4 Initial Start-Up
4.1 Installing or Replacing the Battery Pack
Attention!
!
Before opening the battery compartment, disconnect the
instrument from the measuring circuit (mains) at all poles!
Note
See also section 18.2 on page 52 regarding the charging
procedure for the Compact Master Battery Pack (Z502H)
and concerning the Z502R charger.
If at all possible, use the Compact Master Battery Pack (Z502H) with
sealed cells which is available as an accessory. This ensures that the
complete set of rechargeable batteries is always replaced at the
same time and that all batteries are inserted with correct polarity,
in order to assure that they do not fail.
Only use commercially available rechargeable battery packs if they will
be externally recharged. The quality of these packs cannot be
checked and may result in overheating and thus deformation
under unfavorable conditions (when charging them in the instru-
ment).
Dispose of rechargeable battery packs or individual rechargeable
batteries in an environmentally sound fashion when their service
life has nearly expired (approx. 80% charging capacity).
Loosen the slotted screw for the rechargeable battery com-
partment lid on the back and remove the lid.
Remove the depleted rechargeable battery pack/holder.
Attention!
!
If the rechargeable battery holder is used:
Make sure that all of the batteries are inserted with cor-
rect polarity. If just one battery is inserted with reversed
polarity, it will not be recognized by the instrument and
may result in leakage from the batteries.
Individual rechargeable batteries may only be recharged
externally.
Insert the new rechargeable battery pack / loaded recharge-
able battery holder into the rechargeable battery compart-
ment.
The holder can only be inserted in its proper position.
Replace the lid and retighten the screw.
4.2 Switching the Instrument On/Off
The test instrument is switched on by pressing the ON/START key.
The menu which corresponds to the momentary selector switch
position is displayed.
The instrument can be switched off manually by simultaneously
pressing the MEM and HELP keys.
After the period of time selected in the SETUP menus has elapsed,
the instrument is switched off automatically (see “Device Set-
tings”, section 4.5).
4.3 (Rechargeable) Battery Test
If (rechargeable) battery voltage has fallen below the
allowable lower limit, the pictograph shown at the
right appears. “Low Batt!!!” is also displayed along with a
(rechargeable) battery symbol. The instrument does not function if
the batteries have been depleted excessively, and no display
appears.
4.4 Charging the Battery Pack in the Tester
Attention!
!
Use the Z502R charger in order to recharge the Compact
Master Battery Pack (Z502H) in the test instrument.
Make sure that the following conditions have been fulfilled be-
fore connecting the charger to the charging socket:
– The Compact Master Battery Pack (Z502H) has been
inserted, i.e. not a commercially available rechargeable
battery pack, individual batteries or non-rechargeable
batteries.
– The test instrument has been disconnected from the
measuring circuit at all poles.
– The instrument must remain off during charging.
Refer to section 18.2.1 with regard to charging a rechargeable
battery pack which has been inserted into the tester.
If the rechargeable batteries or battery pack have not been used
or recharged for a lengthy period of time (> 1 month), thus result-
ing in excessive depletion:
Observe the charging sequence (indicated by LEDs at the char-
ger) and initiate a second charging sequence if necessary (dis-
connect the charger from the mains and from the test instrument
to this end, and then reconnect it).
Please note that the system clock stops in this case and must be
set to the correct time after the instrument has been restarted.
BAT
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gossen Metrawatt Profitest Intro wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info