590607
2
Zoom out
Zoom in
Vorherige Seite
1/3
Nächste Seite
Diodentest
Diode Testing
V / V
Gelijk- / mengspanningsmeting
Direct Voltage / Pulsating Voltage Measurement
V~/ Hz
Wisselspanning – Frequentie, zonder/met laagdoorlaatfilter
AC Voltage – Frequency, without/with Low-pass Filter
m
Capaciteit
Kabellengtemeting
Capacitance Cable Length Measurement
A / A
Gelijkstroom- / mengstroommeting
DC / Pulsating Current Measurement
A~ / Hz
Wisselstroom- / frequentiemeting
Alternating Current / Frequency Measurement
COM mA A
V
Temp
aEb
Doorstroomrichting
Sperrichting
0V !
0.654
0.L
... 5,1 V
+
0.443
V
!
DC
Meetbereik:
Measuring Range:
Conducting Direction
Reverse Direction
FUNC
ENTER
000.8
R
SL
COM mA A
V
Temp
aEb
– (+)
+ (–)
V= : 100 V 610 V
020.00
V
DC
AC
TRMS
020.00
V
DC
V
V
V
V
Meetbereiken:
> 15 V AC of/or > 25 V DC:
> 610 V:
Waarschuwingen voor gevaarlijke spanningen:
230
.
0
Caution! Dangerous Voltages:
Measuring Ranges:
max. 600 V (< 10 kHz)
!
P
max
= 6 x 10
6
V x Hz
FUNC
ENTER
V : 10 mV610 V
CLiP = OFF ! SETUP
COM mA A
V
Temp
aEb
max. 600 V (< 10 kHz)
V~: 10 mV 610 V
Hz: 1Hz 300 kHz
~
!
>610V:
0225.6
V
AC
TRMS
0049.9
Hz
AC
V~
Hz
V~
Hz
V~/Hz & Filter
P
max
= 6 x 10
6
V x Hz
V~ FilFilter actief / active
Hz FilFilter actief / active
Meetbereiken:
Measuring Ranges:
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
CLiP = OFF ! SETUP
COM mA A
V
Tem p
aEb
10.38
F
0V !
!
+
+
10 pF ... 310 F
m
FUNC
ENTER
15.00
m
m
3.100 km/31.000 km
Meetbereiken:
Measuring Ranges:
COM mA A
V
Temp
aEb
k
Setup CAP
Kabeltype = constant !
!
Cable type = constant !
COM mA A
V
Tem p
aEb
~
R
x
~
R
x
1
3
2
Zekering
Fuse
FF 1,6 A / 700 V AC DC
6,3 mm x 32 mm
A
A
003.50
m A
DC
003.50
m A
DC
AC
TRMS
A
A
8
.
8
.
8
.
8
.
8
!
Stroom
Current
Meetbereiken:
Measuring Ranges:
FUNC
ENTER
!
I > 1,1 A
A: 0,1 A . .. 1,1 A
A: 3 A . .. 1,1 A
COM mA A
V
Tem p
aEb
Stroom
Current
~
R
x
~
R
x
1
3
2
A~
Hz
A~
Hz
003.50
m A
AC
TRMS
0049.1
Hz
AC
8
.
8
.
8
.
8
.
8
!
Zekering
Fuse
FF 1,6 A / 700 V AC DC
6,3 mm x 32 mm
Meetbereiken:
Measuring Ranges:
FUNC
ENTER
Hz: 1Hz
30 kHz
!
I > 1,1 A
A ~: 3 A . .. 1,1 A
A / Hz
Meting met stroomtang
Measurement with Current Transformer Clamp
M ISO @ 100 V / Hz
Isolatieweerstandsmeting
Insulation Resistance Measurement
Apparaat- en meetparameters SETUP
Device and Measuring Parameters
Technische gegevens – Technical Data
1)
bij / at 0 C...+40C
2)
als functie ZERO actief / with function ZERO active
3)
Vermogensbegrenzing /
Power limiting:
6 · 10
6
V · Hz (max. 600 V 1 kHz)
4)
voor maximale stroomwaarden, zie Stroommeetbereiken
max. current values see current measuring range
Elektrische veiligheid – Electrical Safety
Beschermingsklasse / Protection class II
– volgens /
per
IEC 61010-1:2010/EN 61010-1:2010/VDE 0411-1:2011
Meetcategorie / Measuring Category CAT I I / CAT III
Nominale spanning / Nominal Voltage 600 V / 300 V
Verontreinigingsgraad / Pollution degree 2
Testspa n ning / Te st Vol t age 3,5 kV~
– volgens / per IEC 61010-1/EN 61010-1
IP-classificering / Protection
– Behuizing / Housing: IP54 (drukcompensatie door
behuizing/pressure equalization
by means of the housing)
Tabellenuittreksel over de betekenis van de IP-code
Extract from table on the meaning of IP codes
Elektromagnetische compatibiliteit EMC
Electromagnetic Compatibility EMC
Storingsuitzending / Interference Emission
EN 61326-1:2006 Klasse B / class B
Storingsbestendigheid / Interference Immunity
EN 61326-1:
2006
EN 61326-2-1:
2006
Omgevingsomstandigheden – Ambient Conditions
Nauwkeurigheidsbereik / Accuracy range 0C ... + 40 C
Werktemperatuur / Operating temperature –10 C ... + 50 C
Opslagtemperatuur /
Storage temperature
zonder batterij / without battery – 25 C ... + 70 C
Relatieve luchtvochtigheid / relative humidity 40 ... 75 %
Geen condens toegestaan / no condensation allowed
Hoogte boven NAP tot / Elevation up to 2000 m maximum
Zekering – Fuse
FF(ultrarapid) 1,6 A / 700 V AC DC
6,3 mm x 32 mm
Uitschakelvermogen /
breaking capacity
: 50 kA (Min 10 kA)
Bij gebruik van een andere zekering vervalt de fabrieksgarantie.
If you use other fuses than the one indicated above you forfeit
your product guarantee.
Interne zekeringentest –
Internal Fuse Test
Zekering vervangen – Fuse Replacement
Koppel het apparaat van de meetkring af voordat u
het deksel van het zekeringenvakje openmaakt! Draai
daartoe de spleetschroef naar links. Deze kan niet ver-
loren gaan.Licht de zekering met de vlakke zijde van
het zekeringendeksel uit het vakje.
Als u het zekeringendeksel weer inzet, moet u de zijde met de
geleidehaken er het eerst inzetten.
Draai de spleetschroef naar rechts in.
Disconnect the instrument from the measuring circuit
before opening the fuse compartment lid! Turn the
(captive) slotted head screw counter-clockwise for
this purpose. Remove the fuse with the flat end of the
fuse compartment lid.
When refitting the fuse compartment lid the side with the guide
hooks must be inserted first. Then turn the slotted head srew
clockwise.
COM mA A
V
Te mp
aEb
* METRAFLEX
Overbren-
gingsverhou-
ding
Transforma-
tion ratio
CLIP
Meetbereiken
Measuring
Ranges
Tang
Current
sensor
300
mV
3 V 30 V
1:1
1mV/1mA
0,3 A
3 A 30 A
WZ12C
1:10
1mV/10mA 3 A 30 A 300 A
WZ12B
Z201A/B
METRAFLEX
1:100
1mV/100mA
30 A
300
A
3000 A
Z202A
/B
METRAFLEX
1:1000
1 mV/1 A
300
A
3000
A
(30kA)
WZ12C
Z202A/B
Z203A/B,*
~
R
x
0035
.
0
A
AC
TRMS
A~
Hz
1:1000
0050
.
1
Hz
AC
1:1000
SETUP
Stroom
Current
0035
.
0
A
1:1000
0035
.
0
A
1:1000
A
A
SETUP
DC
AC
TRMS
DC
TRMS
FUNC
ENTER
FUNC
ENTER
R
i
~ 9 M
R
i
V
V
V~
Hz
R
x
0V !
!
000.00
M
M
300 k/3 M/30 M/300 M
Meetbereiken:
Measuring Ranges:
a-b
a-E
b-E
M
ISO
@100V
COM mA A
V
Temp
aEb
ab
aE
Eb
ISO
a-b
FUNC
ENTER
UISO ON / OFF
ZERO
ESC
POL / UISO
FUNC
ENTER
UISO ON / OFF
a-E
FUNC
ENTER
UISO ON / OFF
ZERO
ESC
POL / UISO
FUNC
ENTER
UISO ON / OFF
b-E
FUNC
ENTER
UISO ON / OFF
ZERO
ESC
POL / UISO
FUNC
ENTER
UISO ON / OFF
short leads
00
.
00
voor de meting
before measurem.
a
a
b
b
E
E
UISO
bAtt: 2.92 V
verSion: 1.00
dAtE: 13.09.06
tiME: 11:15:19
OCCUP:
100.0%
... InFo
tEMP ...SEt
1nfo
Submenu's / Parameters / Sub-menus / Parameters
rAtE 0:05:00
0.diSP
0000.0/0.0
A.diSP
bArG/Point
CLiP
OFF/1:1...1000
APoFF
10...59min/on
U_ISo 100 V
CAP 10 ... 500nF
r_SL 100...3,1K
,
bEEP
01... 90
irStb ir on/oFF
Addr 01...15
dAtE 13.09.
tiME 11:15
C
F
Hoofdmenu's / Main Menus
opvragen instellen instellen
read set set
... SEnd ... StorE ...
bevestigen
confirm
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
MEASURE
SETUP
0
20
.
00
V
DC
AC
TRMS
Meetbereik
Measuring Range
Meetfout / Measuring Error
Overbelastbaarheid
1)
Overload capacity
/
300 mV
(
0,5% + 3 D)
2)
1,5% + 3 D
(> 300 D)
600 V
DC
AC
eff
Sinus/
sine
continu
continuous
3V
(
0,5% + 1 D)
1,5% + 3 D
(> 100 D)
30 V
300 V
600 V
1 Hz ... 300,00 kHz (0,5% + 1 D) 600 V
3)
max. 10 s
/
300 mA (0,5% + 5 D)
1,5% + 5 D
(> 100 D)
0,3 A
continu
continuous
3mA
(0,5% + 3 D)30 mA
300 mA
1A(0,5% + 5 D) 1,6 A 5 min
1 Hz ... 30,00 kHz (0,5% + 1 D)
4)
(... % v.d. meetw. + ... D)
300 0,5 + 3
2)
600 V
DC
AC
eff/rms
Sinus/
sine
max. 10 s
3k
0,5 + 1
30 k
300 k
3M
30 M 2 + 5
R
SL
300 3 + 5
R
SL
3k 3 + 5
300 3 + 5
5,100 V 2 + 5
30 nF (1 % + 6 D)
2)
600 V
DC
AC
eff
Sinus/
sine
max. 10 s
300 nF
(1% + 6 D)3 F
30 F
300 F (5% + 6 D)
IP XY
(1e cijfer X)
(1
st
digit X)
Bescherming tegen
binnendringen van vaste
vreemde deeltjes
Protection against
foreign object entry
IP XY
(2e cijfer Y)
(2
nd
digit Y)
Bescherming tegen bin-
nendringen van water
Protection against the
penetration of water
5
Stofvrij
dust protected
4
Spatwater
splashing water
Zekering defect
0fuse
A
DC
Fuse defective
?
Zekering testen
Test Fuse
A
A
A~
Hz
!
!
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gossen Metrawatt METRAHIT T-COM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Gossen Metrawatt METRAHIT T-COM

Gossen Metrawatt METRAHIT T-COM Kurzanleitung - Deutsch, Englisch - 2 seiten

Gossen Metrawatt METRAHIT T-COM Bedienungsanleitung - Englisch - 72 seiten

Gossen Metrawatt METRAHIT T-COM Bedienungsanleitung - Holländisch - 72 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info