Nächste Seite
7
Display and setting of carbonate hardness on cooler/
carbonator, see table column B on fold-out page IV and
Fig. [27].
c button for carbonate hardness adjustment:
• Press the c button once:
The display switches from the remaining filter capacity to the
value currently set for the carbonate hardness.
• Keep the c button pressed:
After approx. 3 seconds, the value currently set for the
carbonate hardness starts to flash.
• Release the c button within the next 10 seconds:
The value currently set for the carbonate hardness starts
to flash.
• Press the c button and select the required value:
- C1: carbonate hardness 25 - 35 (bypass 20%)
- C2: carbonate hardness 18 - 24 (bypass 30%)
- Factory setting:
C3: carbonate hardness 14 - 17 (bypass 40%)
- C4: carbonate hardness 12 - 13 (bypass 50%)
- C5: carbonate hardness 10 - 11 (bypass 60%)
- C6: carbonate hardness 7 - 9 (bypass 70%)
Press and hold the c button at the required value
for 3 seconds:
The display of the value switches from flashing to
continuous illumination and the value is set.
• Release the c button:
The remaining filter capacity is displayed again:
The litre capacity of the cartridge varies according to the water
hardness set and the size of the cartridge, see table on
fold-out page IV.
The cooler/carbonator of the GROHE Blue
®
fitting is set for
operation with the 600 litre filter cartridge (Prod no.: 40 404)
at the factory.
For operation with the 3,000 litre filter cartridge (Prod. no.: 40 412)
or 1,500 litre filter cartridge (Prod. no.: 40 430), the cooler/
carbonator must be adapted.
Set the filter size, see Fig. [27].
U button for filter size selection:
• Press U button once.
The display switches from the remaining filter capacity to the
value currently set for the filter size.
• Keep the U button pressed:
After approx. 3 seconds, the value currently set for the filter
size starts to flash.
• Release the U button within the next 10 seconds:
The value currently set for the filter size starts to flash.
• Press the U button and select the filter size:
- F1: 600 litres
- F2: 1,500 litres
- F3: 3,000 litres
Press and hold the U button at the required value
for 3 seconds:
The display of the value for the filter size switches from
flashing to continuous illumination and the filter size is set.
• Release the U button:
The remaining filter capacity is displayed again:
The fitting with cooler/carbonator is now fully installed and
ready for operation.
Note: The various filter cartridges can be ordered at
www.grohe.com.
Maintenance
Resetting filter capacity after changing filter cartridge, see
fold-out page IV, Fig. [27].
button for filter replacement reset:
The remaining filter capacity is displayed:
• Press button
The display switches from the remaining filter capacity to rF.
• Keep the button pressed:
After approx. 3 seconds, rF starts to flash.
• Release the button within the next 10 seconds and press
again:
rF flashes first and then illuminates continuously.
• Release the button:
The remaining filter capacity is reset and then displayed
again.
Restore factory settings, see Fig. [27].
Reset Uc buttons to factory settings:
• Press the Uc buttons simultaneously:
The display switches from the remaining filter capacity
to PA.
• Keep the Uc button pressed:
After approx. 3 seconds, PA starts to flash.
• Release the Uc buttons within the next 10 seconds:
First PA flashes, HC lights up and fitting and cooler/
carbonator must be synchronised with one another.
Close handle and wait until the display in the handle
illuminates green.
Open handle fully until display in handle flashes green and
water runs.
• Close handle.
The remaining filter capacity is displayed:
Important:
Risk of damage:
Always disconnect the power supply and interrupt the
CO
2
supply before carrying out maintenance work on the
system. The plug-in connector can then be disconnected,
see fold-out page III, Fig. [24].
Inspect and clean all components and replace if necessary.
I. Cartridge, see fold-out page IV, Fig. [29].
Assemble in reverse order. When installing the cartridge,
ensure that the seals are correctly seated. Replace screw
coupling and tighten.
II. Headpart, see fold-out page IV, Fig. [30].
Assemble in reverse order. Note the installation position of the
stop and cable.
III. Mousseur (64 374), see fold-out page I.
Assemble in reverse order.
IV. Cleaning cooler/carbonator
For hygiene reasons, the cooler/carbonator must be cleaned
once a year. Cleaning must be performed before changing the
cartridge, in order to prevent contamination of the replacement
filter cartridge.
Note: The cleaning kit (Prod. no.: 40 434) can be ordered at
www.grohe.com.
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

grohe-blue-chilled-and-sparkling-system

Suche zurücksetzen

  • Ich habe den aktivkohlefilter gewechselt und nachdem er 99 anzeigte und 12 h funktionierte, blinkt er nun rot und zeigt E1. Ich soll die Absperrventile öffnen- was bedeutet das ? Eingereicht am 14-3-2022 12:54

    Antworten Frage melden
  • Wie schließe ich den schwarzen und blauen Schlauch an? Eingereicht am 14-8-2020 18:33

    Antworten Frage melden
  • Hallo,wir haben leider die Gasflasche zu spät im Vorgang abgemacht, nun blinkt C4 im Reinigungszyklus schon lange. Geht das irgendwann weiter, oder müssen wir von vorne starten? Eingereicht am 6-10-2019 18:32

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Grohe Blue Chilled and Sparkling system wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Grohe Blue Chilled and Sparkling system

Grohe Blue Chilled and Sparkling system Installationsanweisung - Englisch - 42 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info