590777
10
Zoom out
Zoom in
Vorherige Seite
1/96
Nächste Seite
10 GMC-I Messtechnik GmbH
Significance of Individual Parameters
Test Instrument On-Time
The period of time after which the test instrument is automatically
shut off can be selected here. This selection has a considerable
influence on the service life and the charging status of the batter-
ies.
On-Time for LCD Illumination
The period of time after which LCD illumination is automatically
shut off can be selected here. This selection has a considerable
influence on the service life and the charging status of the batter-
ies.
Submenu: Rotary Switch Balancing
Proceed as follows in order to precision adjust the rotary switch:
1 Press the TESTS Rotary Switch / Battery Test softkey in order to
access the rotary switch balancing menu.
2 Then press the softkey with the rotary switch symbol.
3 Turn the rotary switch clockwise to the next respective measuring
function (IDN first after SETUP).
4 Press the softkey which is assigned to the rotary switch at the LCD.
After pressing this softkey, the display is switched to the next mea-
suring function. Labeling in the LCD image must correspond to the
actual position of the rotary switch.
The
level bar in the LCD image of the rotary switch should be
located in the middle of the black field, and is supplemented at
the right-hand side with a number within a range of -1 to 101.
This value should be between 45 and 55. In the case of -1 or 101,
the position of rotary knob does not coincide with the measuring
function selected at the LCD.
5 If the displayed value is not within this range, readjust the
position by pressing the readjust softkey. A brief acoustic
signal acknowledges readjustment.
Note
If labeling in the LCD image of the rotary switch does not
correspond with its actual position, a continuous acous-
tic signal is generated as a warning when the readjust
softkey is pressed.
6 Return to point 2 and continue. Repeat this procedure until all
rotary switch functions have been tested, and if necessary
readjusted.
Press ESC in order to return to the main menu.
Submenu: Battery Level Query
If battery voltage has dropped to 8.0 V or less, the UL/RL LED lights
up red and an acoustic signal is generated as well.
Note
Measuring Sequence
If battery voltage drops to below 8.0 V
during the course of a measuring
sequence, this is indicated by means of
a pop-up window only. Measured val-
ues are invalid. The measurement results cannot be
saved to memory.
Press ESC in order to return to the main menu.
Attention!
!
Data and sequences are lost
when the language, the profile or
DB mode is changed, or if the in-
strument is reset to default val-
ues!
Back up your structures,
measurement data and se-
quences to a PC before
pressing the respective key.
The prompt window shown at
the right asks you to confirm
deletion.
User Interface Language (CULTURE)
Select the desired country setup with the appropriate country
code. Attention: all existing structures, data and sequences are de-
leted, see note above!
Profiles for Distributor Structures (PROFILES)
The profiles are laid out in
a tree structure. The tree
structure for the utilized
PC evaluation program
may differ from that of the
PROFITEST MASTER. For
this reason, the
PROFITEST MASTER pro-
vides the user with the
opportunity of adapting
this structure.
Selecting a suitable profile
determines which object
combinations are made
possible. For example,
this makes it possible to
create a distributor which is subordinate to another, or to save a
measurement to a given building.
Select the PC evaluation program you intend to use.
Attention: all existing structures, data and sequences are deleted,
see note above!
If you have not selected a suitable PC evalua-
tion program and, for example, if measured
value storage to the selected location within the
structure is not possible, the pop-up window
shown at the right appears.
Default Settings (GOME SETTING)
The test instrument is returned to its original default settings when
this key is activated.
Attention: all existing structures, data and sequences are deleted, see
note above!
Adjusting Brightness and Contrast
0a
0b
2
2
3c
3d
3e
3f
Return to previous menu
Increase brightness
Decrease brightness
Increase contrast
Decrease contrast
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

gossen-metrawatt-profitest--mxtra

Suche zurücksetzen

  • 1) Kann ich die Profitest Mxtra Oberfläche auf den Monitor darstellen..?
    2) Wie wird da eine Bluetooth Tastaur angeschlossen..? kann ich dann über das Pach Feld das Messgerät einstellen und die Funktionen wählen...? Eingereicht am 28-11-2022 16:37

    Antworten Frage melden
  • Wenn ich den Adapter nr 4 Prüfspitze L-PE zur des Schleifenwiderstandes kommt immer das symbol stopp mit 2 mal xx und so einer art sicherungssymbol . was bedeutet das ? Eingereicht am 14-10-2017 09:33

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gossen Metrawatt PROFITEST MXTRA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Gossen Metrawatt PROFITEST MXTRA

Gossen Metrawatt PROFITEST MXTRA Bedienungsanleitung - Holländisch - 92 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info