126 GMC-I Messtechnik GmbH
Technical Data
8 Technical Data
Func-
tion
Measured
Quantity
Measuring Range /
Nominal Range of
Use
Reso-
lution
Addi-
tional
Informa-
tion
Open-
Circuit
Voltage
U
0
Addi-
tional
Infor-
mation
Short-
circuit
current
I
K
Int.
Resis-
tance
R
I
Ref.
Resis-
tance
R
REF
Measuring
Uncertainty *
Intrinsic
Uncertainty *
Overload
Capacity
Value Time
DIN VDE 0701-0702 / IEC 62353 (VDE 0751-1) Tests
PE
resistance R PE
man: 1 ... 999 m 1 m
Electronic
fuse + fuse
link
4.0
4.5 V
AC TRMS
Where Isl
= 200
mA~
220 ...
270 mA
AC TRMS
——
10% rdg.
within a rage of
0.1 ... 10

where IP = 200 mA
(2.5% rdg. + 10 m
)
within a rage of
0.1 ... 10

where IP
= 200 mA
264 V
AC/DC
Cont.
man: 0.01
... 9.99 10 m
auto:
0.01
...
30.00

0.01 ... 3.30

0.1 ... 10.0
10 m
10 m
100 m
Insulation
resistance
R ISO
10 ... 300 k 10 k
Test
voltage:
100/200/
300/400/
500
V DC
U
N
< U <
1.2 U
N
Nominal
current
> 1 mA
where
R
ISO
=
500 k
2 mA
0.01 ... 100 M
:
10% rdg.
> 100 M
20% rdg.
where UP = 500 V
each
0.1 ... 30 M
:
(2.5% rdg. + 1 d)
> 30 M
(5% rdg. + 1 d)
where UP = 500 V
each
264 V
AC/DC
Cont.
0.01
... 3.0 M 10 k
0.1
... 30.0 M 100 k
1
... 300 M 1 M
Equivalent
leakage current
I AP
10 ... 300 A~
0.01
... 3.00 mA~
0.1
... 30.0 mA~
10 A
10
A
100 A
Test
voltage:
110, 220,
230, 240 V
AC
110 ... 240
V~
–15 /
+10%
Freq.
50, 60,
200, 400
Hz
< 1.5 mA
> 150
k
1 k
10
20
A
...
15 mA AC:
10% rdg.
>
15.0 mA AC: 
15% rdg.
20
A
...
15 mA AC:
(5% rdg. + 1 d)
>
15.0 mA AC:
(10% rdg. + 1 d)
264 V
AC/DC
Cont.
Direct methodt
I T
10 ... 300 A
0.01
... 3.00 mA at
0.1
... 30.00 mA at
10 A
10
A
Probe current monitoring:
Probe shutdown: I
C
> 10 mA~ (5 ms)
Residual current monitoring
Mains shutdown: I
D
> 10 mA~ (25 ms)
1 k
10
0.02 ... 10 mA at: 
10% rdg.
20
... 300 A at:
(5% rdg. + 1 d)
> 300 A at: (2.5%
rdg. + 1 d)
264 V
AC/DC
Cont.
Direct
methodt
I P
10 ... 300 A
0.01
... 3.00 mA at
10 A
10
A
Probe current monitoring:
Probe shutdown: I
PL
> 10 mA~ (5 ms)
Residual current monitoring
Mains shutdown: I
D
> 10 mA~ (25 ms)
1 k
10
0.01 ... 3 mA at: 
10% rdg.
10
... 300 A at:
(7.5% rdg. + 1 d)
0.30
... 3.00 mA at
±(2.5% rdg. + 1 d)
264 V
AC/DC
Cont.
Residual current
I PE
between L and
N
10 ... 300 A~
0.01
... 3.00 mA~
0.1
... 30.0 mA
10 A
10 A
100 A
= Protective conductor current, direct
Residual current monitoring
Mains shutdown: > 20 mA~ (25 ms)
0.5 ... 20.0 mA:
10% rdg.
20
... 300 A: (5%
rdg. + 1 d)
>
300 A:
(2.5% rdg. + 1 d)
264 V
AC/DC
Cont.
PE leakage
current
Direct I PE
between L and
N
10 ... 300 A
0.01
... 3.00 mA at
0.1
... 30.0 mA at
10 A
10 A
100 A
= Protective conductor current, direct
Residual current monitoring
Mains shutdown: > 20 mA~ (25 ms)
0.5 ... 20.0 mA:
10% rdg.
20
... 300 A: (5%
rdg. + 1 d)
>
300 A:
(2.5% rdg. + 1 d)
264 V
AC/DC
Cont.
Prot. conductor
current I PE with
current sensor
0.0 ... 100.0 mA 100 A
Via current sensor as optional accessory (sockets 3 and 4)
with a transformation ratio of 1 mV / 1 mA
In preparation
Depends upon current sensor
characteristics
126

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Gossen Metrawatt SECUSTAR FM wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info