505347
22
Zoom out
Zoom in
Vorherige Seite
1/35
Nächste Seite
Grandstream Networks, Inc. GXW410x User Manual Page 22 of 35
Firmware Version 1.3.4.13 Last Updated: 3/2012
T
ABLE 9: FXO LINE TEST TAB DEFINITIONS
Note: The user can only test the parameters for only one of the PSTN lines at the
same time. In all cases please enter the telephone numbers as if the lines were to
dial each other locally.
For the AC Impedance Test we only need to select the line to be tested by clicking
on the AC impedance box corresponding to that line, telephone numbers are
optional. Remember that the AC impedance test is usually used to reduce the echo
that might be present in the line.
For the CPT test (call progress tones) we will test current disconnect as well. You
will need 2 telephone numbers to perform the test. You can only perform the test on
one line (row) at the same time and it will be the one that has the box checked for
testing. This tested line will use another line connected to the gateway to perform
the test by calling into it, this is why you will have to enter the telephone number for
a second line to help with the test.
For CID detection you will need 2 telephone numbers to perform the test. You can
only perform the test on one line (row) at the same time and it will be the one that
has the box checked for testing. This tested line will use another line connected to
the gateway to perform the test by calling into it, this is why you will have to enter
the telephone number for a second line to help with the test.
To perform the test, please select the line you want to test and the desired test to be
performed. Enter the information for this line as well as a second line if necessary.
Then click on the update button and then reboot. Log back in and now you should
see the information for the line selected as well as the check box already marked
already there. Go ahead and start the test now, please wait a few minutes until the
test is done.
Notes:
It is not required to enter a telephone number when testing for impedance, as the
system does not place any actual calls for the test.
If you log into the Web Interface while the test is running will not interrupt the
process.
Line #
Enter the telephone (PSTN) number that corresponds to this line. Enter it as if you
were going to dial it locally.
AC Impedance
Select this box if you want to test for impedance on the line that is on the same row
as the checked box. Remember that you can only check one item at the same time.
CPT Detection
Select this box if you want to test for call progress tones and current disconnect
threshold on the line that is on the same row as the checked box. Remember that
you can only check one item at the same time.
External Numbe
r
Enter an external telephone (PSTN) number to be used as an auxiliary number for
the test. This is used only if we do not have at least 2 PSTN lines connected to the
gateway. This is only used for CPT and current disconnect threshold testing. In
order to use this function you will have to monitor the Syslog output. This is only
reserved for very advanced users.
External Call Timeout
This is the time the GXW will wait for the external telephone number to pick up
during the test.
Apply test results
automatically
Default is No. If selected on Yes, then all the results from the test will be applied
automatically. If you select No you will have to monitor the Syslog output. This is
only reserved for very advanced users.
Apply test results to all
ports
Default is No. If selected on Yes, then all the test results will be applied to all ports
on the gateway. If all the lines belong to the same service provider or PBX it will
make sense to apply the results to all ports.
22

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Grandstream GXW410x series wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info