TELEPHONES PROGRAMMING
rogramming the
P
telephones.
Set to ON the switch number 2 of the configuration dip switch, that's
accessible by opening the terminal connector protection cover.
The door panel will reproduce a sound to advise that the system
has entered into programming mode.
In systems with more than one door panel, the programming process
shall be done on the master door panel only.
Switch off the telephone to be programmed.
Once the telephone is off, press the door release push button.
With the door release push button pressed
switch on the telephone.
To show that the system is ready for programming,
the door panel will reproduce a sound and
the telephone led will blink. At this moment, the door
release push button can be released. Lift the handset
to establish audio communication with the door panel.
Press the door panel push button that will
call to this telephone. At this moment
the door panel will reproduce a sound
and the telephone led will blink.
To program the telephone as master,
switch it off and on again.
To program it as slave, press the door
release push button.
To program it as slave with intercom
function press the center push button.
Each apartment must have one master unit only; in case of parallel units configure them
as slaves, both monitors or telephones.
Make a call to check that the telephone has been succesfully programmed.
Repeat these steps to program the rest of telephones.
Once the programming has been finished, set to OFF the programming
switch. If you don't, the door panel will reproduce a sound to advise
that the system is still into programming mode.
MRBO T
R-3
TF-104
SEC
~~
CV+CV- D
Malla
Vin-AinAout Vin+ Vout-Vout++
CN1
-
INSTALLATION DIAGRAMS
onnexion of an a.c. lock release.
C
As it is described on page 14, the lock releases to be connected to the door panel
must be d.c. type. If an a.c. lock release has been installed before, use a R-3
relay unit and a TF-104 transformer, and connect them to the lock release
as it is shown on the enclosed diagram.
ink of several power supplies units.
L
If the quantity of monitors or telephones to be connected is bigger than the supported
from one power supply (see page 14), use additional power supplies to match the
required quantity. The first power supply should be connected to the door panel and
to the first group of monitors or telephones; connect the next groups to the positive
terminal of its corresponding power supply.
To wire several power supplies link their ground terminals;
NEVER link positive terminals of different power supplies.
To the door panel and to
the first group of monitors
or telephones.
To the second group of
monitors or telephones.
1st FA-Plus 2nd FA-Plus/C or FA-Plus
SEC
PRI
~~
Main
+ +
--
SEC
PRI
~~
Main
+ +
--
Door panel
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Golmar Stadio Plus T500EN wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info