Use only original spare parts and accessories. The use of other
parts will result in voiding the warranty and the CE marking, and
could cause injury.
The filter head must be replaced after 5 years.
Technical data cooler/carbonator electrical data:
Connection: Wall socket with earth wire,
protected via a 10 A fuse
Voltage supply: 230 V AC / 50 Hz
Max. power consumption: 240 W
Type of protection: IP 21
Relative air humidity: max. 80%
Refrigerant: 0.040 kg - R600a
Safety shut-off of pump: approx. 4:30 min
Operating pressure: min. 0,2 MPa - max. 1 MPa
•Max. CO
2 inlet pressure: 0.48 MPa
Max. refrigerant pressure: 3.0 MPa
WLAN: 2,4 GHz, IEEE 802.11 b/g/n/e/i
Bluetooth: v4.2 BLE
Sanitary data:
Cooler/carbonator cooled water capacity: 1.4 l
Operating pressure: max. 0.6 MPa
Flow rate at 0.3 MPa flow pressure: approx. 2 l/min
Ambient temperature: 4 – 32 °C
Temperature
– Cooler/carbonator water inlet: max. 20 °C
– Cooled water temperature: approx. 5 – 10 °C
Sound pressure level LpA (frestanding): 50 ± 4 dB
Adjustable bypass, factory setting: 2
Filter capacity Bypass Position 2
(Carbonate hardness 17 - 24 °KH): max. 600 litres
corresponds to max. 12 months
Water connection
– Cooler/carbonator: cold - blue
Electrical test data:
Software class: A
Contamination class: 2
Rated surge voltage: 2,500 V
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
Technical data fitting:
Flow pressure: 0.2 – 0.9 MPa
Operating pressure: max. 1 MPa
Test pressure: 1.6 MPa
To comply with noise levels if static pressure exceeds 5 bar, a
pressure reducing valve must be fitted.
Avoid major pressure differences between hot and cold water
supply.
Flow rate at 3 bar flow pressure: approx. 7 l/min
Temperature
– Hot water inlet: max. 70 °C
– Recommended (energy saving): 60 °C
Water connection: cold - right
hot - left
Thermical disinfektion of the fitting is possible.
GROHE ONDUS app and connection to the internet
A GROHE Blue cooler connected to the internet via Wi-Fi can be
integrated and configured in the GROHE ONDUS app. This app
can be used to deliver messages in the form of push notifications.
A WLAN router with internet access
(2.4 GHz, IEEE 802.11b/g/n) is required.
Only WLAN channels 1 11 can be used.
Installation of the app:
If the app or the device firmware requires updating, the smartphone
must be located in the immediate vicinity of the GROHE Blue
cooler. In this way, possible interruptions in function can be
controlled and rectified.
Operating conditions
Interference sources
The transmitter/receiver unit operates in the ISM frequency band
(2.4 GHz). Installation in proximity to devices with the same
frequency band (e.g. WLAN devices, HF components, etc.
[observe manufacturer documentation!]) should be avoided.
Obstructions/barriers
Wireless reception can be impaired and interrupted under
unfavourable surrounding conditions, in buildings/rooms with
reinforced concrete walls, steel and iron frames or in proximity to
obstacles (e.g. furniture) made of metal. Where necessary, a
WLAN repeater must be connected to the main router in order to
increase the range of the radio signal.
Installation and commissioning
GROHE recommends a depth of min. 510 mm for
the cabinet.
Flush pipes thoroughly before and after installation
(observe EN 806)!
Adjust bypass of filterhead according to local carbonate
hardness and connect filter cartridge.
The carbonate hardness can be tested by using the enclosed test
strip or the relevant water supplier can provide information on the
carbonate hardness.
The fitting has a system-related run-on time of approx. 1 s.
Note: Make sure that the water inlet hose does not come loose
by movement when installing the cooler.
When transporting or installing the cooler/carbonator,
cooling fluid may have run into the lines.
In order to ensure that the cooling fluid has run back, the
cooler/carbonator may only be installed following a pause
of 24 hours.
Display:
In the inactive state, the remaining filter capacity is displayed in per
cent.
When carbonate hardness ≤9° the use of activated carbon
filter (Order no.: 40 547 001) is recommended.
The cooler/carbonator of the GROHE Blue® fitting is set for
operation with the S size filter cartridge (Prod no.: 40 404 001) at
the factory.
For operation with other filter cartridges the cooler/carbonator must
be set out.
Apple: Android:
24
25

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Grohe 31326 Blue wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info