SYSTEM CHARACTERISTICS
UPDATED FEATURES FROM 5.00 VERSION
STARTING RECOMMENDATIONS
O Management of up to 255 internal buildings of 1,000 apartments each.
O New programming menu structure.
O Direct Call Code that allows to use a different call code from the one recorded on the monitor or
telephone (page 116).
O 'Repertory:insert' function, that allows to keep sorted the repertory content (page 122).
O Transmission of the repertory content to other panels or porter's exchanges through the
installation wires (page 123).
O Third access control code with time restriction (page 120).
O Text edition using the keypad as a mobile phone (page 124).
O Previous software versions are fully compatible, except when the Direct Call Code is
activated or the number of internal buildings is bigger than 99.
106
O
O
O
O
O
Do not use excessive force when tightening the power supply connector screws.
Install the equipment without the power connected. Disconnect from power before any system
modification. Check that the input voltage is lower than 230Va.c.
Before to connect the system, check the connections between door panel, monitors and
telephones, and the transformer connection. Do always follow the enclosed information.
Each time the power supply is restarted, or after a modification, the system will remain blocked
during 30 seconds.
Always use RG-59 or RG-11 coaxial cables. Never use coaxial antenna cable. In
installations no longers than 100m., Golmar RAP-5130 cable can be used.
O Microprocessed systems with bus installation (no call wires):
wAudio system with 4 common wires installation.
wVideo system with 3 common wires plus coaxial cable.
wVideo system with 4 common wires plus twisted pair cable.
O Unlimited number of door panels being not necessary the use of switching units.
Acoustic busy channel and call acknowledgement signals.
d.c. lock releases activation.
Timed door open activation.
In Platea Uno monitors or T-940 Uno and T-740 Uno telephones:
wPrivacy on audio and video communications.
w'Video-Spy' function remaining the communication channel free.
wInput for door bell apartment push button.
wUp to three monitors or telephones in the same apartment without additional power supplies.
wIn Platea Plus monitors or T-940 Plus telephones, besides the aforementioned characteristics:
wIntercommunication function with other monitor or telephone of the same apartment.
wDifferent call reception tones depending where the call is comming from: main or slave door
panels, door bell push button, intercom, ....
wActivation of two auxiliary devices: secondary telecamera, courtesy light, ...
O
O
O
O
SYSTEM OPERATION
One building systems.
O To make a call, the visitor should key-in the three digits code corresponding to the apartment he
wishes to contact: the door panel display will show the sequence keyed-in. Once the code has
been introduced, press bell key to confirm the call: acoustic tones will be heard confirming the call
is in progress and the door panel display will show the message calling. At this moment the
call will be received at the monitor (telephone) in the dwelling. If an incorrect code has been
keyed-in, press key and try again.
In systems with several access doors, the other(s) door panel(s) will be automatically disconnected:
if a visitor tries to call from other door panel an acoustic tone will be heard confirming the system
is busy and the door panel display will show the message busy.
The call tone will be reproduced on the monitor during 3 seconds: after this time the picture will
appear on the master monitor without the visitor being aware of this. To see the picture in a slave
monitor press the push button, dissapearing the picture on the other monitor. If the call is not
answered in 45 seconds, the system will be freed.
O To establish communication pick up the monitor (telephone) handset. The communication will last for
one and a half minutes or until the handset is replaced. During the communication the door panel
display will show the message communication. Once the communication has finished the
system will be freed.
O To open the door, press the door release push button during call or communication progresses: with
one press, the door release operates during the programmed time. During the lock release
activation an acoustic tone will be heard on the door panel confirming the lock release is
activated, and the door panel display will show the message door opened.
O The monitor and telephone push buttons description is shown on pages 127 and 133 respectively.
Systems with general entrance door panel(s) and several internal buildings.
O To make a call from a general entrance door panel, the visitor should key-in the five digits code
corresponding to the apartment building he wishes to contact: the door panel display will show the
sequence keyed-in. Proceed as described on the previous paragraph to establish the call progress.
The corresponding internal door panel and the other general entrance door panels (if exist): if a
visitor tries to call an acoustic tone will be heard confirming the system is busy, and the door panel
display will show the message busy. The rest of door panels are free to establish communication.
O To make a call from an internal door panel proceed as described on the previous paragraph. The
rest of internal door panels are free to establish communication. A call from the general
entrance door panel can be made to any of the internal buildings, except to the one is in
communication.
Use of the repertory names.
O If the visitor don't know the code of the apartment he wishes to contact, he could find it on the
repertory name by searching through the arrow keys. Once the code has been found, the call can
be made by pressing the bell key. Refer to page 124 for details about fast repertory searching.
Lock release activation using the access control.
O To open the door using the access control facility, press KEY symbol and one of the valid access
codes. During the lock release activation an acoustic tone will be heard on the door panel
confirming the lock release is activated, and the door panel display will show the message
door opened. If an incorrect code has been keyed-in, press key and try again. The
introduction of three wrong consecutive codes freezes the access control during 60 seconds.
107
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Golmar 5403 Stadio Plus - T3403ML wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Golmar 5403 Stadio Plus - T3403ML

Golmar 5403 Stadio Plus - T3403ML Bedienungsanleitung - Englisch - 160 seiten

Golmar 5403 Stadio Plus - T3403ML Bedienungsanleitung - Holländisch - 24 seiten

Golmar 5403 Stadio Plus - T3403ML Installationsanweisung - Holländisch - 52 seiten

Golmar 5403 Stadio Plus - T3403ML Bedienungsanleitung - Französisch, Spanisch - 160 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info