9 Measuring Low-Value Resistance (to 100 )
According to the regulations, measurement of low-value resistance at
protective conductors, earth conductors and bonding conductors must
be performed with (automatic) measuring voltage polarity reversal, or with
the flow of current in one direction (+ pole to PE), or the other (– pole to
PE).
Attention!
!
Low-value resistance may only be measured at voltage-free
objects.
Attention!
!
In order to be able to start the measurement, contact must first be
established between the test probes and the device under test.
If voltage is present at the device under test, or if resistance is greater
than 100  no measurement is performed.
Automatic Polarity Reversal – AUTOFunction
With automatic polarity reversal, the instrument performs measurement
first in one direction and then in the other, after the measuring sequence
has been started.
The largest measured resistance value is always displayed. This
presupposes that AUTO is displayed underneath R
LO
. If either of
the values RLO/+ or RLO/– is displayed instead of AUTO, press
the  key in the menu bar and then AUTO
Resistance values which do not demonstrate stabilized values until after
settling in, should not be measured with automatic polarity reversal.
Measurement with automatic polarity reversal may result in varying,
excessively high measured values and thus to an ambiguous read-out.
Measurement with + Pole to PE, or – Pole to PE
In order to determine whether or not test results are independent of the
direction of flow, measurement can be performed separately in both
directions. Press the  key in the menu bar to this end, and then either +
or – depending upon the desired direction of flow.
Differing results indicate that voltage is present at the device under test
(e.g. thermoelectromotive force or elemental voltage).
Measurement results may be distorted by parallel connected impedances
from load current circuits and equalizing current, especially in systems
equipped with “overcurrent protective devices” (formerly neutralization)
without a separate protective conductor. A change in resistance during
measurement (e.g. inductance), or poor contact may also result in
distorted measurements.
The following are examples of resistance values which may change during
measurement :
Resistance values for incandescent light bulbs due to warming
caused by test current
Resistance with an excessively high inductive component
In order to assure unambiguous measurement results, it is necessary to
recognize and eliminate any cause of error.
The instrument’s batteries are depleted rapidly during resistance
measurement. Only press the START key as long as necessary during
measurement with current flow in a single direction.
START
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gossen Metrawatt METRISO C wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Gossen Metrawatt METRISO C

Gossen Metrawatt METRISO C Bedienungsanleitung - Holländisch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info