Pb manual program
In this program you can set the maximum permissible charge
current using the INC / DEC buttons, but only before you
connect the lead-acid battery for charging.
This setting only determines the top limit which the charger is
permitted to feed to the battery.
If the battery manufacturer states a low maximum charge current, then it is important to limit the charge
current to that value to avoid the charger setting a higher current if the battery appears to be willing
to accept charge.
The battery can then be connected to the charger and the charge process started: the unit starts
charging at 0.00 A and slowly raises the current until it reaches the set limit.
The charger constantly assesses the state of the battery during the charge process, and adjusts the
charge current to suit its condition.
The charge program automatically determines the number of cells (cell count) in the battery by measu-
ring its overall voltage.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
P b - C :
2 . 5 A
DECINC
+
-
14. Pb (lead-acid) programs (Output 1)
This program is designed for charging and discharging lead / sulphuric acid and lead / gel batteries with
nominal voltages of exactly 2, 4, 6 and 12 V (1, 2, 3 and 6 cells).
Caution: the charger will not recognize lead-acid batteries with other nominal voltages, and such bat-
teries must not be connected to it.
Lead-acid batteries behave entirely differently to Ni-Cd and Ni-MH batteries. Lead-acid batteries can
only deliver relatively low currents relative to their capacity, and similar restrictions very defi nitely apply
to charging. Manufacturers usually state 14 to 16 hours for achieving nominal capacity when rechar-
ging at the normal charge current. The „normal“ charge current is defi ned as one tenth of the battery’s
nominal capacity. Example: battery capacity = 12 Ah —> normal charge current = 1.2 A. In contrast
to Ni-Cd and Ni-MH batteries, lead-acid chargers generally monitor the battery’s voltage in order to
determine when it is fully charged.
Caution: lead-acid batteries cannot and must not be fast-charged! Always select the charge
current which the battery manufacturer recommends. Please also bear in mind that the nominal
capacity (i.e. useful life) of a lead-acid battery is very quickly compromised by incorrect handling, in-
cluding overcharging, repeated 100% discharges and, in particular, deep discharging. The magnitude
of the charge / discharge currents is also crucial to the actual battery capacity which can be exploited,
i.e. the higher the current, the lower the capacity which the battery can deliver.
The values selected in the user settings for charge termination delay and safety timer have no effect
in the Pb charge programs.
Pb
MANUAL-
program
Pb
discharge
program
MODE MODE
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
P b m a n u a l
2 sec.
44

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Graupner ULTRA TRIO PLUS 16 - 6469 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info