590621
4
Zoom out
Zoom in
Vorherige Seite
1/4
Nächste Seite
A~ / Hz / A / A CF /
Messung mit Zangenstromsensor
Measurement with Current Clamp Sensor
A~ / Hz A / A CF
Messung mit Zangenstromsensor
Measurement with Current Clamp Sensor
A~ /
Messung mit Zangenstromsensor
Measurement with Current Clamp Sensor
W, VA, VAr, PF Wh, VAh, VArh
Wirk-, Schein- und Blindleistung
Active, Apparent and Reactive Power
W, VA, VAr, PF
Wirk-, Schein- und Blindleistung
Active, Apparent and Reactive Power
Wh, VAh, VArh
Wirk-, Schein- und Blindenergie
Active, Apparent and Reactive Energy
CLiP = 1:1/10/100/1000 ! SETUP
Übertragungsfaktor
Transformation factor
CLiP
Messbereiche
Measuring Ranges
Zange
Current clamp
600 mV 6 V 60 V
1:1
1mV/1mA
0,6 A 6 A 60 A WZ12C
1:10
1mV/10mA
6 A 60 A 600 A
WZ12B, Z201A/B,
METRAFLEX
1:100
1mV/100mA
60 A 600 A 6000 A
Z202A/B,
METRAFLEX
1:1000
1 mV/1 A 600 A 6000 A 60000 A
WZ12C, Z202A/B,
Z203A/B,
METRAFLEX
Hz (A ):
0,01 Hz
60 kHz
V~
1kHz
dB
V
V
[PQ]
~
R
x
Strom
Current
COM
V
Temp
R
i
R
i
9 M
R
i
17 M
(DC)
> 600 V:
> 30 V AC
/ > 35 V DC
:
max. 600 V (< 10 kHz)
!
max. 100 V (> 10 kHz)
P
max
= 6 x 10
6
V x Hz
CLiP = 1:1/10/100/1000 ! SETUP
V~
1kHz
dB
A~
100
.
50
A
AC
TRMS
Hz
1:1000
Hz
050
.
00
Hz
AC
TRMS
1:1000
FUNC
ENTER
050
.
00
Hz
CLiP = 1:1/10/100/1000 ! SETUP
CF
FUNC
ENTER
000
.
00
A
DC
AC
TRMS
A
1:1000
000
.
00
A
DC
A
1:1000
Cf
:
01
.
0
V
V
[PQ]
CLiP = 1:1/10/100/1000 ! SETUP
000
.
0
%
AC
TRMS
thd
:
000
A
1:1000
MAN / AUTO
DATA/MIN/MAX
000
.
0
%
AC
TRMS
harm
:
2 000
A
100
.
0
%
AC
TRMS
harm
:
1 000
A
MAN / AUTO
DATA/MIN/MAX
ZERO
ESC
Harmonische: 3 ... 15
Harmonic: 3 ... 15
1:1000
1:1000
set > harm > harm .f: 16 .7 /50 /60 /400 Hz
Parameter Oberschwingungsanalyse:
Parameter Harmonic Analysis:
SETUP
CLiP = OFF SETUP
W
Wh
–/N
+/L
~
COM
V
Tem p
AmA
COM
V
Tem p
AmA
N
L
~
Anschluss
Connection
10 A (max. 5 min)
Überlastbarkeit @ 600 V:
Overload @ 600 V:
16 A (max. 30 s)
R
x
R
x
CLiP = 1:1/10/100/1000 SETUP
W
Wh
000
.
00
W
DC
AC
TRMS
W
000
.
0
mV
000
.
0
mA
VA
000
.
00
VA
DC
AC
TRMS
pf
:
0
.
00
VAr
μ
μ
000
.
00
DC
AC
TRMS
000
.
0
mV
000
.
0
mA
VAr
μ
MAN / AUTO
DATA/MIN/MAX
MAN / AUTO
DATA/MIN/MAX
MAN / AUTO
DATA/MIN/MAX
Messbereiche W:
Measuring Ranges:
3,6 mW / 36 mW
360 mW
3,6 W / 36 W
360 W
3,6 kW / 6 kW /
36 kW* / 360 kW* /
3,6 MW*
Bandbreite:
... 1 kHz
Bandwidth:
* nur mit Zangen-
stromwandler
only with current
clamp transformer
FUNC
ENTER
10
Wh ... 1 GWh
Anzeigebereiche Wh:
Display Ranges:
Bandbreite:
... 1 kHz
Bandwidth:
0
.
00000
Wh
DC
AC
TRMS
Wh
energy
00
:
00
:
00
VAh
0
.
00000
VA
DC
AC
TRMS
VArh
μ
0
.
00000
DC
AC
TRMS
VArμ
MAN / AUTO
DATA/MIN/MAX
MAN / AUTO
DATA/MIN/MAX
MAN / AUTO
DATA/MIN/MAX
ON
h
h
μ
W
Wh
energy
00
:
00
:
00
ON
energy
00
:
00
:
00
ON
W VA, PF
Wirkleistung Scheinleistung
Active Power Apparent Power
VAr
Blindleistung
Reactive Power
Wh VAh
Wirkenergie Scheinenergie
Active Energy Apparent Energy
VArh
Blindenergie
Reactive Energy
W
000
.
00
Wh
DC
AC
TRMS
Wh
energy
Wh
00
:
00
:
00
W
000
.
00
DC
AC
TRMS
W
000
.
00
DC
AC
TRMS
MAN / AUTO
DATA/MIN/MAX
FUNC
ENTER
ON
mean
00
:
00
:
00
00
.
00
.
00
00
:
00
:
00
MAN / AUTO
DATA/MIN/MAX
MAN / AUTO
DATA/MIN/MAX
ON
max
Leistungsmittelwerte
Maximale Leistungsmittelwerte
Energiewerte
000
.
00
DC
AC
TRMS
VAh
energy
00
:
00
:
00
VA
000
.
00
VA
DC
AC
TRMS
VA
000
.
00
DC
AC
TRMS
VA
MAN / AUTO
DATA/MIN/MAX
ON
mean
00
:
00
:
00
00
.
00
.
00
00
:
00
:
00
MAN / AUTO
DATA/MIN/MAX
MAN / AUTO
DATA/MIN/MAX
ON
max
000
.
00
DC
AC
TRMS
VArh
energy
00
:
00
:
00
VAr
000
.
00
VAr
DC
AC
TRMS
VAr
000
.
00
DC
AC
TRMS
VAr
MAN / AUTO
DATA/MIN/MAX
ON
mean
00
:
00
:
00
00
.
00
.
00
00
:
00
:
00
MAN / AUTO
DATA/MIN/MAX
MAN / AUTO
DATA/MIN/MAX
ON
max
W>Wh
W
W
VA h
VAr
h
μ
μ
μ
μ
μ
μ
μ
μ
μ
Mean values of power
Maximum mean values of power
Energy values
ZERO
ESC
= alle Werte löschen
= delete all values
Reset
SETUP
EnErGY > dEMAnd time
Betrachtungszeitraum / Period under Review
lang
long (1 s)
W
W
Wh
W
000
.
00
DC
AC
TRMS
W
000
.
00
DC
AC
TRMS
MAN / AUTO
DATA/MIN/MAX
24
.
02
.
10
04
:
21
:
56
24
.
02
.
10
05
:
33
:
01
MAN / AUTO
DATA/MIN/MAX
MAN / AUTO
DATA/MIN/MAX
max
Minimalwerte
Maximalwerte
Momentanwerte
000
.
00
DC
AC
TRMS
VA
pf
:
0
.
00
VA
000
.
00
VA
DC
AC
TRMS
VA
000
.
00
DC
AC
TRMS
VA
MAN / AUTO
DATA/MIN/MAX
24
.
02
.
10
05
:
33
:
01
MAN / AUTO
DATA/MIN/MAX
max
VAr
000
.
00
VAr
DC
AC
TRMS
VAr
000
.
00
DC
AC
TRMS
VAr
MAN / AUTO
DATA/MIN/MAX
24
.
02
.
10
05
:
33
:
01
MAN / AUTO
DATA/MIN/MAX
max
W
W
000
.
00
W
DC
AC
TRMS
000
.
0
mV
000
.
0
mA
VAr
000
.
00
DC
AC
TRMS
000
.
0
mV
000
.
0
mA
min
lang
24
.
02
.
10
04
:
21
:
56
min
24
.
02
.
10
04
:
21
:
56
min
MAN / AUTO
DATA/MIN/MAX
MAN / AUTO
DATA/MIN/MAX
μ
μ
μ
μ
μ
μ
μ
VA
μ
VAr
μ
Minimum values
Maximum values
Momentary values
long
lang
long
lang
long
ZERO
ESC
= alle Werte löschen
= delete all values
Reset
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gossen Metrawatt METRAHIT ENERGY wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Gossen Metrawatt METRAHIT ENERGY

Gossen Metrawatt METRAHIT ENERGY Bedienungsanleitung - Englisch - 98 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info