Code 72 ALARM TIMER and Code 97
MIX-only Channel Stopwatch Stopwatch
Mix-only Channel Set-up Stopwatch
32
M
I
X
O
N
L
Y
C
H
n
o
Code 72 permits interrupting the normal direct signal
flow between the control function inlets and the
associated control channels at the outlet side. The
signal generators connected to the control function
inlets concerned will then affect the mixer inputs of
the channel in question, but not the allocated servo.
The latter can then be reached by mixers
programmed for their specific control channels. Using
this arrangement, it is possible to utilise the signal
generator and servo of one or more channels
independently of each other for optional special
functions.
It permits, for example in F3B model types to use
channel 1 via the dummy function of a special
functions mixer to operate “butterfly mode”, controlled
by the throttle/spoiler stick, provided spoilers have not
been installed.
In the case where spoilers have been installed and
“butterfly mode” with or without spoilers is to be
provided for experimentation purposes, a mixer can
be operated in normal mode. With the aid of code 33,
this connection can be turned on and off. The same
applies to other applications.
Any channel can be switched between normal and
mix-only mode by keys 1 9 . All channels can be
switch back to normal by pressing the CLEAR key.
The PROFI-ULTRASOFT-Module offers two
stopwatch functions.
1. Stopwatch with normal display (hours,
minutes and seconds).
2. Timer alert, with seconds display.
One of these options can be selected for each model
program.
A stopwatch, once programmed, will appear on the
lower line of the display each time the transmitter is
turned on, it does not need to be called over and over
again. Once triggered the stopwatch will continue to
run even when inputs are made during its operation
via the keyboard.
Stopwatch with normal display.
The stopwatch with normal display may be
programmed by allocating a switch to function “CLK”
using code 23. A prerequisite is that the alarm timer
(code 97) is not activated. The clock will then run as
long as the allocated switch is closed. Using the
CLEAR key it can be reset to 0.00.00 when not
running (if running the transmitter switches to list of
codes mode of operation). By this programmable
switch allocation, the stopwatch function may be
coupled with the tow hook, permitting the exact
duration of flight (starting from release of the tow-line)
to be recorded.
T
I
M
E
R
6
0
0
s
e
c
A
L
A
R
M
3
0
s
e
c
After calling code 97, the message “TIMER OFF” will
appear on the display. The timer is activated by the
INC or DEC key, whereby the stopwatch, possibly
programmed by code 23, will be turned off. The alarm
timer can be deactivated by the CLEAR key. Timer
run can be adjusted on the upper line of the display in
10 second increments using the INC and DEC
keys. In the lower line a point of time can be set
when, prior to the expiration of the return time, an
acoustic signal alerts the flyer. The arrow at the right
hand end of the display indicates which time can
currently be adjusted, and is moved by pressing the
TURN key.
After the set time has run down to 0, it is indicated by
a longer acoustic signal. The timer continues to run,
so that the time beyond 0 can be read.
Start/Stop instructions can be given by keys 2 and
3 respectively, or via an intermediate switch (order
No. 4160/11) connected to plug station CLK, or a kick
button (order No. 4144).
If a switch for the timer has been allocated by code
23, operation of the alarm timer will be performed
exclusively by that switch.
Acoustic Signal Sequence:
100s before zero: every 5 seconds
20s before zero: every 2 seconds
10s before zero: every second
0s Extended Signal
A + symbol on the display indicates that the time
shown is that beyond zero. The maximum timer
capacity is 900 seconds beyond zero.
32

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

graupner-mc18

Suche zurücksetzen

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Graupner MC18 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Graupner MC18

Graupner MC18 Bedienungsanleitung - Deutsch - 188 seiten

Graupner MC18 Bedienungsanleitung - Französisch - 58 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info