify the correct dosage and concentration.
>>
figure
Use the supplied filling strainer for filling the tank. The filling strainer
supplied should be used for pre-filtration, especially when spraying pesticides are applied and particu-
larly when powder-based concentrates are used.
6.2 Spraying >>
figures
–
You may be exposed to hazards that could injure you when handling the
device and the spraying pesticides. You must therefore always comply with the safety instruc-
tions/safety measures in this user manual, as well as the following instructions:
! The device must only be operated when suspended in a vertical or steep upright position.
! Pressing the actuation lever down on the quick closure valve initiates the spraying process. This
can be interrupted immediately by releasing the actuation lever.
! The pumping procedure makes it possible to influence the spray pressure at the nozzle.
! Perform re-pumping if the spray pressure falls.
! In order to ensure that the spray pressure is as even as possible and that the spray cycle is as long
as possible, the 'pressure regulator on the quick closure valve' * must be set (see figure 19) to the
prescribed spray pressure (see nozzle table, Chapter 7.1).
! If the pressure in the container falls below the set pressure, pump a little to ensure uniform
spraying of the liquid.
! Ensure uniform wetting of the objects when spraying.
! A higher pressure must be set on the pressure regulator when using special spray pipes (exten-
sion pipes, wide spray pipes, etc.).
* Only for device versions 410T and 510T.